Performance optimization of new generation R290 and R1234yf refrigerants: A response surface methodology approach

被引:0
作者
Pektezel, Oguzhan [1 ]
Ozdemir, Safiye Nur [2 ]
机构
[1] Univ Balikesir, Dept Mech Engn, TR-10145 Balikesir, Turkiye
[2] Univ Sakarya, Dept Mech Engn, TR-54050 Adapazari, Turkiye
关键词
Experimental refrigeration system; Central composite design; Response surface methodology; Desirability function approach; Optimization process; MULTIOBJECTIVE OPTIMIZATION; ENERGY PERFORMANCE; GWP MIXTURES; SYSTEM; R134A; REPLACEMENT; IMPROVEMENT; R404A; ALTERNATIVES; R513A;
D O I
10.1016/j.applthermaleng.2025.125927
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study aims to perform the parametric optimization of the R290 and R1234yf refrigerants in vapor compression refrigeration systems by employing the Response surface methodology (RSM) approach to obtain the best operating conditions. The input factors, including evaporator and condenser temperatures, are first determined, ranging from -12 to -4 degrees C and 30 to 40 degrees C, respectively. The objective functions are also identified, including compressor discharge temperature (Tdis), refrigerant mass flow rate (mref), compressor power consumption (Pcomp), and coefficient of performance (COP). Then, the central composite design (CCD) was performed to set out the experimental investigations. Response surface methodology and analysis of variance were utilized to detect the optimal levels and analyze the individual and combined interaction between each pair of input factors. The novelty of this study is in applying the RSM technique to develop second-order regression models and utilizing the desirability function approach for optimizing the refrigeration system. The deviations between the predicted and experimental values for the compressor discharge temperature, refrigerant mass flow rate, compressor power consumption, and COP are 0.256 %, 0.292 %, 0.724 %, and 0.169 %, respectively, representing that this method efficiently optimizes the performance of the R290 refrigerant. Similarly, the deviations between the predicted and experimental values for R1234yf are as follows: 0.272 %, 0.526 %, 0.980 %, and 1.069 %. From our knowledge, there have been very few optimization studies on the thermodynamic performance of refrigerants using the RSM tool, which reduces experimental costs and saves time.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Experimental study of falling film evaporation of refrigerants, R32 R1234yf, R410A, R452B and R454B on horizontal tubes
    Hsu, Chien-Yeh
    Chien, Liang-Han
    Chang, Jan-Cheng
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 205
  • [42] Comparative performance of an automobile heat pump system with an internal heat exchanger using R1234yf and R134a
    Tasdemirci E.
    Alptekin E.
    Hosoz M.
    International Journal of Exergy, 2020, 33 (01): : 98 - 113
  • [43] A COMPARISON OF THE ENERGY AND EXERGY PERFORMANCE OF R1234YF AND R134a IN A COMPRESSION STAGE USING COMPUTATIONAL INTELLIGENCE TECHNIQUES
    Barroso Maldonado, Juan Manuel
    Belman Flores, Juan Manuel
    Gallegos Munoz, Armando
    Navarro Esbri, Joaquin
    Ledesma Orozco, Sergio
    1ST IIR INTERNATIONAL CONFERENCE ON THE APPLICATION OF HFO REFRIGERANTS, 2018, : 170 - 177
  • [44] Comparative performance of an automobile heat pump system with an internal heat exchanger using R1234yf and R134a
    Tasdemirci, Erkutay
    Alptekin, Ertan
    Hosoz, Murat
    INTERNATIONAL JOURNAL OF EXERGY, 2020, 33 (01) : 98 - 113
  • [45] R152a-R13I1 mixture as an alternative to R1234yf for a mobile air conditioning: an estimation of flammability properties, thermodynamic and environmental performance
    Mayakrishnan, Chelliah
    Prabakaran, Rajendran
    Lal, Dhasan Mohan
    Kim, Sung Chul
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (22) : 13095 - 13115
  • [46] Transitioning to low GWP refrigerants in automobiles: A numerical simulation study on R1234yf/R152a's heat transfer characteristics in porous microchannels
    He, Tianbiao
    Zeng, Xiangwei
    Qi, Meng
    Mao, Ning
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2024,
  • [47] Comparative investigation and multi objective design optimization of R744/R717, R744/R134a and R744/R1234yf cascade rerfigeration systems
    Turgut, Mert Sinan
    Turgut, Oguz Emrah
    HEAT AND MASS TRANSFER, 2019, 55 (02) : 445 - 465
  • [48] Performance and energy evaluation of R450A, R1234yf, R513A, R516A, R152A, and R1234ze(E) as alternatives to R134A in an air conditioner
    Hussain, Zakir
    You, Nayoung
    Cho, Honghyun
    APPLIED THERMAL ENGINEERING, 2025, 271
  • [49] Drop-in Performance Analysis and Effect of IHX for an Automotive Air Conditioning System with R1234yf as a Replacement of R134a
    Direk, Mehmet
    Kelesoglu, Alper
    Akin, Ahmet
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2017, 63 (05): : 314 - 319
  • [50] Experimental performance comparison of R1234yf and R134a automobile air conditioning systems employing a variable capacity compressor
    Tasdemirci, Erkutay
    Alptekin, Ertan
    Hosoz, Murat
    INTERNATIONAL JOURNAL OF VEHICLE DESIGN, 2022, 90 (1-4) : 1 - 18