Factors influencing the results of air samplers in closed, air-conditioned patient rooms—a numerical study

被引:0
作者
Ernst, Christian [1 ]
Heinrich, Martin [1 ]
Schwarze, Rüdiger [1 ]
机构
[1] Institute for Mechanics and Fluid Dynamics, TU Bergakademie Freiberg, Lampadiusstraße 4, Saxony, Freiberg
关键词
Aerosol distribution; Air sampling; CFD; Droplet evaporation; ILES; Patient room; SARS-CoV-2;
D O I
10.1007/s11356-025-36036-9
中图分类号
学科分类号
摘要
Several air sampling studies have been conducted to assess the risk of airborne transmission since the outbreak of SARS-CoV-2 in late 2019. However, differences in sampler positioning and positive collection results in more distant locations suggest an interaction between the sampler and the indoor air flow, altering the aerosol distribution. This study aims to investigate this influence by studying multiple collector positions, patient exhalation modes, and two ventilation setups in a 3D simulation model using implicit large-eddy simulations along with evaporative Lagrangian particles. The results of this study show a higher total aerosol particle amount in the patient room with the deployment of a sampling device, possibly increasing infection risk for medical personal during and shortly after a sampling procedure. Furthermore, the variation of the collector position reveals an impact on the sampling yield, thus rendering even more distant positions viable and potentially beneficial in terms of maintaining sampler performance and increasing patient comfort. Moreover, the influence of ventilation was investigated suggesting the deactivation to increase aerosol concentration during sampling campaigns for efficient sampling. Additionally, results indicate an impact on room flow by air samplers and subsequent sampling yield, potentially necessitating reassessments of conclusions drawn from previous sampler studies. Finally, it can be concluded that future air sampling campaigns, which are preliminarily assessed using numerical simulation, could benefit from advantageous positioning to aid sampling success. © The Author(s) 2025.
引用
收藏
页码:7680 / 7691
页数:11
相关论文
共 37 条
[1]  
Ang A.X.Y., Luhung I., Ahidjo B.A., Et al., Airborne SARS-CoV-2 surveillance in hospital environment using high-flowrate air samplers and its comparison to surface sampling, Indoor Air, 32, 1, (2022)
[2]  
Archer J., McCarthy L.P., Symons H.E., Comparing aerosol number and mass exhalation rates from children and adults during breathing, speaking and singing, Interface Focus, 12, 2, (2022)
[3]  
Ayuso S.A., Soriano I.S., Augenstein V.A., Et al., The aerosolization of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2): phase I, J Surg Res, 274, pp. 108-115, (2022)
[4]  
Baig T.A., Zhang M., Smith B.L., Et al., Environmental effects on viable virus transport and resuspension in ventilation airflow, Viruses, 14, 3, (2022)
[5]  
Beaussier M., Vanoli E., Zadegan F., Et al., Aerodynamic analysis of hospital ventilation according to seasonal variations. A simulation approach to prevent airborne viral transmission pathway during Covid-19 pandemic, Environ Int, 158, (2022)
[6]  
Celani A., Falkovich G., Mazzino A., Et al., Droplet condensation in turbulent flows, Europhys Lett (EPL), 70, 6, pp. 775-781, (2005)
[7]  
Cheng V.C.C., Wong S.C., Chan V.W.M., Et al., Air and environmental sampling for SARS-CoV-2 around hospitalized patients with coronavirus disease 2019 (COVID-19), Infect Control Hosp Epidemiol, 41, 11, pp. 1258-1265, (2020)
[8]  
Chia P.Y., Coleman K.K., Tan Y.K., Et al., Detection of air and surface contamination by SARS-CoV-2 in hospital rooms of infected patients, Nat Commun, 11, 1, (2020)
[9]  
Dao H.T., Kim K.S., Behavior of cough droplets emitted from COVID-19 patient in hospital isolation room with different ventilation configurations, Build Environ, 209, (2022)
[10]  
da Silva P.G., Goncalves J., Lopes A.I.B., Et al., Evidence of air and surface contamination with SARS-CoV-2 in a major hospital in Portugal, Int J Environ Res Public Health, 19, 1, (2022)