On the Effect of the Patient Table on Attenuation in Myocardial Perfusion Imaging SPECT

被引:0
作者
Huxohl, Tamino [1 ]
Patel, Gopesh [1 ]
Burchert, Wolfgang [1 ]
机构
[1] Ruhr Univ Bochum, Bielefeld Univ, Univ Hosp,Heart & Diabet Ctr North Rhine Westphali, Inst Radiol Nucl Med & Mol Imaging,Med Fac OWL, Bad Oeynhausen, Germany
关键词
SPECT; Myocardial perfusion imaging (MPI); Attenuation correction; Patient table;
D O I
10.1186/s40658-024-00713-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe topic of the effect of the patient table on attenuation in myocardial perfusion imaging (MPI) SPECT is gaining new relevance due to deep learning methods. Existing studies on this effect are old, rare and only consider phantom measurements, not patient studies. This study investigates the effect of the patient table on attenuation based on the difference between reconstructions of phantom scans and polar maps of patient studies.MethodsJaszczak phantom scans are acquired according to quality control and MPI procedures. An algorithm is developed to automatically remove the patient table from the CT for attenuation correction. The scans are then reconstructed with attenuation correction either with or without the patient table in the CT. The reconstructions are compared qualitatively and on the basis of their percentage difference. In addition, a small retrospective cohort of 15 patients is examined by comparing the resulting polar maps. Polar maps are compared qualitatively and based on the segment perfusion scores.ResultsThe phantom reconstructions look qualitatively similar in both the quality control and MPI procedures. The percentage difference is highest in the lower part of the phantom, but it always remains below 17.5%. Polar maps from patient studies also look qualitatively similar. Furthermore, the segment scores are not significantly different (p=0.83).ConclusionsThe effect of the patient table on attenuation in MPI SPECT is negligible.
引用
收藏
页数:9
相关论文
共 20 条
[1]  
AakashD Shanbhag, 2022, Journal of Nuclear Medicine
[2]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[3]   Cross-vender, cross-tracer, and cross-protocol deep transfer learning for attenuation map generation of cardiac SPECT [J].
Chen, Xiongchao ;
Hendrik Pretorius, P. ;
Zhou, Bo ;
Liu, Hui ;
Johnson, Karen ;
Liu, Yi-Hwa ;
King, Michael A. ;
Liu, Chi .
JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (06) :3379-3391
[4]   Direct and indirect strategies of deep-learning-based attenuation correction for general purpose and dedicated cardiac SPECT [J].
Chen, Xiongchao ;
Zhou, Bo ;
Xie, Huidong ;
Shi, Luyao ;
Liu, Hui ;
Holler, Wolfgang ;
Lin, MingDe ;
Liu, Yi-Hwa ;
Miller, Edward J. ;
Sinusas, Albert J. ;
Liu, Chi .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (09) :3046-3060
[5]   CT-free attenuation correction for dedicated cardiac SPECT using a 3D dual squeeze-and-excitation residual dense network [J].
Chen, Xiongchao ;
Zhou, Bo ;
Shi, Luyao ;
Liu, Hui ;
Pang, Yulei ;
Wang, Rui ;
Miller, Edward J. ;
Sinusas, Albert J. ;
Liu, Chi .
JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (05) :2235-2250
[6]  
Fricke H, 2004, J NUCL MED, V45, P1619
[7]   Quantitation in gated perfusion SPECT imaging: The Cedars-Sinai approach [J].
Germano, Guido ;
Kavanagh, Paul B. ;
Slomka, Piotr J. ;
Van Kriekinge, Serge D. ;
Pollard, Geoff ;
Berman, Daniel S. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (04) :433-454
[8]   Attenuation correction in myocardial perfusion SPECT/CT: Effects of misregistration and value of reregistration [J].
Goetze, Sibyll ;
Brown, Tracy L. ;
Lavely, William C. ;
Zhang, Zhe ;
Bengel, Frank M. .
JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (07) :1090-1095
[9]   Clinical value of attenuation correction in stress-only Tc-99m sestamibi SPECT imaging [J].
Heller, GV ;
Bateman, TM ;
Johnson, LL ;
Cullom, SJ ;
Case, JA ;
Galt, JR ;
Garcia, EV ;
Haddock, K ;
Moutray, KL ;
Poston, C ;
Botvinick, EH ;
Fish, MB ;
Follansbee, WP ;
Hayes, S ;
Iskandrian, AE ;
Mahmarian, JJ ;
Vandecker, W .
JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (03) :273-281
[10]  