Effect of crystalline lens decentration and tilt on visual performance in eyes implanted with bifocal or extended depth of focus intraocular lenses

被引:0
作者
Zhang, Yu [1 ,2 ]
Zhang, Jiaqing [1 ]
Liang, Chen [1 ]
Xu, Yifan [1 ,2 ]
Wu, Jiaying [2 ]
Wu, Junming [2 ]
Zhang, Yifan [1 ,2 ]
Jin, Aixia [1 ,2 ]
Tan, Xuhua [1 ]
Luo, Lixia [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangdong Prov Key Lab Ophthalmol & Visual Sci, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ Med Sci, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Cataract; Intraocular lens; IOL; Presbyopia-correcting IOL; Decentration; Tilt; RETINAL IMAGE QUALITY; OPTICAL-QUALITY; CONTRAST SENSITIVITY; ABERRATION; PRECISION; VISION;
D O I
10.1186/s12886-025-03884-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo explore the potential of crystalline lens decentration and tilt as indicators for screening cataract patients for presbyopia-correcting intraocular lens (IOL) implantation. MethodsProspective observational study. Patients undergoing phacoemulsification with bifocal (Tecnis ZMB00) or extended depth-of-focus (EDOF) (Tecnis ZXR00) IOL implantation were consecutively enrolled. The decentration and tilt of the crystalline lens and the IOL were quantified through the utilization of swept-source optical coherence tomography (SS-OCT, Casia2). Postoperative visual acuity (VA), contrast sensitivity (CS), objective optical quality, and patient-reported outcomes were assessed at a 3-month follow-up. A LOWESS (LOcally WEighted Scatterplot Smoothing) curve was employed to analyze the changes in VA, CS, and objective optical quality relative to the decentration or tilt of crystalline lenses. A further comparison of visual outcomes was conducted based on the inflection points suggested by the curves. ResultsEighty-seven patients with ZMB00 IOL and 76 patients with ZXR00 IOL were included. Multiple 6-mm internal aberrations showed a nonlinear increase with greater crystalline lens decentration. The inflection points for the steep increase were observed to be 0.28 mm for the bifocal group and 0.35 mm for the EDOF group. Beyond these points, internal aberrations such as coma increased significantly (all P < 0.01). Patient satisfaction decreased (P < 0.01). Moreover, the bifocal group exhibited a decline in spectacle-independence from 98.67% to 83.33% (P = 0.049), along with a reduction in CS (P < 0.05). ConclusionsThe increased decentration of crystalline lenses compromises specific visual quality aspects in eyes implanted with ZMB00 and ZXR00 IOLs, with cut-off values of 0.28 mm and 0.35 mm, respectively.
引用
收藏
页数:11
相关论文
共 56 条
  • [1] Catquest-9SF questionnaire: validation of Malay and Chinese-language versions using Rasch analysis
    Adnan, Tassha Hilda
    Apandi, Mokhlisoh Mohamed
    Kamaruddin, Haireen
    Salowi, Mohamad Aziz
    Law, Kian Boon
    Haniff, Jamaiyah
    Goh, Pik Pin
    [J]. HEALTH AND QUALITY OF LIFE OUTCOMES, 2018, 16 : 5
  • [2] Clinical Retinal Image Quality of a Non-diffractive Wavefront-Shaping Extended Depth of Focus (Vivity) Intraocular Lens
    Al-Amri, Saad Abdulrahman J.
    Alio, Jorge L.
    Milan-Castillo, Roberto
    D'Oria, Francesco
    Martinez-Abad, Antonio
    Yebana, Pilar
    Subirana, Nuria
    Al-Harbi, Ziyad
    Plaza-Puche, Ana B.
    Alio del Barrio, Jorge L.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (02) : 103 - +
  • [3] Retinal image quality with multifocal, EDoF, and accommodative intraocular lenses as studied by pyramidal aberrometry
    Alio, Jorge L.
    D'Oria, Francesco
    Toto, Francesca
    Balgos, Joan
    Palazon, Antonio
    Versaci, Francesco
    Alio del Barrio, Jorge L.
    [J]. EYE AND VISION, 2021, 8 (01)
  • [4] Comparison of visual and optical quality of monofocal versus multifocal intraocular lenses
    Altemir-Gomez, Irene
    Millan, Maria S.
    Vega, Fidel
    Bartol-Puyal, Francisco
    Gimenez-Calvo, Galadriel
    Larrosa, Jose M.
    Polo, Vicente
    Pablo, Luis E.
    Garcia-Martin, Elena
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (02) : 299 - 306
  • [5] Ashena Zahra, 2020, Vision (Basel), V4, DOI 10.3390/vision4030041
  • [6] Precision of higher order aberration repeatability with NIDEK OPD-Scan retinoscopic aberrometry
    Barreto, Jackson, Jr.
    Netto, Marcelo V.
    Cigna, Alberto
    Bechara, Samir
    Kara-Jose, Newton
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (09) : S1037 - S1040
  • [7] Tilt and decentration of spherical and aspheric intraocular lenses: Effect on higher-order aberrations
    Baumeister, Martin
    Buehren, Jens
    Kohnen, Thomas
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (06) : 1006 - 1012
  • [8] Multifocal intraocular lenses: Relative indications and contraindications for implantation
    Braga-Mele, Rosa
    Chang, David
    Dewey, Steven
    Foster, Gary
    Henderson, Bonnie An
    Hill, Warren
    Hoffman, Richard
    Little, Brian
    Mamalis, Nick
    Oetting, Thomas
    Serafano, Donald
    Talley-Rostov, Audrey
    Vasavada, Abhay
    Yoo, Sonia
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (02) : 313 - 322
  • [9] OPTICAL QUALITY OF HUMAN EYE
    CAMPBELL, FW
    GUBISCH, RW
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1966, 186 (03): : 558 - +
  • [10] Intraocular lens optics and aberrations
    Chang, Daniel H.
    Rocha, Karolinne M.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2016, 27 (04) : 298 - 303