Adaptive non-parametric kernel density estimation for under-frequency load shedding with electric vehicles and renewable power uncertainty

被引:0
|
作者
Renhai, Feng [1 ]
Khan, Wajid [1 ]
Tariq, Afshan [1 ]
Abbas, Muhammad [1 ]
Yousaf, Muhammad Zain [2 ,3 ,4 ]
Aziz, Abdul [5 ]
Bajaj, Mohit [6 ,7 ,8 ]
Abdullah, Mustafa [9 ]
Tuka, Milkias [10 ]
机构
[1] Tianjin Univ, Sch Elect & Informat Engn, Tianjin 300072, Peoples R China
[2] Zhejiang Univ, Ctr Renewable Energy & Micro, Zhuji 311816, Zhejiang, Peoples R China
[3] Hubei Univ Automot Technol, Sch Elect & Informat Engn, Shiyan, Peoples R China
[4] Zhejiang Univ, Sch Aeronaut & Astronaut, Hangzhou 310027, Zhejiang, Peoples R China
[5] CECOS Univ IT & Emerging Sci, Peshawar, KPK, Pakistan
[6] Graph Era, Dept Elect Engn, Dehra Dun 248002, India
[7] Univ Business & Technol, Coll Engn, Jeddah 21448, Saudi Arabia
[8] Graph Era Hill Univ, Dehra Dun 248002, India
[9] Al Ahliyya Amman Univ, Fac Engn, Hourani Ctr Appl Sci Res, Elect vehicles Engn Dept, Amman, Jordan
[10] ASTU, Dept Elect & Comp Engn, Addis Ababa, Ethiopia
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Electric vehicle; Robust optimization; Under-frequency load shedding; Uncertainty Estimation; Wind power;
D O I
10.1038/s41598-025-94419-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
As power systems around the world shift to incorporate more renewable energy sources, particularly wind power, maintaining grid stability becomes increasingly challenging due to the inherent variability of these sources. This paper introduces a novel bi-level robust optimization framework that enhances the capabilities of adaptive Under-Frequency Load Shedding (AUFLS) in managing the uncertainties brought by high penetration of wind energy and dynamic participation of electric vehicles (EVs). Central to this framework is an innovative adaptive non-parametric Kernel Density Estimation (AAKDE) technique, which sharpens the accuracy of wind power fluctuation predictions. This method enables more precise and efficient control of load-shedding events, which is crucial for preventing frequency drops that can lead to grid instability. This research proposes a strategic shedding queue mechanism that systematically prioritizes the discharge of EVs based on their real-time state-of-charge and charging behavior. This prioritization minimizes user discomfort and taps into the potential of EVs as flexible energy resources, thus providing substantial support to grid operations. To enhance the responsiveness of our AUFLS approach, we integrate a reinforcement learning model that adjusts in real time to grid conditions, optimizing decision-making for frequency stabilization. Our extensive MATLAB/SIMULINK simulations on an upgraded IEEE 39 bus test system demonstrate a significant reduction in load shedding requirements. Compared to traditional AUFLS methods, our approach cuts load shedding by over 50%, effectively maintains system frequency within safe operational limits, and shows superior performance in scenarios of high renewable variability and EV integration. This research highlights the potential of adaptive non-parametric methods in transforming AUFLS strategies, paving the way for smarter, more resilient power systems equipped to handle the complexities of modern energy landscapes.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] Automatic Under-Frequency Load Shedding in New Zealand Power System-A Systematic Review
    Mollah, Kaium Uz Zaman
    Bahadornejad, Momen
    Nair, Nirmal K-C
    2011 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2011,
  • [42] A non-parametric approach for independent component analysis using kernel density estimation
    Sengupta, K
    Burman, P
    Sharma, R
    PROCEEDINGS OF THE 2004 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOL 2, 2004, : 667 - 672
  • [43] TRUS image segmentation with non-parametric kernel density estimation shape prior
    Wu, Pengfei
    Liu, Yiguang
    Li, Yongzhong
    Shi, Yongtao
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2013, 8 (06) : 764 - 771
  • [44] A non-parametric approach for independent component analysis using kernel density estimation
    Sengupta, Kuntal
    Burman, Prabir
    Sharma, Rajeev
    Proc IEEE Comput Soc Conf Comput Vision Pattern Recognit, 1600, (II667-II672):
  • [45] The influence of Motor low voltage trip on under-frequency load shedding in the Electric Network of Refinery Enterprise
    Han Tianzhen
    Yang Qi
    Song Yunting
    Tang Xiaojun
    Guo Qingkui
    THERMAL, POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 732-733 : 1119 - +
  • [46] Comparison of three Under-Frequency Load Shedding Schemes referring to the Power System of Sri Lanka
    Bambaravanage, Tharangika
    Kumarawadu, Sisil
    Rodrigo, Asanka
    ENGINEER-JOURNAL OF THE INSTITUTION OF ENGINEERS SRI LANKA, 2016, 49 (01): : 41 - 52
  • [47] Coordinated Scheme of Under-Frequency Load Shedding with Intelligent Appliances in a Cyber Physical Power System
    Wang, Qi
    Tang, Yi
    Li, Feng
    Li, Mengya
    Li, Yang
    Ni, Ming
    ENERGIES, 2016, 9 (08):
  • [48] An adaptive approach to non-parametric estimation of dynamic probability density functions
    Pana, Cristian
    Severi, Stefano
    de Abreu, Giuseppe Thadeu Freitas
    PROCEEDINGS OF THE 2016 13TH WORKSHOP ON POSITIONING, NAVIGATION AND COMMUNICATIONS (WPNC), 2016,
  • [49] Optimal design of an adaptive under-frequency load shedding scheme in smart grids considering operational uncertainties
    Rafinia, Ali
    Rezaei, Navid
    Moshtagh, Jamal
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 121
  • [50] Adaptive Under-Frequency Load-Shedding Considering Load Dynamics and Post Corrective Actions to Prevent Voltage Instability
    Horri, Ramin
    Roudsari, H. Mahdinia
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 185 (185)