Three-dimensional digital imaging analysis of the palatal bone thickness for orthodontic mini-implant insertion - determination of the safe zone and angulation

被引:0
作者
Schubert, Hanna [1 ]
Matta, Ragai [2 ]
Seidel, Anna [2 ]
Adler, Werner [3 ]
Wichmann, Manfred [2 ]
Kesting, Marco [1 ]
Lutz, Rainer [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Oral & Craniomaxillofacial Surg, Gluckstr 11, D-91054 Erlangen, Germany
[2] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Prosthodont, Erlangen, Germany
[3] Friedrich Alexander Univ Erlangen Nurnberg FAU, Dept Med Informat Biometry & Epidemiol, Erlangen, Germany
来源
BMC ORAL HEALTH | 2024年 / 24卷 / 01期
关键词
Three-dimensional; Palate; Cone-beam computed tomography; Temporary anchorage devices; Orthodontic anchorage procedures; PRIMARY STABILITY; ANTERIOR PALATE; SUCCESS RATES; ANCHORAGE; RADIOGRAPHS; POSITION; MINISCREWS; PLACEMENT; MAXILLA; IMPACT;
D O I
10.1186/s12903-024-05229-y
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundIn order to successfully perform orthodontic mini-implant procedures successfully for the subsequent anchoring of orthodontic appliances, it is crucial to know the palatal bone thickness. This is usually assessed using two-dimensional radiographs. The purpose of this study was to use a three-dimensional digital imaging measurement method to provide information on palatal bone volume and bone thickness and to make recommendations on the optimal and safe insertion site and angle for palatal mini-implants.MethodsFor this observational, cross-section study, pre-existing cone beam computed tomography scans of 184 patients were converted into 3D Standard Tessellation Language (STL) models of the maxilla. The area between the canine and the first molar was divided into 6 regions of interest (ROIs), three on the left side of the palate and three on the right side. The bone thickness of the palate was analyzed volumetrically and linearly while simulating different mini-implant insertion angles of 0 degrees, 10 degrees, 20 degrees and 30 degrees degrees relative to the palatal surface.ResultsAmong the ROIs, the greatest mean bone thickness was observed in the region of the first premolars with a mean distance (MD) of 10.44 +/- 2.53 mm and decreased from anterior to posterior (MD: 3.44 +/- 1.16 mm). The highest volume (Vol) values were also measured in the anterior palatal region (Vol: 1127.26 +/- 483.91 mm3), while there was also a decrease in the posterior region (Vol: 394.36 +/- 180.22 mm3). Regarding the simulated palatal mini-implant insertion sites, the greatest bone thickness was found in the anterior region, at the level of the canines with an angle of 0 degrees (MD: 12.25 +/- 3.75 mm). In the more posterior region, at the level between the first and second premolars, the greatest bone thickness was observed at an angle of 30 degrees (MD: 7.93 +/- 3.81 mm). Gender differences were found.ConclusionThis clinical study showed that the paramedian region at the level of the first premolar is the safest site for orthodontic mini-implant placement as evaluated by three-dimensional measurements. The results showed that implant insertion angle, gender and age are important aspects to consider when planning and inserting orthodontic palatal mini-implants.Trial registrationN.a.
引用
收藏
页数:14
相关论文
共 69 条
  • [1] Evaluation of mini-implant sites in the posterior maxilla using traditional radiographs and cone-beam computed tomography
    Abbassy, Mona A.
    Sabban, Hanady M.
    Hassan, Ali H.
    Zawawi, Khalid H.
    [J]. SAUDI MEDICAL JOURNAL, 2015, 36 (11) : 1336 - 1341
  • [2] Annibali S, 2008, Oral Implantol (Rome), V1, P21
  • [3] Asscherickx K, 2005, ANGLE ORTHOD, V75, P826
  • [4] Clinical observations and success rates of palatal implants
    Asscherickx, Karlien
    Vannet, Bart Vande
    Bottenberg, Peter
    Wehrbein, Heiner
    Sabzevar, Mehran Moradi
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (01) : 114 - 122
  • [5] Is there an ideal insertion angle and position for orthodontic mini-implants in the anterior palate? A CBCT study in humans
    Becker, Kathrin
    Unland, Justine
    Wilmes, Benedict
    Tarraf, Nour Eldin
    Drescher, Dieter
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2019, 156 (03) : 345 - 354
  • [6] BERGERSEN EO, 1980, ANGLE ORTHOD, V50, P230
  • [7] Caetano Gabriela-Franco-da Rosa, 2022, J Clin Exp Dent, V14, pe669, DOI 10.4317/jced.59384
  • [8] Evaluation of total bone and cortical bone thickness of the palate for temporary anchorage device insertion
    Chang, Chen-Jung
    Lin, Wei-Cheng
    Chen, Meng-Yen
    Chang, Hung-Chih
    [J]. JOURNAL OF DENTAL SCIENCES, 2021, 16 (02) : 636 - 642
  • [9] Three-dimensional quantitative assessment of palatal bone height for insertion of orthodontic implants - a retrospective CBCT study
    Chhatwani, Sachin
    Rose-Zierau, Viola
    Haddad, Bassel
    Almuzian, Mohammed
    Kirschneck, Christian
    Danesh, Gholamreza
    [J]. HEAD & FACE MEDICINE, 2019, 15
  • [10] Nonsurgical miniscrew-assisted rapid maxillary expansion results in acceptable stability in young adults
    Choi, Sung-Hwan
    Shi, Kyung-Keun
    Cha, Jung-Yul
    Park, Young-Chel
    Lee, Kee-Joon
    [J]. ANGLE ORTHODONTIST, 2016, 86 (05) : 713 - 720