Development and Validation of a Gas Chromatography-Mass Spectrometry Method for the Determination of Fentanyl and Butyryl Fentanyl in Oral Fluid

被引:1
作者
Camedda, Nicola [1 ]
Dagoli, Sara [1 ]
Anzillotti, Luca [1 ]
Cecchi, Rossana [2 ]
机构
[1] Univ Parma, Dept Med & Surg, Legal Med, Parma, Italy
[2] Univ Modena & Reggio Emilia, Inst Legal Med, Dept Biochem Metab & Neural Sci, Modena, Italy
来源
ANALYTICAL SCIENCE ADVANCES | 2025年 / 6卷 / 01期
关键词
butyryl fentanyl; fentanyl; gas chromatography-mass spectrometry; oral fluid; synthetic opioids; GC-MS; URINE; ANALOGS; PLASMA; SALIVA; ABUSE; BLOOD;
D O I
10.1002/ansa.202400038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Synthetic opioids are lab-synthesized substances that target the brain's opioid receptors, offering analgesic and sedative effects. Amongst them, fentanyl is one of the most widely used to intervene in chronic pain in moderate to severe cancer situations. Butyryl fentanyl (BF) is a novel synthetic opioid whose use is growing. Its potency is seven times that of morphine and, unlike fentanyl, BF can only be obtained through illegal sources. Fentanyl and its analogues are related to harmful intoxications and an increase in opioid-related mortality in many countries, such as in the United States and Europe in recent years. This work developed and validated an effective and sensitive method based on solid-phase extraction followed by gas chromatography-mass spectrometry (GC-MS) for the determination of fentanyl and BF in oral fluid samples. To the best of our knowledge, it is the first successful attempt to quantify these analytes using GC-MS with a limit of quantification (LOQ) of 1 ng/mL in OF. Intra-day and inter-day percentage coefficient of variation were found within 1%-3% and 1%-14%, respectively, while accuracy ranged from 92% to 102% at four concentration levels (lower LOQ [LLOQ], 3, 20, 40 ng/mL) in accordance with the established criteria. The absolute recovery values were in the range of 80.0%-100.0%. The method was linear for all analytes, with quadratic regression of calibration curves always higher than 0.99. The validated method demonstrated its great potential to detect and quantify fentanyl and its analogue in OF and it can be useful not only in forensic investigations of addiction histories but also in epidemiological studies on the spread of fentanyl and BF among workers and/or drivers.
引用
收藏
页数:8
相关论文
共 48 条
[11]   The Opioid Crisis-Not Just Opioids Anymore [J].
Brent, Jeffrey ;
Weiss, Stephanie T. .
JAMA NETWORK OPEN, 2022, 5 (06)
[12]   Recent advances of drugs monitoring in oral fluid and comparison with blood [J].
Casati, Sara ;
Binda, Maddalena ;
Dongiovanni, Paola ;
Meroni, Marica ;
D'Amato, Alfonsina ;
Roda, Gabriella ;
Orioli, Marica ;
Del Fabbro, Massimo ;
Tartaglia, Gianluca M. M. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) :1978-1993
[13]  
Davis MP, 2011, EXPERT REV NEUROTHER, V11, P1197, DOI [10.1586/ERN.11.63, 10.1586/ern.11.63]
[14]   Alternative matrices in forensic toxicology: a critical review [J].
de Campos, Eduardo Geraldo ;
da Costa, Bruno Ruiz Brandao ;
dos Santos, Fabiana Spineti ;
Monedeiro, Fernanda ;
Alves, Marcela Nogueira Rabelo ;
Santos Junior, Wilson Jose Ramos ;
De Martinis, Bruno Spinosa .
FORENSIC TOXICOLOGY, 2022, 40 (01) :1-18
[15]  
Drug Enforcement Administration Department of Justice Schedules of Controlled Substances, PLACEMENT BUTYRYL FE
[16]   Saliva as an alternative specimen to plasma for drug bioanalysis: A review [J].
Elmongy, Hatem ;
Abdel-Rehim, Mohamed .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 83 :70-79
[17]  
European Medicines Agency, ICH GUIDELINE M10 BI
[18]   Analysis of Acetyl Fentanyl in Postmortem Specimens by Gas Chromatography-Mass Spectrometry (GC-MS): Method Validation and Case Report [J].
Finkelstein, Marissa J. ;
Chronister, Chris W. ;
Stanley, Christina ;
Ogilvie, Laurie M. ;
Goldberger, Bruce A. .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2019, 43 (05) :392-398
[19]   Analysis of Fentanyl and 18 Novel Fentanyl Analogs and Metabolites by LC-MS-MS, and report of Fatalities Associated with Methoxyacetylfentanyl and Cyclopropylfentanyl [J].
Fogarty, Melissa F. ;
Papsun, Donna M. ;
Logan, Barry K. .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2018, 42 (09) :592-604
[20]   Development and validation of quantitative analytical method for 50 drugs of antidepressants, benzodiazepines and opioids in oral fluid samples by liquid chromatography-tandem mass spectrometry [J].
Furiozo Arantes, Ana Carolina ;
da Cunha, Kelly Francisco ;
Cardoso, Marilia Santoro ;
Oliveira, Karina Diniz ;
Costa, Jose Luiz .
FORENSIC TOXICOLOGY, 2021, 39 (01) :179-197