Periodic detection and disinfection maintenance of dental unit waterlines in dental simulation head model laboratories

被引:0
|
作者
Li, Biyao [1 ]
Hu, Yuya [1 ]
Wang, Yiqi [1 ]
Zhang, Chengqi [1 ]
Wang, Zimo [1 ]
Peng, Xujie [1 ]
Feng, Jianying [1 ,2 ]
机构
[1] Zhejiang Chinese Med Univ, Sch Stomatol, Hangzhou, Zhejiang, Peoples R China
[2] Zhejiang Chinese Med Univ, Sch Hosp Stomatol, Dept Stomatol, Hangzhou, Zhejiang, Peoples R China
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Dental simulation head model laboratory; Dental unit waterlines; Microbial contamination; Organochlorine disinfectant; Chlorine dioxide; High-throughput sequencing; CONTAMINATION; DIVERSITY; BIOFILMS; EFFICACY; QUALITY;
D O I
10.1038/s41598-025-89010-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Dental simulation head model laboratories are crucial for clinical simulation training for stomatological students, yet the maintenance of their dental unit waterlines (DUWLs) has been overlooked. This study investigated water contamination in DUWLs within these laboratories and proposed solutions. Water samples were collected from 12 dental chairs in three laboratories at three time points: the beginning, middle, and end of the semester. At the start of the semester, severe contamination was observed, with colony counts of 11,586\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\:\pm\:$$\end{document}1715 CFU/ml for high-speed handpieces and 5375\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\:\pm\:$$\end{document}874 CFU/ml for three ways syringes. As the semester progressed, colony counts gradually decreased but remained above clinical thresholds. Both 20 mg/L organochlorine disinfectant and 20 mg/L chlorine dioxide were effective in reducing bacterial contamination below standard ranges three days post-disinfection. Microbial diversity analysis revealed Proteobacteria and Bacteroidota as the dominant bacterial phyla, with Ascomycota as the dominant fungal phylum. Potentially pathogenic bacteria such as Pseudomonas, Burkholderia-Caballeronia-Paraburkholderia, Ralstonia, Mycobacterium, Legionella, Paenibacillus, Streptomyces, Acinetobacter, and Prevotella, as well as fungi like Fusarium and Penicillium, were detected. Therefore, urgent attention is needed to address DUWL contamination in dental laboratories, and it is recommended to disinfect DUWLs using either 20 mg/L organochlorine disinfectant or 20 mg/L chlorine dioxide every three days.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Microbial contamination of dental unit waterlines and effect on quality of indoor air
    Kadaifciler, Duygu Goksay
    Cotuk, Aysin
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2014, 186 (06) : 3431 - 3444
  • [32] Biofilm growth and microbial contamination of dental unit waterlines at Kuwait University dental center
    Akbar, Jaber Hussain
    Behbehani, Jawad
    Karched, Maribasappa
    FRONTIERS IN ORAL HEALTH, 2023, 3
  • [33] Formation and decontamination of biofilms in dental unit waterlines
    Wirthlin, MR
    Marshall, GW
    Rowland, RW
    JOURNAL OF PERIODONTOLOGY, 2003, 74 (11) : 1595 - 1609
  • [34] Corrosion Behaviors of Disinfectants on Dental Unit Waterlines
    Ling Zhang
    Jiajun Qiu
    Min Xing
    Wenhao Qian
    Journal of Wuhan University of Technology-Mater. Sci. Ed., 2023, 38 : 938 - 941
  • [35] The Optimum Duration of Flushing Dental Unit Waterlines for Microbial Removal
    Hon, John Chong Keat
    Adnan, Siti Noor Adnalizawati
    Ismail, Nur Aqilah
    ARCHIVES OF OROFACIAL SCIENCE, 2021, 16 (01): : 13 - 23
  • [36] Control of microbial contamination in dental unit waterlines: Effectiveness of neutral electrolytic water
    Mishima, Sayaka
    Watanabe, Takuma
    Fukuhara, Shizuko
    Ymanaka, Shigeki
    Nakao, Kazumasa
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY MEDICINE AND PATHOLOGY, 2025, 37 (03) : 512 - 517
  • [37] Susceptibility of bacteria isolated from dental unit waterlines to disinfecting chemical agents
    Yoon, Hye Young
    Lee, Si Young
    JOURNAL OF GENERAL AND APPLIED MICROBIOLOGY, 2018, 64 (06) : 269 - 275
  • [38] Evaluation of NaOCl 0.2% Solution for Disinfection of Dental Equipment Waterlines
    Claudin, Dikson
    Teixeira Lima, Amanda de Moraes
    Botega, Talita Anacleto
    Prudencio Serratine, Ana Claudina
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2011, 11 (04): : 471 - 476
  • [39] Colonization of Dental Unit Waterlines by Helicobacter pylori: Risk of Exposure in Dental Practices
    Giacomuzzi, Monica
    Zotti, Carla M.
    Ditommaso, Savina
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (16)
  • [40] Efficacy of dental unit waterlines disinfectants on a polymicrobial biofilm
    Costa, Damien
    Girardot, Marion
    Bertaux, Joanne
    Verdon, Julien
    Imbert, Christine
    WATER RESEARCH, 2016, 91 : 38 - 44