Partial Discharge Aging of Epoxy Insulation at Different High-Frequency Pulse Parameters and Environmental Stresses

被引:2
作者
Shang, Xingyu [1 ]
Pang, Lei [1 ]
Bu, Qinhao [1 ]
Zhang, Qiaogen [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Insulation; Voltage; Humidity; Aging; Stress; Partial discharges; Voltage measurement; Frequency measurement; Electrodes; Discharges (electric); Electrical aging; environmental stress; epoxy insulation; high-frequency (HF) pulse voltage; lifetime; partial discharge (PD); ENAMELED WIRES; TIME; DEGRADATION; BREAKDOWN; LIFE; MECHANISMS; PREDICTION; MACHINES; FAILURE; GAP;
D O I
10.1109/TDEI.2024.3502581
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The voltage stress on high-frequency transformers (HFTs) features higher levels of repetition frequency, operating voltage, voltage dV/dt, and grid voltage superposition, which challenges the epoxy insulation of HFTs exposed to partial discharges (PDs). Wide ranges of voltage parameters (frequency, voltage, rising edge, and dc bias) and environmental stresses (temperature, humidity, gas, and pressure) are applied to the sphere-gap-insulation-plate structure for PD aging analysis. New patterns are found in this study. For example, the shape of the rising edge affects the lifetime, and the influences of humidity and dc bias are nonmonotonic. Surface charge decay and voltage dV/dt have key effects on the discharge pattern. Early failures with pulse frequencies of 50 and 100 kHz are attributed to the interaction of humidity and electric field. The erosion rate is lower at oxygen-free ambient, while higher with CO2 gas. PD parameters (PD number, PD amplitude, PD delay, PD ignition voltage, and PD frequency) and phase-resolved PD (PRPD) patterns are measured with the ultrahigh-frequency (UHF) method and discussed for all aging conditions. Cumulative PD amplitude and cumulative PD energy have a good correlation to experimental lifetime values. However, due to the transition of the PD regime, the fit model has less explainability on the influence of voltage, humidity, gas, and pressure on the lifetime, which is rarely revealed before.
引用
收藏
页码:45 / 54
页数:10
相关论文
共 51 条
[1]   Impact of impulse voltage frequency on the partial discharge characteristic of electric vehicles motor insulation [J].
Akram, Shakeel ;
Wang, Peng ;
Nazir, M. Tariq ;
Zhou, Kai ;
Bhutta, M. Shoaib ;
Hussain, Haider .
ENGINEERING FAILURE ANALYSIS, 2020, 116
[2]   EFFECT OF OVERVOLTAGE ON THE RISETIME AND AMPLITUDE OF PD PULSES [J].
BARTNIKAS, R ;
NOVAK, JP .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1995, 2 (04) :557-566
[3]  
Dissado L.A., 1992, Electrical degradation and breakdown in polymers, P9
[4]   Relation between space charge accumulation and partial discharge activity in enameled wires under PWM-like voltage waveforms [J].
Fabiani, D ;
Montanari, GC ;
Cavallini, A ;
Mazzanti, G .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2004, 11 (03) :393-405
[5]  
Fabiani D., 2003, Ph.D. thesis
[6]  
Farber R., 2019, Endurance of polymeric insulation under mixed-frequency medium-voltage stress
[7]   Streamer inception thresholds derived from a statistical electron transport model [J].
Farber, Raphael ;
Franck, Christian M. .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2021, 54 (43)
[8]  
Gradinger TB, 2017, EUR CONF POW ELECTR
[9]  
Guastavino F., 2009, 2009 IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena (CEIDP 2009), P81, DOI 10.1109/CEIDP.2009.5377744
[10]   Effect of humidity on the time to breakdown of polymers subject to partial discharges [J].
Guastavino, F ;
Tiemblo, P .
POLYMER ENGINEERING AND SCIENCE, 1998, 38 (01) :119-126