Self-Powered Neutron Detector with Hafnium Metal Emitter in VVER Reactors

被引:0
|
作者
Kalinushkin, A. E. [1 ]
Kurchenkov, A. Yu. [1 ]
Markov, D. S. [1 ]
Sergeev, I. A. [1 ]
机构
[1] Kurchatov Inst, Natl Res Ctr, Moscow 123182, Russia
关键词
self-powered neutron detector (SPND); hafnium metal emitter; in-core instrument system (ICIS); neutron flux monitoring system (NFMS);
D O I
10.1134/S1063778824080052
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
A self-powered neutron detector (SPND) with a neutron-sensitive emitter made of metallic hafnium is investigated. The SPND was manufactured at the National Research Center "Kurchatov Institute" and irradiated at the IR-8 reactor together with rhodium SPNDs. It is shown that, in contrast to the common SPND with a hafnium oxide emitter, this SPND produces an inertia-free signal that is only an order of magnitude smaller than that of the rhodium SPND.
引用
收藏
页码:1064 / 1066
页数:3
相关论文
共 50 条
  • [42] Study on structural and material dependence of Rhodium Self-powered Neutron Detector performance
    Wan, Bo
    Li, Gang
    Li, Kun
    Li, Dan
    Huang, Qichang
    Xia, Yuan
    Wei, Wenbin
    Luo, Ying
    Wang, Miao
    Yang, Daibo
    JOURNAL OF INSTRUMENTATION, 2024, 19 (05):
  • [43] DIGITAL INVERSE RESPONSE FUNCTION ANALYSIS OF SELF-POWERED NEUTRON DETECTOR SIGNALS
    CARPENTER, JM
    FLEMING, RF
    BOZORGMANESH, H
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1975, 22 (NOV16): : 606 - 607
  • [44] A Monte Carlo method for quantitatively calculating the neutron sensitivity of rhodium self-powered neutron detectors in reactors
    Wu, Xiong
    Jiang, Jieqiong
    Wu, Tingyu
    Luo, Shijie
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2024, 8 (02) : 1162 - 1170
  • [45] CALIBRATION OF SELF-POWERED NEUTRON DETECTORS
    SULCOSKI, MF
    WARREN, HD
    NUCLEAR SCIENCE AND ENGINEERING, 1983, 85 (03) : 245 - 250
  • [46] Selective and prompt self-powered neutron detectors for characterization of mixed radiation fields in reactors
    Blandin, C
    Breaud, S
    REACTOR DOSIMETRY: RADIATION METROLOGY AND ASSESSMENT, 2001, 1398 : 675 - 682
  • [47] Self-powered asymmetric metal-semiconductor-metal AIN deep ultraviolet detector
    Li, Tao
    Song, Wenqing
    Zhang, Lei
    Yan, Jianchang
    Zhu, Wenhui
    Wang, Liancheng
    OPTICS LETTERS, 2022, 47 (03) : 637 - 640
  • [48] DETERMINATION OF NEUTRON-FLUX AND NEUTRON FLUENCE FROM SIGNAL CURRENT OF A SELF-POWERED RHODIUM DETECTOR
    HUDRITSCH, WW
    NUCLEAR TECHNOLOGY, 1973, 18 (01) : 25 - 28
  • [49] Deconvolution-based real-time neutron flux reconstruction for Self-Powered Neutron Detector
    Zhang, Qingmin
    Deng, Bangjie
    Liu, Xinxin
    Li, Chengyuan
    Sang, Yaodong
    Cao, Liangzhi
    Bi, Guangwen
    Tang, Chuntao
    Zhang, Peng
    Tong, Dayin
    Li, Yang
    NUCLEAR ENGINEERING AND DESIGN, 2018, 326 : 261 - 267
  • [50] Radiation hardness of self-powered Si/SiC heterojunction detector under neutron irradiation
    Feng, Z. L.
    Gao, R. L.
    Liu, L. Y.
    Ma, W. Y.
    Jia, R.
    Xiaoping, O. Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1063