Amaranth; Ponceau; 4R; Ag-ErGO/AuE; Adsorptive stripping voltammetry; Cyclic voltammetry; SYNTHETIC FOOD COLORANTS; PARTIAL LEAST-SQUARES; SENSITIVE DETERMINATION; HUMMERS METHOD; ALLURA RED; DYES; ISOMERS; DRINKS; WATER; HPLC;
D O I
10.1007/s00396-024-05355-7
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Ponceau 4R and amaranth are synthetic azo dyes commonly used in the food and beverage industry. However, excessive consumption of these dyes can pose potential health risks. This study describes a novel electrochemical sensor based on an electrochemical-reduced graphene oxide and silver (Ag-ErGO) modified gold electrode for the simultaneous determination of ponceau 4R and amaranth in soft drinks. The sensor was fabricated by electrochemically reducing graphene oxide and silver ion on a gold electrode (AuE). The morphology, structure, and composition of Ag-ErGO and graphene oxide on the gold electrode surface were characterized using SEM, IR spectroscopy, and EDS analysis. Adsorptive stripping voltammetry (AdSV) combined with cyclic voltammetry (CV) was employed to investigate the electrochemical behavior of ponceau 4R and amaranth. The optimal conditions were chosen to be Britton-Robinson buffer pH 2.0, adsorption potential 0.5 V, adsorption time 60 s, and scan rate 12.5 mV/s. The linearity ranges were from 0.0302 to 0.2418 mg<middle dot>L-1 and 0.0604 to 0.4836 mg<middle dot>L-1 with the detection limits 0.0074 mg<middle dot>L-1 and 0.0188 mg<middle dot>L-1 for simultaneously determination of ponceau 4R and amaranth, respectively. The proposed method was successfully applied to determine ponceau 4R and amaranth in soft drink samples.
引用
收藏
页码:359 / 373
页数:15
相关论文
共 50 条
  • [21] Voltammetric dopamine sensor based on a gold electrode modified with reduced graphene oxide and Mn3O4 on gold nanoparticles
    Yao, Zufu
    Yang, Xin
    Niu, Youya
    Wu, Feng
    Hu, Yangjian
    Yang, Yaqi
    MICROCHIMICA ACTA, 2017, 184 (07) : 2081 - 2088
  • [22] Electrochemical sensor based on graphene doped gold nanoparticles modified electrode for detection of diethylstilboestrol
    Ma, Xinying
    Chen, Meifeng
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 215 : 445 - 450
  • [23] Electrochemical Study of Allura Red at Glassy Carbon Electrode Modified with the Reduced Graphene Oxide and Its Determination in Food by Adsorptive Stripping Voltammetry
    Le, Thi Hurong Giang
    Nguyen, Thi Mai
    Pham, Thi Thanh Nhan
    Do, Trong Bang
    Dang, Minh Huong Giang
    Nguyen, Thi Kim Thuong
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (05): : 371 - 381
  • [24] Carbon Paper Modified with Functionalized Poly(diallyldimethylammonium chloride) Graphene and Gold Phytonanoparticles as a Promising Sensing Material: Characterization and Electroanalysis of Ponceau 4R in Food Samples
    Stozhko, Natalia Yu.
    Khamzina, Ekaterina I. I.
    Bukharinova, Maria A. A.
    Tarasov, Aleksey V. V.
    Kolotygina, Veronika Yu.
    Lakiza, Natalia V. V.
    Kuznetcova, Ekaterina D. D.
    NANOMATERIALS, 2022, 12 (23)
  • [25] Electrochemical detection of pyrosine with electrochemically reduced graphene oxide modified glassy carbon electrode
    Kong, Yong
    Ren, Xiaolin
    Huo, Zongli
    Wang, Guoxin
    Tao, Yongxin
    Yao, Chao
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2013, 236 (06) : 955 - 961
  • [26] Electrochemical Determination of Propranolol using Reduced Graphene Oxide Modified Carbon Paste Electrode
    Purushothama, Hanumasagara Thimmappa
    Nayaka, Yanjerappa Arthoba
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (11): : 1575 - 1589
  • [27] Electrochemical Sensor for Determination of Paracetamol Based on Reduced Graphene Oxide/Polypyrrole Nanotubes Nanocomposite Modified Screen Printed Electrode in Pharmaceutical Samples
    Jahani, Peyman Mohammadzadeh
    Zaimbashi, Reza
    Tajik, Somayeh
    Beitollahi, Hadi
    CHEMICAL METHODOLOGIES, 2025, 9 (04): : 251 - 267
  • [28] An electrochemical sensor for the determination of bisphenol A using glassy carbon electrode modified with reduced graphene oxide-silver/poly-L-lysine nanocomposites
    Li, Yahui
    Wang, Haoqiang
    Yan, Bo
    Zhang, Huayu
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 805 : 39 - 46
  • [29] Simultaneous Determination of Carmine and Amaranth Based on a Poly(L-Arginine)-Graphene Modified Electrode
    Hu, Q. Q.
    Gao, H.
    Wang, Y. M.
    Ma, W.
    Sun, D. M.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 73 (08) : 817 - 823
  • [30] Reduced Graphene Oxide and Poly (phenylalanine) Composite Modified Electrode for the Electrochemical Determination of Vanillin
    Tesfaye, Gizaw
    Negash, Negussie
    Tessema, Merid
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (12)