Performance optimization of new generation R290 and R1234yf refrigerants: A response surface methodology approach

被引:0
|
作者
Pektezel, Oguzhan [1 ]
Ozdemir, Safiye Nur [2 ]
机构
[1] Univ Balikesir, Dept Mech Engn, TR-10145 Balikesir, Turkiye
[2] Univ Sakarya, Dept Mech Engn, TR-54050 Adapazari, Turkiye
关键词
Experimental refrigeration system; Central composite design; Response surface methodology; Desirability function approach; Optimization process; MULTIOBJECTIVE OPTIMIZATION; ENERGY PERFORMANCE; GWP MIXTURES; SYSTEM; R134A; REPLACEMENT; IMPROVEMENT; R404A; ALTERNATIVES; R513A;
D O I
10.1016/j.applthermaleng.2025.125927
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study aims to perform the parametric optimization of the R290 and R1234yf refrigerants in vapor compression refrigeration systems by employing the Response surface methodology (RSM) approach to obtain the best operating conditions. The input factors, including evaporator and condenser temperatures, are first determined, ranging from -12 to -4 degrees C and 30 to 40 degrees C, respectively. The objective functions are also identified, including compressor discharge temperature (Tdis), refrigerant mass flow rate (mref), compressor power consumption (Pcomp), and coefficient of performance (COP). Then, the central composite design (CCD) was performed to set out the experimental investigations. Response surface methodology and analysis of variance were utilized to detect the optimal levels and analyze the individual and combined interaction between each pair of input factors. The novelty of this study is in applying the RSM technique to develop second-order regression models and utilizing the desirability function approach for optimizing the refrigeration system. The deviations between the predicted and experimental values for the compressor discharge temperature, refrigerant mass flow rate, compressor power consumption, and COP are 0.256 %, 0.292 %, 0.724 %, and 0.169 %, respectively, representing that this method efficiently optimizes the performance of the R290 refrigerant. Similarly, the deviations between the predicted and experimental values for R1234yf are as follows: 0.272 %, 0.526 %, 0.980 %, and 1.069 %. From our knowledge, there have been very few optimization studies on the thermodynamic performance of refrigerants using the RSM tool, which reduces experimental costs and saves time.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] EMPIRICAL CORRELATIONS FOR THE PERFORMANCE OF AN AUTOMOTIVE AIR CONDITIONING SYSTEM USING R1234yf AND R134a
    Aral, Mumin Celil
    Hosoz, Murat
    Subermanto, Mukhamad
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2017, 37 (01) : 127 - 137
  • [32] Experimental Performance Analysis of R1234yf in an Air-Conditioning System as Substitute of R134a
    Medany, M. M.
    El Morsi, M.
    El-Sayed, A. R.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2021, 29 (04)
  • [33] Exergoeconomic performance comparison of R1234yf as a drop-in replacement for R134a in a domestic refrigerator
    Rangel-Hernandez, V. H.
    Belman-Flores, J. M.
    Rodriguez-Valderrama, D. A.
    Pardo-Cely, D.
    Rodriguez-Munoz, A. P.
    Ramirez-Minguela, J. J.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 100 : 113 - 123
  • [34] PERFORMANCE OF R1234yf AND R513A AS ALTERNATIVES TO R134a IN AUTOMOTIVE AIR CONDITIONING SYSTEMS IN WINTER
    Meng, Zhaofeng
    Cui, Xiangna
    Liu, Yin
    Wang, Shun
    DU, Chenyang
    Hu, Rusheng
    THERMAL SCIENCE, 2023, 27 (3A): : 1937 - 1946
  • [35] Comparison of the Straight Adiabatic Capillary Tube Expansion Devices Used in Refrigeration Systems Operating With Refrigerants R134a and R1234yf
    Kruthiventi, S. S. Harish
    Venkatarathnam, G.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2016, 8 (02)
  • [36] Performance improvement strategies of R1234yf in vapor compression refrigeration system as a R134a replacement: A review
    Sharif, M. Z.
    Azmi, W. H.
    Ghazali, M. F.
    Samykano, M.
    Ali, Hafiz Muhammad
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2023, 148
  • [37] Performance evaluation of R1234yf heat pump system for an electric vehicle in cold climate
    Li, Wanyong
    Liu, Rui
    Liu, Yusheng
    Wang, Dandong
    Shi, Junye
    Chen, Jiangping
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 115 : 117 - 125
  • [38] Pressure Drop and Heat Transfer Characteristics of TiO2/R1234yf Nanorefrigerant: A Numerical Approach
    Bibin, B. S.
    Gundabattini, Edison
    SUSTAINABILITY, 2023, 15 (16)
  • [39] Experimental investigation of a two-phase ejector cycle suitable for use with low-pressure refrigerants R134a and R1234yf
    Lawrence, Neal
    Elbel, Stefan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 38 : 310 - 322
  • [40] Design optimization of external variable displacement compressor with R1234yf for vehicle air conditioning system
    Lee, Taejin
    Shin, Kyeong-Ho
    Kim, Jihyun
    Jung, Dongsoo
    Kim, Joo-Hyung
    APPLIED THERMAL ENGINEERING, 2021, 198