Respiratory compliance related to prognostic of lung transplant patients with veno-venous extracorporeal membrane oxygenation support

被引:0
|
作者
Xuan, Chenhao [1 ]
Gu, Jingxiao [1 ]
Chen, Jingyu [2 ]
Xu, Hongyang [1 ]
机构
[1] Nanjing Med Univ, Affiliated Wuxi Peoples Hosp, Wuxi Med Ctr, Wuxi 214023, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Wuxi Lung Transplant Ctr, Affiliated Wuxi Peoples Hosp, Wuxi 214023, Jiangsu, Peoples R China
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Respiratory compliance; Extracorporeal membrane oxygenation; Lung transplant; Prognostic: intensive care unit; INTERNATIONAL SOCIETY; LIFE-SUPPORT; BRIDGE; EXPERIENCE; HEART;
D O I
10.1038/s41598-025-93396-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Veno-venous extracorporeal membrane oxygenation (VV-ECMO) plays an important role in the perioperative care of critically ill lung transplant patients. However, the factors predicting prognosis are unclear. This study assessed the association between static respiratory compliance (Crs) and outcomes of lung transplant patients receiving VV-ECMO in terms of 90-day mortality. Data were retrospectively collected for patients that underwent lung transplantation with VV-ECMO support during 2022-2023. Patients were divided into two groups according to the early postoperative Crs: lower Crs (Crs < 25 ml/cmH(2)O) and higher Crs (Crs >= 25 ml/cmH(2)O). Differences in patient characteristics and prognosis were then compared between the two groups. Receiver operating characteristic (ROC) curve analysis was used to evaluate the value of Crs for predicting 90-day mortality and univariate Cox proportional hazard model analysis was performed to estimate risk of Crs. Data were available for a total of 85 patients, including 50 (58.8%) patients in the higher Crs group and 35 (41.2%) patients in the lower Crs group. A lower Crs was significantly associated with a longer postoperative ECMO duration (hours, 42 vs. 24; P = 0.022), longer postoperative ventilator time (days, 3.7 vs. 2.0; P = 0.003), higher application of continuous renal replacement therapy (CRRT) (20.0% vs. 6.0%; P = 0.049), higher incidence of pneumonia (42.9% vs. 20.0%; P = 0.023), and higher 90-day mortality (22.9% vs. 6.0%; P = 0.023). The area under the curve of Crs for predicting 90-day mortality was 0.661 (P = 0.034). A higher Crs was a protective factor (hazard ratio = 0.925 [0.870-0.984)] P = 0.014). For lung transplant patients receiving VV-ECMO support, Crs < 25 ml/cmH(2)O is associated with more complications and higher 90-day mortality. As Crs is easily obtained at the bedside, it may be useful for predicting prognosis and guiding patient management.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Veno-venous extracorporeal membrane oxygenation in the management of refractory bilateral bronchial dehiscence after lung transplant: a case report
    Tani, Makiko
    JA CLINICAL REPORTS, 2021, 7 (01)
  • [32] The intricate physiology of veno-venous extracorporeal membrane oxygenation: an overview for clinicians
    Tomarchio, Emilia
    Momigliano, Francesca
    Giosa, Lorenzo
    Collins, Patrick Duncan
    Barrett, Nicholas A.
    Camporota, Luigi
    PERFUSION-UK, 2024, 39 (1_SUPPL): : 49S - 65S
  • [33] A case of veno-venous extracorporeal membrane oxygenation for severe respiratory failure in a superobese patient
    Belliato, Mirko
    Cremascoli, Luca
    Aliberti, Anna
    Pagani, Michele
    Pellegrini, Carlo
    Iotti, Giorgio Antonio
    CLINICAL CASE REPORTS, 2016, 4 (12): : 1147 - 1150
  • [34] Sedation Practice in Veno-Venous Extracorporeal Membrane Oxygenation: An International Survey
    Buscher, Hergen
    Vaidiyanathan, Saba
    Al-Soufi, Suhel
    Dinh Nguyen Nguyen
    Breeding, Jeff
    Rycus, Peter
    Nair, Priya
    ASAIO JOURNAL, 2013, 59 (06) : 636 - 641
  • [35] Veno-Venous Extracorporeal Membrane Oxygenation for Respiratory Failure: How Long Is Too Long?
    Menaker, Jay
    Rabinowitz, Ronald P.
    Tabatabai, Ali
    Tesoriero, Ronald B.
    Dolly, Katelyn
    Cornachione, Christopher
    Stene, Edward
    Buchner, Jessica
    Kufera, Joseph
    Kon, Zachary N.
    Deatrick, Kristopher B.
    Herr, Daniel L.
    O'Connor, James V.
    Scalea, Thomas M.
    ASAIO JOURNAL, 2019, 65 (02) : 192 - 196
  • [36] Awake veno-venous extracorporeal membrane oxygenation: practical aspects and considerations
    Paternoster, Gianluca
    Bertini, Pietro
    Sangalli, Fabio
    Scolletta, Sabino
    MINERVA ANESTESIOLOGICA, 2024, : 92 - 100
  • [37] State of the art: Monitoring of the respiratory system during veno-venous extracorporeal membrane oxygenation
    Collins, Patrick Duncan
    Giosa, Lorenzo
    Camporota, Luigi
    Barrett, Nicholas A.
    PERFUSION-UK, 2024, 39 (01): : 7 - 30
  • [38] eComment. Ambulatory veno-venous extracorporeal membrane oxygenation
    Hajj-Chahine, Jamil
    Jayle, Christophe
    Menu, Paul
    Corbi, Pierre
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 16 (01) : 59 - 59
  • [39] Veno-venous Extracorporeal Membrane Oxygenation Support in COVID-19 Respiratory Distress Syndrome: Initial Experience
    Loforte, Antonio
    Dal Checco, Erika
    Gliozzi, Gregorio
    Benedetto, Maria
    Cavalli, Giulio Giovanni
    Mariani, Carlo
    Piccone, Giulia
    Agulli, Marta
    Pacini, Davide
    Baiocchi, Massimo
    ASAIO JOURNAL, 2020, 66 (07) : 734 - 738
  • [40] Spontaneous breathing during veno-venous extracorporeal membrane oxygenation
    Crotti, Stefania
    Bottino, Nicola
    Spinelli, Elena
    JOURNAL OF THORACIC DISEASE, 2018, 10 : S661 - S669