Penetrating fixation device versus fibrin sealant for mesh fixation in laparoscopic repair of ventral hernia: a randomized controlled trial

被引:0
作者
Bhattacharjee, Hemanga Kumar [1 ]
Anand, Vishal [1 ]
Mithun, N. K. [1 ]
Mishra, Ashwani Kumar [2 ]
Baksi, Aditya [1 ]
Joshi, Mohit [1 ]
Parshad, Rajinder [1 ]
机构
[1] All India Inst Med Sci, Dept Surg Disciplines, New Delhi 110029, India
[2] All India Inst Med Sci AIIMS, Natl Drug Dependence Treatment Ctr NDDTC, Biostat, New Delhi 110029, India
关键词
Ventral hernia; Mesh fixation; Laparoscopic; Glue fixation; Recurrence; Postoperative pain; CLINICAL-TRIAL; METAANALYSIS; PAIN; TACKS; GLUE;
D O I
10.1007/s10029-025-03294-y
中图分类号
R61 [外科手术学];
学科分类号
摘要
PurposePost-operative pain following intra peritoneal onlay mesh (IPOM) repair of ventral hernia is commonly attributed to mechanical fixation devices. Fibrin sealant is a novel technique of mesh fixation purported to cause less pain. The aim of this study was to compare postoperative pain in these two methods of mesh fixation.MethodsThis was a double-blinded, randomized controlled trial. Eighty patients with primary ventral hernia underwent laparoscopic IPOM repair using PROCEED (TM) mesh, which was fixed with either mechanical fixation device, SECURESTRAP (TM) (MF group) or fibrin sealant, TISSEEL (TM) (FS group). Primary end point was postoperative pain at rest and movement on a Visual Analogue Scale (VAS) of 0-10. Operative time, recurrence, seroma and quality of life (QoL) were secondary outcomes. Patients were followed up for one year.ResultsThere was no significant difference in pain score at 12 h, 24 h, 7 days, 1, 3 and 12 months between the groups, except pain on movement, which was significantly less in the FS group on the seventh day (median VAS 3 vs. 2, p = 0.01). Mean operative time was 8 min longer in the FS group (p = 0.001). Two patients in the FS and none in the MF group had recurrence at one year (p = 0.18). Seroma formation, postoperative QoL and patient satisfaction scores were similar in both groups.ConclusionsUse of fibrin sealant for mesh fixation does not provide significant advantage over mechanical fixation in laparoscopic IPOM repair.
引用
收藏
页数:11
相关论文
共 25 条
  • [1] A prospective randomized study comparing suture mesh fixation versus tacker mesh fixation for laparoscopic repair of incisional and ventral hernias
    Bansal, Virinder Kumar
    Misra, Mahesh C.
    Kumar, Subodh
    Rao, Y. Keerthi
    Singhal, Paras
    Goswami, Amit
    Guleria, Sandeep
    Arora, M. K.
    Chabra, Anjolie
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (05): : 1431 - 1438
  • [2] Laparoscopic IPOM technique
    Berger, D.
    [J]. CHIRURG, 2010, 81 (03): : 211 - 215
  • [3] Multiple uses of fibrin sealant for nervous system treatment following injury and disease
    Biscola, Natalia Perussi
    Cartarozzi, Luciana Politti
    Ulian-Benitez, Suzana
    Barbizan, Roberta
    Castro, Mateus Vidigal
    Spejo, Aline Barroso
    Ferreira, Rui Seabra, Jr.
    Barraviera, Benedito
    Rodrigues Oliveira, Alexandre Leite
    [J]. JOURNAL OF VENOMOUS ANIMALS AND TOXINS INCLUDING TROPICAL DISEASES, 2017, 23 (01):
  • [4] Update of Guidelines for laparoscopic treatment of ventral and incisional abdominal wall hernias (International Endohernia Society (IEHS)): Part B
    Bittner, R.
    Bain, K.
    Bansal, V. K.
    Berrevoet, F.
    Bingener-Casey, J.
    Chen, D.
    Chen, J.
    Chowbey, P.
    Dietz, U. A.
    de Beaux, A.
    Ferzli, G.
    Fortelny, R.
    Hoffmann, H.
    Iskander, M.
    Li, Z.
    Jorgensen, L. N.
    Khullar, R.
    Kirchhoff, P.
    Koeckerling, F.
    Kukleta, J.
    LeBlanc, K.
    Li, J.
    Lomanto, D.
    Mayer, F.
    Meytes, V
    Misra, M.
    Morales-Conde, S.
    Niebuhr, H.
    Radvinsky, D.
    Ramshaw, B.
    Ranev, D.
    Reinpold, W.
    Sharma, A.
    Schrittwieser, R.
    Stechemesser, B.
    Sutedja, B.
    Tang, J.
    Warren, J.
    Weyhe, D.
    Wiegering, A.
    Woeste, G.
    Yao, Q.
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2019, 33 (11): : 3511 - 3549
  • [5] An update on topical haemostatic agents in liver surgery: systematic review and meta analysis
    Brustia, Raffaele
    Granger, Benjamin
    Scatton, Olivier
    [J]. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2016, 23 (10) : 609 - 621
  • [6] The Impact of Mesh Fixation With a Collagen-Fibrin Sealant in a Murine Ventral Hernia Model
    Chen, Ying
    Hansen, Kristine Eraker-Aasland
    Spasojevic, Milan
    Naesgaard, Jens-Marius
    Ignjatovic, Dejan
    [J]. SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2014, 24 (02) : 140 - 144
  • [7] Fibrin sealant for mesh fixation in laparoscopic umbilical hernia repair: 1-year results of a randomized controlled double-blinded study
    Eriksen, J. R.
    Bisgaard, T.
    Assaadzadeh, S.
    Jorgensen, L. N.
    Rosenberg, J.
    [J]. HERNIA, 2013, 17 (04) : 511 - 514
  • [8] Randomized clinical trial of fibrin sealant versus titanium tacks for mesh fixation in laparoscopic umbilical hernia repair
    Eriksen, J. R.
    Bisgaard, T.
    Assaadzadeh, S.
    Jorgensen, L. Nannestad
    Rosenberg, J.
    [J]. BRITISH JOURNAL OF SURGERY, 2011, 98 (11) : 1537 - 1545
  • [9] Pain, quality of life and recovery after laparoscopic ventral hernia repair
    Eriksen, J. R.
    Poornoroozy, P.
    Jorgensen, L. N.
    Jacobsen, B.
    Friis-Andersen, H. U.
    Rosenberg, J.
    [J]. HERNIA, 2009, 13 (01) : 13 - 21
  • [10] Eriksen JR, 2011, DAN MED BULL, V58