Self-Powered Neutron Detector with Hafnium Metal Emitter in VVER Reactors

被引:0
|
作者
Kalinushkin, A. E. [1 ]
Kurchenkov, A. Yu. [1 ]
Markov, D. S. [1 ]
Sergeev, I. A. [1 ]
机构
[1] Kurchatov Inst, Natl Res Ctr, Moscow 123182, Russia
关键词
self-powered neutron detector (SPND); hafnium metal emitter; in-core instrument system (ICIS); neutron flux monitoring system (NFMS);
D O I
10.1134/S1063778824080052
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
A self-powered neutron detector (SPND) with a neutron-sensitive emitter made of metallic hafnium is investigated. The SPND was manufactured at the National Research Center "Kurchatov Institute" and irradiated at the IR-8 reactor together with rhodium SPNDs. It is shown that, in contrast to the common SPND with a hafnium oxide emitter, this SPND produces an inertia-free signal that is only an order of magnitude smaller than that of the rhodium SPND.
引用
收藏
页码:1064 / 1066
页数:3
相关论文
共 50 条
  • [31] SOME THEORETICAL INVESTIGATIONS ON PROMPT SELF-POWERED NEUTRON DETECTORS - (HAFNIUM AND ERBIUM EMITTERS)
    ANTONOV, NA
    YORDANOV, YD
    NUCLEAR SCIENCE AND ENGINEERING, 1986, 94 (02) : 206 - 212
  • [32] Development of a self-powered gamma detector
    Takeuchi, Tomoaki
    Ohtsuka, Noriaki
    Shibata, Akira
    Tsuchiya, Kunihiko
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2014, 51 (7-8) : 939 - 943
  • [33] Development of bismuth self-powered detector
    Alex, M
    Prasad, KR
    Kataria, SK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 523 (1-2): : 163 - 166
  • [34] THE DETERMINATION OF SELF-POWERED NEUTRON DETECTOR SENSITIVITY ON THERMAL AND EPITHERMAL NEUTRON-FLUX DENSITIES
    ERBEN, O
    JADERNA ENERGIE, 1980, 26 (02): : 47 - 52
  • [35] The signal compensation method for the neutron flux in the measurement system using self-powered neutron detector
    Park, Heejune
    Noh, Myounggyu D.
    Park, Young-Woo
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (06):
  • [37] A Simple Iterative Method for Compensating the Response Delay of a Self-Powered Neutron Detector
    Zhang, Qingmin
    Hu, Zhigang
    Deng, Bangjie
    Xu, Mengxuan
    Guo, Yuhang
    NUCLEAR SCIENCE AND ENGINEERING, 2017, 186 (03) : 293 - 302
  • [38] Anomaly Detection of Core Self-Powered Neutron Detector Based on Twin Model
    Chen J.
    Lu Y.
    Jiang H.
    Lin W.
    Xu Y.
    Hedongli Gongcheng/Nuclear Power Engineering, 2023, 44 (03): : 210 - 216
  • [39] ACTIVATION COMPONENT OF THE RESPONSE OF A SELF-POWERED NEUTRON DETECTOR TO THERMAL AND EPITHERMAL NEUTRONS
    ERBEN, O
    SOVIET ATOMIC ENERGY, 1979, 46 (05): : 402 - 406
  • [40] Autoregressive moving average inverse dynamics for rhodium self-powered neutron detector
    Mayo, CW
    Yan, L
    NUCLEAR SCIENCE AND ENGINEERING, 1996, 124 (02) : 361 - 363