Effects of 1800 MHz and 2100 MHz mobile phone radiation on the blood-brain barrier of New Zealand rabbits

被引:0
作者
Kizilcay, Abdullah Oguz [1 ]
Tutuncu, Bilal [2 ]
Kocarslan, Mehmet [3 ]
Gozel, Mahmut Ahmet [4 ]
机构
[1] Zonguldak Bulent Ecevit Univ, Dept Comp Engn, Zonguldak, Turkiye
[2] Istanbul Tech Univ, Energy Inst, Istanbul, Turkiye
[3] Van Yuzuncu Yil Univ, Dursun Odabas Med Fac, Dept Sterilizat, Van, Turkiye
[4] Suleyman Demirel Univ, Dept Elect & Elect Engn, Isparta, Turkiye
关键词
Electromagnetic radiation; GSM frequencies; Blood-brain barrier; New Zealand rabbit; RADIOFREQUENCY RADIATION; OXIDATIVE STRESS; EXPOSURE; PERMEABILITY;
D O I
10.1007/s11517-024-03238-1
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this study, the impact of mobile phone radiation on blood-brain barrier (BBB) permeability was investigated. A total of 21 New Zealand rabbits were used for the experiments, divided into three groups, each consisting of 7 rabbits. One group served as the control, while the other two were exposed to electromagnetic radiation at frequencies of 1800 MHz with a distance of 14.5 cm and 2100 MHz with a distance of 17 cm, maintaining a constant power intensity of 15 dBm, for a duration equivalent to the current average daily conversation time of 38 min. The exposure was conducted under non-thermal conditions, with RF radiation levels approximately ten times lower than normal values. Evans blue (EB) dye was used as a marker to assess BBB permeability. EB binds to plasma proteins, and its presence in brain tissue indicates a disruption in BBB integrity, allowing for a quantitative evaluation of radiation-induced permeability changes. Left and right brain tissue samples were analyzed using trichloroacetic acid (TCA) and phosphate-buffered solution (PBS) solutions to measure EB amounts at 620 nm via spectrophotometry. After the experiments, BBB tissue samples were collected from the right and left brains of all rabbits in the three groups and subjected to a series of medical procedures. Samples from Group 1 were compared with those from Group 2 and Group 3 using statistical methods to determine if there were any significant differences. As a result, it was found that there was no statistically significant difference in the BBB of rabbits exposed to 1800 MHz radiation, whereas there was a statistically significant difference at a 95% confidence level in the BBB of rabbits exposed to 2100 MHz radiation. A decrease in EB values was observed upon the arithmetic examination of the BBB.
引用
收藏
页码:915 / 932
页数:18
相关论文
共 33 条
  • [21] Appraisal of immediate and late effects of mobile phone radiations at 2100 MHz on mitotic activity and DNA integrity in root meristems of Allium cepa
    Chandel, Shikha
    Kaur, Shalinder
    Issa, Mohd
    Singh, Harminder Pal
    Batish, Daizy Rani
    Kohli, Ravinder Kumar
    PROTOPLASMA, 2019, 256 (05) : 1399 - 1407
  • [22] Hippocampal lipidome and transcriptome profile alterations triggered by acute exposure of mice to GSM 1800 MHz mobile phone radiation: An exploratory study
    Fragopoulou, Adamantia F.
    Polyzos, Alexandros
    Papadopoulou, Maria-Despoina
    Sansone, Anna
    Manta, Areti K.
    Balafas, Evangelos
    Kostomitsopoulos, Nikolaos
    Skouroliakou, Aikaterini
    Chatgilialoglu, Chryssostomos
    Georgakilas, Alexandros
    Stravopodis, Dimitrios J.
    Ferreri, Carla
    Thanos, Dimitris
    Margaritis, Lukas H.
    BRAIN AND BEHAVIOR, 2018, 8 (06):
  • [23] Effects of Long Term Exposure of 900-1800 MHz Radiation Emitted from 2G Mobile Phone on Mice Hippocampus-A Histomorphometric Study
    Mugunthan, Narayanaperumal
    Shanmugasamy, Kathirvelu
    Anbalagan, Jayaram
    Rajanarayanan, Swamynathan
    Meenachi, Swamynathan
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (08) : AF1 - AF6
  • [24] Effects of lipopolysaccharide on the radiation-induced changes in the blood-brain barrier and the astrocytes
    Kaya, M
    Palanduz, A
    Kalayci, R
    Kemikler, G
    Simsek, G
    Bilgic, B
    Ahishali, B
    Arican, N
    Kocyildiz, ZC
    Elmas, L
    Kucuk, M
    Karadeniz, A
    BRAIN RESEARCH, 2004, 1019 (1-2) : 105 - 112
  • [25] OBSERVED EFFECTS OF WHOLE -BRAIN RADIATION THERAPY ON FOCUSED ULTRASOUND BLOOD-BRAIN BARRIER DISRUPTION
    White, Phillip Jason
    Zhang, Yong-Zhi
    Power, Chanikarn
    Vykhodtseva, Natalia
    McDannold, Nathan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (08) : 1998 - 2006
  • [26] Exposure to 900 MHz electromagnetic fields activates the mkp-1/ERK pathway and causes blood-brain barrier damage and cognitive impairment in rats
    Tang, Jun
    Zhang, Yuan
    Yang, Liming
    Chen, Qianwei
    Tan, Liang
    Zuo, Shilun
    Feng, Hua
    Chen, Zhi
    Zhu, Gang
    BRAIN RESEARCH, 2015, 1601 : 92 - 101
  • [27] Effects of fractionated radiation on the brain vasculature in a murine model: Blood-brain barrier permeability, astrocyte proliferation, and ultrastructural changes
    Yuan, Hong
    Gaber, M. Waleep
    Boyd, Kelli
    Wilson, Christy M.
    Kiani, Mohammad F.
    Merchant, Thomas E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : 860 - 866
  • [28] Effects of whole-brain radiation therapy on the blood-brain barrier in immunocompetent and immunocompromised mouse models
    Blethen, K. E.
    Sprowls, S. A.
    Arsiwala, T. A.
    Wolford, C. P.
    Panchal, D. M.
    Fladeland, R. A.
    Glass, M. J.
    Dykstra, L. P.
    Kielkowski, B. N.
    Blackburn, J. R.
    Andrick, C. J.
    Lockman, P. R.
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [29] Long-term effects of 900 MHz radiofrequency radiation emitted from mobile phone on testicular tissue and epididymal semen quality
    Tas, Muzaffer
    Dasdag, Suleyman
    Akdag, Mehmet Zulkuf
    Cirit, Umut
    Yegin, Korkut
    Seker, Ugur
    Ozmen, Mehmet Ferit
    Eren, Leyla Bilge
    ELECTROMAGNETIC BIOLOGY AND MEDICINE, 2014, 33 (03) : 216 - 222
  • [30] Multiple Low-Pressure Sonications to Improve Safety of Focused-Ultrasound Induced Blood-Brain Barrier Disruption: In a 1.5-MHz Transducer Setup
    Hsu, P. H.
    Wang, J. J.
    Lin, K. J.
    Chen, J. C.
    Liu, H. L.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 547 - +