The Impact of Radiation Therapy on Intrathecal Drug Delivery System Functioning and Safety

被引:0
|
作者
Hao, David [1 ]
Lee, Donghwan [1 ]
Shah, Shivam S. [2 ]
Shekoohi, Sahar [3 ]
Kaye, Alan D. [3 ,4 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Anesthesia Crit Care & Pain Med, Boston, MA 02114 USA
[2] Louisiana State Univ, Sch Med, Hlth Sci Ctr Shreveport, Shreveport, LA 71103 USA
[3] Louisiana State Univ, Dept Anesthesiol, Hlth Sci Ctr Shreveport, Shreveport, LA 71103 USA
[4] Louisiana State Univ, Hlth Sci Ctr Shreveport, Dept Pharmacol Toxicol & Neurosci, Shreveport, LA 71103 USA
关键词
Intrathecal drug delivery system; Radiation therapy; Implantable medical devices; Pain management; Device malfunction; CHRONIC PAIN MANAGEMENT; PROTON THERAPY; CANCER; RADIOTHERAPY; PUMPS; LUNG;
D O I
10.1007/s11916-025-01375-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose of ReviewIntrathecal drug delivery systems (IDDS) are integral to managing chronic pain and spasticity, especially in oncology patients who may also require radiation therapy (RT). Concerns regarding the potential effects of ionizing radiation on IDDS functionality have been raised, with limited but growing evidence on device resilience. This review summarizes the current literature on radiation-induced IDDS malfunctions, identifies key risk factors, and discusses mitigation strategies.Recent FindingsAlthough most IDDS remain functional during RT, isolated cases of radiation-induced pump failure have been reported. Factors such as radiation dose, proximity to the treatment field, and shielding methods influence device susceptibility to failure. Case studies and retrospective reviews have suggested that cumulative doses above 10 Gy may increase malfunction risks, though some devices have withstood doses as high as 36 Gy without failure. Advances in RT, including proton therapy and stereotactic techniques, may reduce exposure to IDDS. Current recommendations emphasize preemptive planning, shielding strategies, and close post-radiation monitoring to mitigate these potential risks.SummaryRT presents unique challenges for patients with IDDS, requiring a multidisciplinary approach to balance cancer treatment efficacy with device integrity. While modern IDDS demonstrate resilience to radiation exposure, careful consideration of radiation dose thresholds, device placement, and shielding is needed. Given the lack of standardized guidelines, more research is needed to establish evidence-based protocols to optimize patient safety and device performance during RT.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Medical Cost Impact of Intrathecal Drug Delivery for Noncancer Pain
    Guillemette, Scott
    Witzke, Susan
    Leier, Jacqueline
    Hinnenthal, Jennifer
    Prager, Joshua P.
    PAIN MEDICINE, 2013, 14 (04) : 504 - 515
  • [2] Implanted Intrathecal Drug Delivery Systems and Radiation Treatment
    Gebhardt, Rodolfo
    Ludwig, Michelle
    Kirsner, Steve
    Kisling, Kelly
    Kosturakis, Alyssa K.
    PAIN MEDICINE, 2013, 14 (03) : 398 - 402
  • [3] Loss of effectiveness with an implanted drug delivery system for intrathecal pain therapy due to corrosion
    Reining, Marco
    Kretzschmar, Michael
    PAIN PRACTICE, 2023, 23 (04) : 459 - 462
  • [4] Bleeding Complications in Patients Undergoing Intrathecal Drug Delivery System Implantation
    Warner, Nafisseh S.
    Bendel, Markus A.
    Warner, Matthew A.
    Strand, Jacob J.
    Gazelka, Halena M.
    Hoelzer, Bryan C.
    Mauck, William D.
    Lamer, Tim J.
    Kor, Daryl J.
    Moeschler, Susan M.
    PAIN MEDICINE, 2017, 18 (12) : 2422 - 2427
  • [5] Advances in intrathecal drug delivery
    Lawson, Erin F.
    Wallace, Mark S.
    CURRENT OPINION IN ANESTHESIOLOGY, 2012, 25 (05) : 572 - 576
  • [6] Advances in intrathecal drug delivery
    De Andres, Jose
    Asensio-Samper, Juan M.
    Fabregat-Cid, Gustavo
    CURRENT OPINION IN ANESTHESIOLOGY, 2013, 26 (05) : 594 - 599
  • [7] Modern Radiation Therapy Planning and Delivery
    Gardner, Stephen J.
    Kim, Joshua
    Chetty, Indrin J.
    HEMATOLOGY-ONCOLOGY CLINICS OF NORTH AMERICA, 2019, 33 (06) : 947 - +
  • [8] The Impact of Fatigue on Role Functioning During Radiation Therapy
    Poirier, Patricia
    ONCOLOGY NURSING FORUM, 2011, 38 (04) : 457 - 465
  • [9] An Intrathecally Located Broken Catheter Used for an Intrathecal Drug Delivery System
    Kim, Jae Hun
    Nahm, Francis Sangun
    Chang, Jee Eun
    Park, Soo Young
    Kim, Yong Chul
    Lee, Sang Chul
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2012, 27 (10) : 1278 - 1281
  • [10] Pontine Hemorrhage Following a Recently Implanted Intrathecal Drug Delivery System
    Rosenfeld, David M.
    Trentman, Terrence
    Patel, Naresh P.
    PAIN PRACTICE, 2009, 9 (04) : 312 - 316