Periodic detection and disinfection maintenance of dental unit waterlines in dental simulation head model laboratories

被引:0
作者
Li, Biyao [1 ]
Hu, Yuya [1 ]
Wang, Yiqi [1 ]
Zhang, Chengqi [1 ]
Wang, Zimo [1 ]
Peng, Xujie [1 ]
Feng, Jianying [1 ,2 ]
机构
[1] Zhejiang Chinese Med Univ, Sch Stomatol, Hangzhou, Zhejiang, Peoples R China
[2] Zhejiang Chinese Med Univ, Sch Hosp Stomatol, Dept Stomatol, Hangzhou, Zhejiang, Peoples R China
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Dental simulation head model laboratory; Dental unit waterlines; Microbial contamination; Organochlorine disinfectant; Chlorine dioxide; High-throughput sequencing; CONTAMINATION; DIVERSITY; BIOFILMS; EFFICACY; QUALITY;
D O I
10.1038/s41598-025-89010-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Dental simulation head model laboratories are crucial for clinical simulation training for stomatological students, yet the maintenance of their dental unit waterlines (DUWLs) has been overlooked. This study investigated water contamination in DUWLs within these laboratories and proposed solutions. Water samples were collected from 12 dental chairs in three laboratories at three time points: the beginning, middle, and end of the semester. At the start of the semester, severe contamination was observed, with colony counts of 11,586\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\:\pm\:$$\end{document}1715 CFU/ml for high-speed handpieces and 5375\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\:\pm\:$$\end{document}874 CFU/ml for three ways syringes. As the semester progressed, colony counts gradually decreased but remained above clinical thresholds. Both 20 mg/L organochlorine disinfectant and 20 mg/L chlorine dioxide were effective in reducing bacterial contamination below standard ranges three days post-disinfection. Microbial diversity analysis revealed Proteobacteria and Bacteroidota as the dominant bacterial phyla, with Ascomycota as the dominant fungal phylum. Potentially pathogenic bacteria such as Pseudomonas, Burkholderia-Caballeronia-Paraburkholderia, Ralstonia, Mycobacterium, Legionella, Paenibacillus, Streptomyces, Acinetobacter, and Prevotella, as well as fungi like Fusarium and Penicillium, were detected. Therefore, urgent attention is needed to address DUWL contamination in dental laboratories, and it is recommended to disinfect DUWLs using either 20 mg/L organochlorine disinfectant or 20 mg/L chlorine dioxide every three days.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] COLONIZATION OF LEGIONELLA SPP. IN DENTAL UNIT WATERLINES
    Carinci, F.
    Scapoli, L.
    Contaldo, M.
    Santoro, R.
    Palmieri, A.
    Pezzetti, F.
    Lauritano, D.
    Candotto, V.
    Mucchi, D.
    Baggi, L.
    Tagliabue, A.
    Tettamanti, L.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2018, 32 (02) : 139 - 142
  • [42] Pyrosequencing analysis of bacterial diversity in dental unit waterlines
    Costa, Damien
    Mercier, Anne
    Gravouil, Kevin
    Lesobre, Jerome
    Delafont, Vincent
    Bousseau, Anne
    Verdon, Julien
    Imbert, Christine
    WATER RESEARCH, 2015, 81 : 223 - 231
  • [43] Biofilms, infectious agents, and dental unit waterlines: a review
    Barbeau, J
    Gauthier, C
    Payment, P
    CANADIAN JOURNAL OF MICROBIOLOGY, 1998, 44 (11) : 1019 - 1028
  • [44] Developing an ecologically relevant heterogeneous biofilm model for dental-unit waterlines
    Lal, Sham
    Pearce, Mark
    Achilles-Day, Undine E. M.
    Day, John G.
    Morton, L. H. Glyn
    Crean, St John
    Singhrao, Sim K.
    BIOFOULING, 2017, 33 (01) : 75 - 87
  • [45] Microbial contamination of dental unit waterlines and effect on quality of indoor air
    Duygu Göksay Kadaifciler
    Aysin Cotuk
    Environmental Monitoring and Assessment, 2014, 186 : 3431 - 3444
  • [46] Evaluation of the antimicrobial effect of silver ion tubing on dental unit waterlines
    Cheng, Lanxin
    Liu, Tianshu
    Liang, Shimin
    Dai, Yuhua
    Zhu, Zhuoli
    AMERICAN JOURNAL OF DENTISTRY, 2021, 34 (04) : 228 - 232
  • [47] Distribution of nontuberculous mycobacteria in dental unit waterlines: A potential health hazard in the dental office
    Vosooghi, Kimia
    Larypoor, Mohaddeseh
    Sakhaee, Fatemeh
    Jajin, Morteza Ghazanfari
    Moghaddam, Sina
    Samieefar, Noosha
    Keramat, Reza Rahbari
    Sabotki, Mohsen Amiri
    Fateh, Abolfazl
    MICROBIAL PATHOGENESIS, 2024, 196
  • [48] Dental Unit Waterlines: A Survey of Practices in Eastern France
    Baudet, Alexandre
    Lizon, Julie
    Martrette, Jean-Marc
    Camelot, Frederic
    Florentin, Arnaud
    Clement, Celine
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (21)
  • [49] Electron microscopic examination of dental unit waterlines biofilm
    Szymanska, J
    ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2005, 12 (02) : 295 - 298
  • [50] Establishing a laboratory model of dental unit waterlines bacterial biofilms using a CDC biofilm reactor
    Yoon, Hye Young
    Lee, Si Young
    BIOFOULING, 2017, 33 (10) : 917 - 926