Endoscopic Stenting of a Fully Covered Self-Expandable Metal Stent with a Hole in Each Cavity in Malignant Hilar Biliary Obstruction: A Preclinical Proof-of-Concept Study and Initial Human Experience

被引:0
|
作者
Lee, Jungnam [1 ]
Jeong, Seok [1 ]
Lee, Don Haeng [1 ,2 ]
Lim, Jung-Hyun [1 ]
Kobayashi, Makoto [3 ]
Takenaka, Mamoru [4 ]
Kwon, Chang-, II [5 ]
机构
[1] Inha Univ, Coll Med, Dept Internal Med, Div Gastroenterol, Inchon, South Korea
[2] Utah Inha DDS & Adv Therapeut Res Ctr, Incheon 22212, South Korea
[3] Yokkaichi Municipal Hosp, Dept Neurosurg, Yokaichi, Japan
[4] Kindai Univ Fac Med, Dept Gastroenterol & Hepatol, Osaka, Japan
[5] CHA Univ, Digest Dis Ctr, CHA Bundang Med Ctr, Sch Med, Seongnam, South Korea
关键词
Fully covered self-expandable metal stent; Hilar cholangiocarcinoma; Malignant hilar biliary obstruction; Radio-frequency ablation; STRICTURES; CHOLANGIOCARCINOMA; FEASIBILITY;
D O I
10.1007/s10620-024-08810-1
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and AimStent placement for biliary drainage in patients with malignant hilar biliary obstruction (MHBO) has been a topic of long-standing debate, and the best approach remains controversial. Therefore, we aimed to evaluate the efficacy, safety, and removability of multi-hole fully covered self-expandable metal stents (MH-FCSEMSs) in a preclinical experiment using swine hilar bile duct obstruction (HBDO) models and to assess the feasibility and safety of stent placement in patients with MHBO.MethodsThree minipigs underwent endoscopic retrograde cholangiopancreatography (ERCP)-guided endobiliary-radio frequency ablation (EB-RFA) to establish Bismuth type II hilar bile duct stenosis models. Four weeks after EB-RFA, 10-mm diameter and 4-cm length MH-FCSEMSs were endoscopically inserted into the left intrahepatic bile duct of the models. Stent patency and migration, as well as adverse events including cholangitis and endoscopic stent removability, were assessed three months after stent placement. Additionally, clinical applications of MH-FCSEMS were performed in two patients with MHBO to determine feasibility, safety, and stent patency.ResultsMH-FCSEMSs were successfully inserted into the left main intrahepatic bile duct and common hepatic duct of the models under ERCP in all three animals without any technical difficulties. Cholangiograms performed 12 weeks after MH-FCSEMS placement showed no stent migration, and all were successfully removed from the animal models. The functional success rate, defined as a decrease in serum total bilirubin level of more than 50% at 12 weeks after stent placement, was 100%. Moreover, MH-FCSEMSs were successfully inserted in two patients with hilar cholangiocarcinoma. The procedures were technically feasible, and no major periprocedural complications were noted.ConclusionThe preliminary long-term results of both preclinical and clinical pilot studies suggest that endoscopic biliary drainage using MH-FCSEMS may be a safe and effective treatment option for stenting and stent revision in the management of HBDO. Further studies comparing clinical outcomes to those of MH-FCSEMS without multi-hole in malignant hilar biliary obstruction will be needed to verify the clinical benefits.
引用
收藏
页码:1215 / 1222
页数:8
相关论文
共 33 条
  • [31] Feasibility, effectiveness, and safety of simultaneous side-by-side deployment of uncovered self-expandable metal stents for malignant hilar biliary obstruction: a retrospective single-center study
    Chengcheng Christine Zhang
    Marcus Kantowski
    Cyrill Wehling
    Patrick Michl
    Ronald Koschny
    Peter Sauer
    BMC Gastroenterology, 25 (1)
  • [32] Intraductal placement of a fully covered metal stent with a long string for distal malignant biliary obstruction without endoscopic sphincterotomy: Prospective multi-center feasibility study
    Inoue, Tadahisa
    Suzuki, Yuta
    Okumura, Fumihiro
    Naitoh, Itaru
    Sano, Hitoshi
    Ibusuki, Mayu
    Kitano, Rena
    Kobayashi, Yuji
    Ito, Kiyoaki
    Yoneda, Masashi
    DIGESTIVE ENDOSCOPY, 2020, 32 (06) : 949 - 956
  • [33] Efficacy and Long-Term Outcomes of Side-by-Side Self-Expandable Metal Stent Placement Using a 2-Channel Endoscope for Unresectable Malignant Hilar Biliary Obstruction Occurring After Billroth II Reconstruction (with Video)
    Kosuke Okuwaki
    Hiroshi Yamauchi
    Mitsuhiro Kida
    Hiroshi Imaizumi
    Tomohisa Iwai
    Takaaki Matsumoto
    Yusuke Kawaguchi
    Kazuho Uehara
    Seigo Nakatani
    Wasaburo Koizumi
    Digestive Diseases and Sciences, 2018, 63 : 1641 - 1646