Selection of density standard and X-ray tube settings for computed digital absorptiometry in horses using the k-means clustering algorithm

被引:1
作者
Turek, Bernard [1 ]
Pawlikowski, Marek [2 ]
Jankowski, Krzysztof [2 ]
Borowska, Marta [3 ]
Skierbiszewska, Katarzyna [1 ]
Jasinski, Tomasz [1 ]
Domino, Malgorzata [1 ]
机构
[1] Warsaw Univ Life Sci WULS SGGW, Inst Vet Med, Dept Large Anim Dis & Clin, Nowoursynowska 100, PL-02797 Warsaw, Poland
[2] Warsaw Univ Technol, Inst Mech & Printing, Narbutta 85, PL-02524 Warsaw, Poland
[3] Bialystok Tech Univ, Inst Biomed Engn, Fac Mech Engn, Wiejska 45C, PL-15351 Bialystok, Poland
关键词
Computed digital absorptiometry; Bone mineral density; Radiological signs; Distal limbs; Horse; BONE-MINERAL DENSITY; DUAL-ENERGY CT; RADIOGRAPHIC ABSORPTIOMETRY; 3RD METACARPUS; EQUINE BONE; TOMOGRAPHY; JOINT; FEATURES; SPINE;
D O I
10.1186/s12917-025-04591-5
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
BackgroundIn veterinary medicine, conventional radiography is the first-choice method for most diagnostic imaging applications in both small animal and equine practice. One direction in its development is the integration of bone density evaluation and artificial intelligence-assisted clinical decision-making, which is expected to enhance and streamline veterinarians' daily practices. One such decision-support method is k-means clustering, a machine learning and data mining technique that can be used clinically to classify radiographic signs into healthy or affected clusters. The study aims to investigate whether the k-means clustering algorithm can differentiate cortical and trabecular bone in both healthy and affected horse limbs. Therefore, identifying the optimal computed digital absorptiometry parameters was necessary.Methods and resultsFive metal-made density standards, made of pure aluminum, aluminum alloy (duralumin), cuprum alloy, iron-nickel alloy, and iron-silicon alloy, and ten X-ray tube settings were evaluated for the radiographic imaging of equine distal limbs, including six healthy limbs and six with radiographic signs of osteoarthritis. Density standards were imaged using ten combinations of X-ray tube settings, ranging from 50 to 90 kV and 1.2 to 4.0 mAs. The relative density in Hounsfield units was firstly returned for both bone types and density standards, then compared, and finally used for clustering. In both healthy and osteoarthritis-affected limbs, the relative density of the long pastern bone (the proximal phalanx) differed between bone types, allowing the k-means clustering algorithm to successful differentiate cortical and trabecular bone.ConclusionDensity standard made of duralumin, along with the 60 kV, 4.0 mAs X-ray tube settings, yielded the highest clustering metric values and was therefore considered optimal for further research. We believe that the identified optimal computed digital absorptiometry parameters may be recommended for further researches on the relative quantification of conventional radiographs and for distal limb examination in equine veterinary practice.
引用
收藏
页数:19
相关论文
共 78 条
[1]   Mass attenuation coefficients of X-rays in different barite concrete used in radiation protection as shielding against ionizing radiation [J].
Airton Almeida Junior, T. ;
Nogueira, M. S. ;
Vivolo, V. ;
Potiens, M. P. A. ;
Campos, L. L. .
RADIATION PHYSICS AND CHEMISTRY, 2017, 140 :349-354
[2]   Automatic Human Brain Tumor Detection in MRI Image Using Template-Based K Means and Improved Fuzzy C Means Clustering Algorithm [J].
Alam, Md Shahariar ;
Rahman, Md Mahbubur ;
Hossain, Mohammad Amazad ;
Islam, Md Khairul ;
Ahmed, Kazi Mowdud ;
Ahmed, Khandaker Takdir ;
Singh, Bikash Chandra ;
Miah, Md Sipon .
BIG DATA AND COGNITIVE COMPUTING, 2019, 3 (02) :1-18
[3]   Dual-Energy X-Ray Absorptiometry (DEXA) Scan Versus Computed Tomography for Bone Density Assessment [J].
Alawi, Malak ;
Begum, Azra ;
Harraz, Mohammed ;
Alawi, Hani ;
Bamagos, Shahd ;
Yaghmour, Abdulmalek ;
Hafiz, Lubna .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (02)
[4]   Influence of surgical intervention at the level of the dorsal spinous processes on the biomechanics of the equine thoracolumbar spine [J].
Baudisch, Natalie ;
Singer, Ellen ;
Jensen, Katharina Charlotte ;
Eichler, Fabienne ;
Meyer, Henning Juergen ;
Lischer, Christoph ;
Ehrle, Anna .
EQUINE VETERINARY JOURNAL, 2024, :492-501
[5]   Computed tomographic study analysing functional biomechanics in the thoracolumbar spine of horses with and without spinal pathology [J].
Baudisch, Natalie ;
Schneidewind, Lukas ;
Becke, Sophie ;
Keller, Max ;
Overhoff, Milena ;
Tettke, Dennis ;
Gruben, Viola ;
Eichler, Fabienne ;
Meyer, Henning Juergen ;
Lischer, Christoph ;
Ehrle, Anna .
ANATOMIA HISTOLOGIA EMBRYOLOGIA, 2024, 53 (01)
[6]   A novel fuzzy C-means algorithm for unsupervised heterogeneous tumor quantification in PET [J].
Belhassen, Saoussen ;
Zaidi, Habib .
MEDICAL PHYSICS, 2010, 37 (03) :1309-1324
[7]  
Bell RA, 2001, J ANIM SCI, V79, P1142
[8]   Recent Progress in Epicardial and Pericardial Adipose Tissue Segmentation and Quantification Based on Deep Learning: A Systematic Review [J].
Bencevic, Marin ;
Galic, Irena ;
Habijan, Marija ;
Pizurica, Aleksandra .
APPLIED SCIENCES-BASEL, 2022, 12 (10)
[9]   Selection of X-ray Tube Settings for Relative Bone Density Quantification in the Knee Joint of Cats Using Computed Digital Absorptiometry [J].
Bonecka, Joanna ;
Turek, Bernard ;
Jankowski, Krzysztof ;
Borowska, Marta ;
Jasinski, Tomasz ;
Skierbiszewska, Katarzyna ;
Domino, Malgorzata .
SENSORS, 2024, 24 (17)
[10]   Relationship between Feline Knee Joint Osteoarthritis and Bone Mineral Density Quantified Using Computed Tomography and Computed Digital Absorptiometry [J].
Bonecka, Joanna ;
Turek, Bernard ;
Jankowski, Krzysztof ;
Borowska, Marta ;
Jasinski, Tomasz ;
Smyth, Graham ;
Domino, Malgorzata .
ANIMALS, 2024, 14 (17)