Empowering grid intelligence: a comprehensive review on optimal placement and diverse applications of synchronized phasor measurement units in modern power systems

被引:0
|
作者
Sneha, Boya [1 ]
Babu, Rohit [1 ]
Mahapatra, Sheila [1 ]
机构
[1] Alliance Univ, Alliance Coll Engn & Design, Dept Elect & Elect Engn, Bengaluru 526106, Karnataka, India
关键词
Observability; Global positioning system; Optimal PMU placement; Phasor measurement unit; Synchronized measurements; OPTIMAL PMU PLACEMENT; BAD DATA DETECTION; NUMERICAL OBSERVABILITY; NETWORK OBSERVABILITY; STATE ESTIMATION; MULTISTAGE PLACEMENT; CHANNEL CAPACITY; ALGORITHM; PROTECTION; FREQUENCY;
D O I
10.1007/s13198-024-02637-9
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Deregulation has allowed for more effective power generation, technical advancements, and eventually reduced retail pricing, which has caused the electric power business to go through a number of changes in recent decades. In this context, the development of sustainable instruments for the supervision and management of power networks has become a crescively pressing necessity due to the presence of dynamic phenomena inside such systems. The state estimator is an excellent instrument that can be used for the careful monitoring of the circumstances of their operations. The conventional estimators make use of measurements taken in real-time by means of a SCADA system. Remote terminal units (RTUs), which are often deployed in high-voltage substations, are the devices that are responsible for providing these measurements. Because of the technological challenges that are related to the synchronization of measurements at RTUs, it is impracticable to supervise the bus voltages phase angles in a comprehensive manner. The global positioning system (GPS), which also helped contribute to the development of phasor measurement units (PMUs), made it more simpler and less time-consuming to deal with these difficulties. The voltage and current phasor quantification may be obtained with a high level of accuracy using a PMU unit that is fitted with a GPS receiver. These measurements are made in relation to a standard reference phase angle. An introduction to the PMU technology and a discussion on how PMUs should ideally be distributed across a power network is offered in the initial section of this research study. There is a focus on the most important problems with the implementation and functioning of PMUs, and there is also an inquiry into commercialization penetration in the power markets. In the succeeding section of the study, a broad variety of approaches relating to the selection of the judicious placement of PMUs are presented, along with an algorithmic process for determining the optimum set of PMUs that are necessary for complete observability.
引用
收藏
页码:622 / 650
页数:29
相关论文
共 41 条
  • [21] Optimal phasor measurement units placement considering multi-objectives in shipboard power system
    Wang, J. (wang0600519@sina.com), 1600, Science Press (38):
  • [22] Directions of Application of Phasor Measurement Units for Control and Monitoring of Modern Power Systems: A State-of-the-Art Review
    Pazderin, Andrey
    Zicmane, Inga
    Senyuk, Mihail
    Gubin, Pavel
    Polyakov, Ilya
    Mukhlynin, Nikita
    Safaraliev, Murodbek
    Kamalov, Firuz
    ENERGIES, 2023, 16 (17)
  • [23] Phasor Measurement Unit Integration: A Review on Optimal PMU Placement Methods in Power System
    Noureen, Subrina Sultana
    Roy, Vishwajit
    Bayne, Stephen B.
    2017 IEEE REGION 10 HUMANITARIAN TECHNOLOGY CONFERENCE (R10-HTC), 2017, : 328 - 332
  • [24] Dynamic equivalent state estimation for multi-area power systems with synchronized phasor measurement units
    Vahidnia, Arash
    Ledwich, Gerard
    Palmer, Edward
    Ghosh, Arindam
    ELECTRIC POWER SYSTEMS RESEARCH, 2013, 96 : 170 - 176
  • [25] An innovative deterministic algorithm for optimal placement of micro phasor measurement units in radial electricity distribution systems
    Manghutay, Aref Gholizadeh
    Naderi, Mehdi Salay
    Fathi, Seyed Hamid
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2022, 41 (01) : 550 - 573
  • [26] Optimal phasor measurement units placement for full observability of power system using improved particle swarm optimisation
    Saleh, Alaa Abdelwahab
    Adail, Ahmed S.
    Wadoud, Amir A.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (07) : 1794 - 1800
  • [27] Allocation of synchronized phasor measurement units for power grid observability using advanced binary accelerated particle swarm optimization approach
    Rohit Babu
    Saurav Raj
    Sheila Mahapatra
    Journal of Electrical Systems and Information Technology, 10 (1)
  • [28] Cost-Effective Placement of Phasor Measurement Units to Defend against False Data Injection Attacks on Power Grid
    Bae, Junhyung
    ENERGIES, 2020, 13 (15)
  • [29] Optimal placement of phasor measurement units to attain power system observability utilizing an upgraded binary harmony search algorithm
    Nazari-Heris M.
    Mohammadi-Ivatloo B.
    Energy Syst., 2 (201-220): : 201 - 220
  • [30] A comprehensive review of FACTS devices in modern power systems: Addressing power quality, optimal placement, and stability with renewable energy penetration
    Alajrash, Ban H.
    Salem, Mohamed
    Swadi, Mahmood
    Senjyu, Tomonobu
    Kamarol, Mohamad
    Motahhir, Saad
    ENERGY REPORTS, 2024, 11 : 5350 - 5371