Measurement of Radon and Thoron Concentrations in Rock Samples from the Iraqi Kurdistan Region Using Track Etch Detectors

被引:1
|
作者
Qadr, H. M. [1 ]
机构
[1] Univ Raparin, Coll Sci, Dept Phys, Sulaymaniyah 46012, Ranya, Iraq
关键词
rock sample; solid-state nuclear track detectors; radon concentration; thoron concentration; INDOOR RADON; ALPHA-PARTICLES; STOPPING POWER; DWELLINGS; DOSIMETER; KERALA;
D O I
10.1134/S1066362224060195
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The radon and thoron concentrations in sixteen types of rock samples collected from different areas in Sulaymaniyah Governorate, Kurdistan Region of Iraq, were determined using the tube technique with CR-39 solid-state detector. The radon and thoron concentrations in rock samples varied from 189 to 91 and from 112 to 54 Bq m(-3), respectively. The average radon and thoron concentrations in the sampling areas were 132 and 78 Bq m(-3), respectively. The radon concentrations were below the suggested range of 200 to 600 Bq m(-3) as recommended by ICRP. In addition, parameters related to the potential radiological hazards were calculated for the rock samples. The mean values of the estimated equilibrium potential alpha energy concentrations and annual effective dose for inhaled radon and thoron in the rock samples were 21.47, 2.117 mWL, and 1.252, 0.549 mSv year(-1), respectively. These values were compared with international standards.
引用
收藏
页码:937 / 943
页数:7
相关论文
共 21 条
  • [1] Radiological risk estimation from indoor radon, thoron, and their progeny concentrations using nuclear track detectors
    Gogoi, Pranjal Protim
    Barooah, Debajyoti
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2022, 194 (12)
  • [2] Measurement of indoor radon and thoron in the dwellings of Faizabad city using plastic track detectors
    Verma, Deepak
    Khan, M. Shakir
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2013, 51 (04) : 219 - 222
  • [3] A Simultaneous Measurement Method of Radon and Thoron Concentrations by Using a Scintillation Cell
    Zhao, Gui-zhi
    He, Zheng-zhong
    Liu, Yan-li
    Xiao, Yong-jun
    Fu, Yan
    Xiao, De-tao
    INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND ENERGY ENGINEERING (ICESEE 2015), 2015, : 164 - 169
  • [4] A method for the simultaneous measurement of radon and thoron PAEC concentrations in air using a TLD monitor
    Chalupnik, Stanislaw
    Skubacz, Krystian
    JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (04) : 1236 - 1246
  • [5] Estimation of annual effective dose from indoor radon/thoron concentrations and measurement of radon concentrations in soil
    Mehra, Rohit
    Bala, Pankaj
    RADIATION PROTECTION DOSIMETRY, 2014, 158 (01) : 111 - 114
  • [6] Radiological Impact of Radon and Thoron Levels in Dwellings Measured using Solid State Nuclear Track Detectors
    Singh, Bhupender
    Kanta, Krishan
    Garg, Maneesha
    Singh, Ajit
    Sahoo, B. K.
    Sapra, B. K.
    ADVANCES IN BASIC SCIENCES (ICABS 2019), 2019, 2142
  • [7] MEASUREMENT OF INDOOR RADON, THORON AND THEIR PROGENY LEVELS IN DWELLINGS OF AMBALA DISTRICT, HARYANA, NORTHERN INDIA USING SOLID STATE NUCLEAR TRACK DETECTORS
    Mehta, Vimal
    Singh, S. P.
    Chauhan, R. P.
    Mudahar, G. S.
    ROMANIAN JOURNAL OF PHYSICS, 2014, 59 (7-8): : 834 - 845
  • [8] Measurement of radon and thoron concentration by using LR-115 type-II plastic track detectors in the environ of Brahmaputra Valley, Assam, India
    Deka, PC
    Sarkar, S
    Bhattacharjee, B
    Goswami, TD
    Sarma, BK
    Ramachandran, TV
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 431 - 434
  • [9] Measurement of Variation of Radon-Thoron and their Progeny Concentrations in Dwellings using Pin Hole Based Dosimeters
    Shikha, Deep
    Mehta, Vimal
    Chauhan, Rishi Pal
    Mudahar, Gurmel Singh
    AEROSOL AND AIR QUALITY RESEARCH, 2018, 18 (03) : 811 - 819
  • [10] Long-term measurements of unattached radon progeny concentrations using solid-state nuclear track detectors
    Yu, K. N.
    Nikezic, D.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (07) : 1104 - 1106