The Impact of Radiation Therapy on Intrathecal Drug Delivery System Functioning and Safety

被引:0
作者
Hao, David [1 ]
Lee, Donghwan [1 ]
Shah, Shivam S. [2 ]
Shekoohi, Sahar [3 ]
Kaye, Alan D. [3 ,4 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Anesthesia Crit Care & Pain Med, Boston, MA 02114 USA
[2] Louisiana State Univ, Sch Med, Hlth Sci Ctr Shreveport, Shreveport, LA 71103 USA
[3] Louisiana State Univ, Dept Anesthesiol, Hlth Sci Ctr Shreveport, Shreveport, LA 71103 USA
[4] Louisiana State Univ, Hlth Sci Ctr Shreveport, Dept Pharmacol Toxicol & Neurosci, Shreveport, LA 71103 USA
关键词
Intrathecal drug delivery system; Radiation therapy; Implantable medical devices; Pain management; Device malfunction; CHRONIC PAIN MANAGEMENT; PROTON THERAPY; CANCER; RADIOTHERAPY; PUMPS; LUNG;
D O I
10.1007/s11916-025-01375-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose of ReviewIntrathecal drug delivery systems (IDDS) are integral to managing chronic pain and spasticity, especially in oncology patients who may also require radiation therapy (RT). Concerns regarding the potential effects of ionizing radiation on IDDS functionality have been raised, with limited but growing evidence on device resilience. This review summarizes the current literature on radiation-induced IDDS malfunctions, identifies key risk factors, and discusses mitigation strategies.Recent FindingsAlthough most IDDS remain functional during RT, isolated cases of radiation-induced pump failure have been reported. Factors such as radiation dose, proximity to the treatment field, and shielding methods influence device susceptibility to failure. Case studies and retrospective reviews have suggested that cumulative doses above 10 Gy may increase malfunction risks, though some devices have withstood doses as high as 36 Gy without failure. Advances in RT, including proton therapy and stereotactic techniques, may reduce exposure to IDDS. Current recommendations emphasize preemptive planning, shielding strategies, and close post-radiation monitoring to mitigate these potential risks.SummaryRT presents unique challenges for patients with IDDS, requiring a multidisciplinary approach to balance cancer treatment efficacy with device integrity. While modern IDDS demonstrate resilience to radiation exposure, careful consideration of radiation dose thresholds, device placement, and shielding is needed. Given the lack of standardized guidelines, more research is needed to establish evidence-based protocols to optimize patient safety and device performance during RT.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Efficacy of intrathecal drug delivery system for refractory cancer pain patients: A single tertiary medical center experience
    Lin, Chih-Peng
    Lin, Wen-Ying
    Lin, Feng-Sheng
    Lee, Yow-Shan
    Jeng, Chuen-Shin
    Sun, Wei-Zen
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2012, 111 (05) : 253 - 257
  • [22] RGD-engineered nanoparticles as an innovative drug delivery system in cancer therapy
    Sanati, Mehdi
    Afshari, Amir R.
    Aminyavari, Samaneh
    Kesharwani, Prashant
    Jamialahmadi, Tannaz
    Sahebkar, Amirhossein
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2023, 84
  • [23] Removal of Intrathecal Catheters Used in Drug Delivery Systems
    Frizon, Leonardo A.
    Sabharwal, Navin C.
    Maiti, Tanmoy
    Golubovsky, Joshua
    May, Francis
    Shao, Jianning
    Machado, Andre G.
    Nagel, Sean J.
    NEUROMODULATION, 2018, 21 (07): : 665 - 668
  • [24] Attitudes of Hospice Providers Regarding Intrathecal Targeted Drug Delivery for Patients With Cancer
    Warner, Lindsay L.
    Moeschler, Susan S.
    Pittelkow, Thomas P.
    Strand, Jacob J.
    AMERICAN JOURNAL OF HOSPICE & PALLIATIVE MEDICINE, 2019, 36 (11) : 955 - 958
  • [25] Evaluation of usefulness of scintigraphic imaging in diagnosis of intrathecal drug delivery system malfunction - a preliminary report
    Teodorczyk, Jacek
    Szmuda, Tomasz
    Sieminski, Mariusz
    Lass, Piotr
    Sloniewski, Pawel
    POLISH JOURNAL OF RADIOLOGY, 2013, 78 (03) : 21 - 27
  • [26] Accuracy of Template Versus Ultrasound Identification of the Reservoir Access Port of Intrathecal Drug Delivery System
    Matthys, Camille
    Jacobs, Myriam
    Rossat, Julien
    Perruchoud, Christophe
    NEUROMODULATION, 2020, 23 (07): : 944 - 948
  • [27] Intrathecal Drug Delivery System: A Pain Management Option for Refractory Cancer-Related Pain
    Wanderman, Robalee L.
    Hagedorn, Jonathan M.
    PAIN MEDICINE, 2021, 22 (02) : 523 - 526
  • [28] Efficacy and Safety of Intrathecal Morphine for Cesarean Delivery: A Narrative Review
    Kaye, Alan D.
    Lindberg, Anne M.
    Shah, Shivam S.
    Maitski, Rebecca J.
    Pendarvis, Emily B.
    Cooley, Jada F.
    Amarasinghe, Sam
    Patel, Sagar
    Palowsky, Zachary
    Fox, Charles J.
    Ahmadzadeh, Shahab
    Shekoohi, Sahar
    Robinson, Christopher L.
    CURRENT PAIN AND HEADACHE REPORTS, 2024, 28 (10) : 1007 - 1013
  • [29] Leukoencephalopathy and Disseminated Necrotizing Leukoencephalopathy Following Intrathecal Methotrexate Chemotherapy and Radiation Therapy for Central Nerve System Lymphoma or Leukemia
    Kim, Ji Yeon
    Kim, Sung Tae
    Nam, Do-Hyun
    Lee, Jung-Il
    Park, Kwan
    Kong, Doo-Sik
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2011, 50 (04) : 304 - 310
  • [30] Optimizing the delivery of radiation therapy to cancer patients
    Shepard, DM