Optimization design method of soft x-ray multi-element optical system with two-dimension field light source for large aperture imaging

被引:0
|
作者
Cao, Yiqing [1 ,2 ]
Lu, Lijun [3 ]
Shen, Zhijuan [1 ]
机构
[1] Putian Univ, Sch Mech Elect & Informat Engn, Putian 351100, Fujian, Peoples R China
[2] Fujian Laser Precis Machining Engn Technol Res Ctr, Putian 351100, Fujian, Peoples R China
[3] Shanghai Univ, Sch Mechatron Engn & Automat, Shanghai 200072, Peoples R China
来源
EUROPEAN PHYSICAL JOURNAL PLUS | 2025年 / 140卷 / 01期
关键词
D O I
10.1140/epjp/s13360-024-05948-9
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Soft x-ray multi-element optical system with two-dimension field light source is widely used for synchrotron radiation, microscope, etc., and optimization design method of this kind of optical systems with large aperture imaging is studied in this paper. Since aberration analysis method is the basis for studying it, and thus, we firstly derived fifth-order aberration expressions of soft x-ray multi-element optical system with two-dimension field light source; secondly, the aberration modification expressions due to aperture-ray coordinates with second-order accuracy are obtained, and the extrinsic aberration calculation expressions are derived by the reverse optical path; then, aberration expressions derived in the above are validated and have a satisfactory calculation accuracy. In addition, evaluation function expression of imaging performance of this kind of optical systems is established, and then applying self-adaptive variation probability genetic optimization algorithm to solve it to obtain the structure parameters of optical system. Finally, they are applied to optimize the aberration of a soft x-ray multi-element optical system with two-dimension field light source, and comparing and analyzing the imaging results before and after aberration optimization; these results verify the effectiveness of the optimization method discussed in this paper.
引用
收藏
页数:13
相关论文
共 22 条
  • [1] Fifth-order intrinsic aberration and extrinsic aberration of soft x-ray multi-element orthogonal arrangement optical system with large aperture
    Cao, Yiqing
    Yao, Yonger
    Shen, Zhijuan
    Lu, Lijun
    JOURNAL OF OPTICS-INDIA, 2024,
  • [2] Extension of a fifth-order intrinsic aberration for a soft x-ray and vacuum ultraviolet optical system from a one- to two-dimension field light source
    Cao, YiQing
    Shen, ZhiJuan
    OPTICS EXPRESS, 2022, 30 (17) : 30260 - 30270
  • [3] Multi-element X-ray movie imaging with a visible-light CMOS camera
    Zhao, Wenyang
    Sakurai, Kenji
    JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 (01) : 230 - 233
  • [4] Design and characterization of the I-ImaS multi-element x-ray detector system
    Griffiths, Jennifer A.
    Metaxas, Marinos G.
    Royle, Gary J.
    Venanzi, Cristian
    Esbrand, Colin
    Cavouras, Dionisis
    Fant, Andrea
    Gasiorek, Przemyslaw
    Georgiou, Harris
    Hall, Geoff
    Jones, John
    Leaver, James D. G.
    Longo, Renata
    Manthos, Nicos
    Noy, Matthew
    Ostby, Joar Martin
    Rokvic, Tatjana
    Schulerud, Helene
    Theodoridis, Sergios
    Triantis, Frixos A.
    Turchetta, Renato
    Speller, Robert D.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 827 - 832
  • [5] Study on optimization design of X-ray source pinhole imaging system
    Xie, W.-Z., 1600, Atomic Energy Press (47):
  • [6] Fifth-order aberration for soft x-ray and vacuum ultraviolet multi-element optical systems
    Cao, Yiqing
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2022, 39 (01) : 143 - 151
  • [7] Towards a multi-element silicon drift detector system for fluorescence spectroscopy in the soft X-ray regime
    Bufon, Jernej
    Gianoncelli, Alessandra
    Ahangarianabhari, Mahdi
    Altissimo, Matteo
    Bellutti, Pierluigi
    Bertuccio, Giuseppe
    Borghes, Roberto
    Carrato, Sergio
    Cautero, Giuseppe
    Cicuttin, Andres
    Crespo, Maria Liz
    Fabiani, Sergio
    Gandola, Massimo
    Giacomini, Gabriele
    Giuressi, Dario
    Kourousias, George
    Menk, Ralf Hendrik
    Picciotto, Antonino
    Piemonte, Claudio
    Rachevski, Alexandre
    Rashevskaya, Irina
    Schillani, Stefano
    Stolfa, Andrea
    Vacchi, Andrea
    Zampa, Gianluigi
    Zampa, Nicola
    Zorzi, Nicola
    X-RAY SPECTROMETRY, 2017, 46 (05) : 313 - 318
  • [8] The choice method of light source radius in x-ray phase contrast imaging system
    Wu, Jie
    JOURNAL OF OPTICAL TECHNOLOGY, 2013, 80 (09) : 549 - 553
  • [9] DESIGN AND DEVELOPMENT OF SOFT-X-RAY IMAGING-SYSTEM AT TAIWAN LIGHT-SOURCE
    JAN, GJ
    HSU, KT
    PAN, KT
    CHEN, CS
    TSENG, PK
    ZOOLOGICAL STUDIES, 1995, 34 : 197 - 198
  • [10] X-ray absorption spectroscopy of diluted system by undulator photon source and multi-element solid-state detector
    Tanida, H
    Ishii, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 (PART II): : 1564 - 1567