Meta-analysis of RCTs on the safety of non-fixation of mesh in TAPP inguinal hernia repair: an updated meta-analysis

被引:0
作者
Jiang, Tao [1 ]
Zhang, Chen [2 ,4 ]
Wang, Xiao-Ling [3 ]
Yue, Da-Chun [4 ]
Yuan, Xiao-Ping [4 ]
Wang, Deng-Chao [1 ]
机构
[1] Zigong Fourth Peoples Hosp, Dept Gen Surg, Zigong 643000, Sichuan, Peoples R China
[2] Zigong Fourth Peoples Hosp, Dept Trauma Ctr, Zigong 643000, Sichuan, Peoples R China
[3] Sichuan Univ Sci & Engn, Sch Comp Sci & Engn, Dept Network Engn, Zigong 643000, Sichuan, Peoples R China
[4] Peoples Hosp Pingchang Cty, Dept Orthoped, Pingchang 636400, Sichuan, Peoples R China
关键词
Inguinal hernia; TAPP; Mesh; Meta-analysis; NONFIXATION; TRIALS;
D O I
10.1186/s12893-024-02628-4
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective This meta-analysis aims to compare the clinical efficacy of mesh non-fixation and fixation in laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair, systematically evaluating the application value of the mesh non-fixation technique in clinical settings. Methods A computerized search of PubMed, Embase, Cochrane Library, Web of Science, and ClinicalTrials.gov databases was conducted to identify randomized controlled trials (RCTs) comparing mesh non-fixation and fixation in TAPP inguinal hernia repair. Meta-analysis was performed using RevMan 5.3 software, and the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) evidence grading system was employed for outcome quality assessment. Publication bias analysis was performed using Begg's test. A trial sequential analysis (TSA) was performed using TSA 0.9.5.10 Beta software. Results A total of nine RCTs involving 1,879 inguinal hernia patients were included. Meta-analysis results demonstrated that, compared to the fixation group, the non-fixation group exhibited significantly lower seroma occurrence rate [RR = 0.43, 95% CI (0.20, 0.89), P = 0.02, heterogeneity P = 0.28, I-2=22%], Visual Analog Scale (VAS) pain score at 6 months postoperatively [MD=-0.21, 95% CI (-0.29, -0.12), P < 0.00001, heterogeneity P = 0.34, I-2=0%], and cost [MD=-3.23 thousand yuan, 95% CI (-4.26, -2.19), P < 0.00001, heterogeneity P = 0.0003, I-2=92%]. There were no statistically significant differences in overall complication rate [RR = 0.88, 95% CI (0.62, 1.23), P = 0.45, heterogeneity P = 0.11, I-2=44%], overall infection event rate [RR = 0.96, 95% CI (0.36, 2.56), P = 0.93, heterogeneity P = 0.62, I-2=0%] and recurrence rate [RR = 0.75, 95% CI (0.28, 1.99), P = 0.56, heterogeneity P = 0.44, I-2=0%] between the two groups. The results of the TSA indicated that the observed lower seroma occurrence rate in the non-fixation group compared to the fixation group requires further validation through the inclusion of additional RCTs. Conclusion Mesh non-fixation in TAPP inguinal hernia repair is deemed safe and does not elevate the risk of hernia recurrence. However, given certain limitations in this study, future comprehensive and reliable validation will require further multicenter, high-quality, large-sample double-blind RCTs.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Meta-analysis of randomized controlled trials comparing lightweight and heavyweight mesh for Lichtenstein inguinal hernia repair
    Uzzaman, M. M.
    Ratnasingham, K.
    Ashraf, N.
    HERNIA, 2012, 16 (05) : 505 - 518
  • [32] Meta-analysis of randomized controlled trials comparing lightweight and heavyweight mesh for Lichtenstein inguinal hernia repair
    M. M. Uzzaman
    K. Ratnasingham
    N. Ashraf
    Hernia, 2012, 16 : 505 - 518
  • [33] A meta-analysis of randomized controlled trials of fixation versus nonfixation of mesh in laparoscopic total extraperitoneal inguinal hernia repair
    Yuan Jun Teng
    Shu Mei Pan
    Ya Li Liu
    Ke Hu Yang
    You Cheng Zhang
    Jin Hui Tian
    Jian Xu Han
    Surgical Endoscopy, 2011, 25 : 2849 - 2858
  • [34] Comparison of mesh fixation and non-fixation in laparoscopic totally extraperitoneal inguinal hernia repair
    Buyukasik, K.
    Ari, A.
    Akce, B.
    Tatar, C.
    Segmen, O.
    Bektas, H.
    HERNIA, 2017, 21 (04) : 543 - 548
  • [35] Meta-analysis of mesh-plug repair and Lichtenstein repair in the treatment of primary inguinal hernia
    Miao Yu
    Wen-Xian Xie
    Sheng Li
    Deng-Chao Wang
    Li-Yan Huang
    Updates in Surgery, 2021, 73 : 1297 - 1306
  • [36] Meta-analysis of mesh-plug repair and Lichtenstein repair in the treatment of primary inguinal hernia
    Yu, Miao
    Xie, Wen-Xian
    Li, Sheng
    Wang, Deng-Chao
    Huang, Li-Yan
    UPDATES IN SURGERY, 2021, 73 (04) : 1297 - 1306
  • [37] Outcomes on mesh fixation vs non-fixation in laparoscopic totally extra peritoneal inguinal hernia repair: a comparative study
    Nahid, Abu Kamal
    Rahman, Sanjida
    Veerapatherar, Keerthanaa
    Fernandes, Roland
    TURKISH JOURNAL OF SURGERY, 2021, 37 (01) : 1 - 5
  • [38] The comparison of self-gripping mesh and conventional mesh in laparoscopic inguinal hernia repair: the results of meta-analysis
    Wang, Dianchen
    Jiang, Jianwu
    Fu, Yang
    Qu, Pan
    UPDATES IN SURGERY, 2022, 74 (03) : 857 - 863
  • [39] The comparison of self-gripping mesh and conventional mesh in laparoscopic inguinal hernia repair: the results of meta-analysis
    Dianchen Wang
    Jianwu Jiang
    Yang Fu
    Pan Qu
    Updates in Surgery, 2022, 74 : 857 - 863
  • [40] The Comparison of Self-Gripping Mesh and Sutured Mesh in Open Inguinal Hernia Repair The Results of Meta-analysis
    Li, Junsheng
    Ji, Zhenling
    Li, Yinxiang
    ANNALS OF SURGERY, 2014, 259 (06) : 1080 - 1085