Assessment of anterior scleral thickness in Turkish open angle glaucoma patients: an anterior segment optical coherence tomography study

被引:0
|
作者
Torun, Isil Merve [1 ]
Saridogan, Melike [1 ]
机构
[1] Med Hlth Sci Univ, Sultan Abdulhamid Han Training & Res Hosp, Dept Ophthalmol, Selimiye Town Tibbiye St, TR-34660 Istanbul, Turkiye
关键词
Anterior scleral thickness; Anterior segment optical coherence tomography; Primary open-angle glaucoma; Pseudoexfoliation glaucoma; Schlemm's canal; CORNEAL;
D O I
10.1186/s12886-025-03921-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To compare anterior scleral thickness (AST) in Turkish patients with open-angle glaucoma (primary open-angle glaucoma (POAG) and pseudoexfoliation glaucoma (PEG)) with healthy controls. Methods This prospective study involved 41 patients with PEG, 69 patients with POAG, and 46 healthy controls. We obtained spectral domain anterior segment optical coherence tomography (AS-OCT) images from the nasal and temporal quadrants and made AST measurements of 1 mm (AST), 2 mm (AST2), 3 mm (AST3), and 4 mm (AST4) posterior to the scleral spur (SS). Schlemm's canal (SC) diameter and area measurements were performed using the ImageJ software. The results were compared statistically. Results The average ASTs of the groups did not differ significantly (p > 0.05 for each). The analysis of the nasal SC diameter revealed a significant decrease in the POAG group in comparison with the PEG group, with no difference observed between the POAG and control groups (p = 0.038*). The mean nasal and temporal SC area was significantly smaller in the PEG and POAG groups compared with the control group (p < 0.001** and p < 0.001**, respectively). Conclusions There was no significant difference in nasal and temporal AST between groups; however, the SC area was found to be smaller in glaucoma groups compared with healthy controls. The present findings should be supported by further studies.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Assessment of the anterior segment of patients with primary congenital glaucoma using handheld optical coherence tomography
    Pilat, Anastasia, V
    Proudlock, Frank A.
    Shah, Sonal
    Sheth, Viral
    Purohi, Ravi
    Abbot, Joseph
    Gottlob, Irene
    EYE, 2019, 33 (08) : 1232 - 1239
  • [32] Evaluation of the Narrow Anterior Chamber Angle by Anterior Segment Optical Coherence Tomography
    Lan, Jie
    Sun, Dapeng
    Alabdulrasool, Khatoon
    Yusuf, Hassan Ebrahim
    Zhang, Lu
    OPHTHALMIC RESEARCH, 2017, 57 (02) : 87 - 91
  • [33] Reproducibility of Anterior Chamber Angle Measurements with Anterior Segment Optical Coherence Tomography
    Tan, Annelie N.
    Sauren, Loes D. C.
    de Brabander, John
    Berendschot, Tos T. J. M.
    Passos, Valeria Lima
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    Beckers, Henny J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) : 2095 - 2099
  • [34] Role of anterior segment optical coherence tomography in scleral diseases: A review
    Peraka, Raghav Preetam
    Murthy, Somasheila, I
    SEMINARS IN OPHTHALMOLOGY, 2023, 38 (03) : 238 - 247
  • [35] New developments in anterior segment optical coherence tomography for glaucoma
    Wang, Dajiang
    Lin, Shan
    CURRENT OPINION IN OPHTHALMOLOGY, 2016, 27 (02) : 111 - 117
  • [36] Anterior Scleral Thickness and Anterior Segment Biometrics Measured with Swept Source Ocular Coherence Tomography in High Myopic Eyes with and without Glaucoma: A Comparative Study
    Kudsieh, Bachar
    Vega-Gonzalez, Rocio
    Bryan, Sofia
    Almazan-Alonso, Elena
    Puertas, Mariluz
    Gutierrez-Martin, Lucia
    Flores-Moreno, Ignacio
    Ruiz-Medrano, Jorge
    Samaan, Muhsen
    Ruiz-Moreno, Jose Maria
    DIAGNOSTICS, 2024, 14 (06)
  • [37] Insights into scleral violaceous hue in anterior scleritis: anterior segment optical coherence tomography evaluation
    Sutra, Plern
    Pothikamjorn, Thananop
    Lopez, Sarah
    Takhar, Jaskirat
    Chongchareon, Mathinee
    Keenan, Jeremy
    Gonzales, John A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2025,
  • [38] Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment
    Dada, Tanuj
    Sihota, Ramanjit
    Gadia, Ritu
    Aggarwal, Anand
    Mandal, Subrata
    Gupta, Viney
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05): : 837 - 840
  • [39] Evaluation of the Effect of Scleral Buckling on Anterior Segment and Refractive Changes Using Anterior Segment Optical Coherence Tomography
    Wang, Minli
    Zhu, Juming
    Keyal, Khusbu
    Liao, Xin
    Chen, Lei
    Li, Hui
    Wang, Fang
    SEMINARS IN OPHTHALMOLOGY, 2024, 39 (01) : 74 - 82
  • [40] Characterizing Angle Landmarks with Anterior Segment Optical Coherence Tomography
    Crowell, Eric L.
    Gold, Mark E.
    Chuang, Alice
    Baker, Laura
    Feldman, Robert M.
    Bell, Nicholas P.
    Blieden, Lauren S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)