External microwave applicators for hyperthermia therapy: a review

被引:0
作者
Singh, Soni [1 ]
Singh, Surya Pratap [2 ]
Singh, S. P. [3 ]
机构
[1] BRA Bihar Univ, Univ Dept Elect Sci, Muzaffarpur 842001, India
[2] Univ Oklahoma, Hlth Sci Ctr, Oklahoma City, OK 73104 USA
[3] Banaras Hindu Univ, Indian Inst Technol, Dept Elect Engn, Varanasi 221005, India
关键词
Non-invasive applicator; Hyperthermia; Microwave; Cancer; Antenna design; DIRECT-CONTACT APPLICATOR; QUALITY-ASSURANCE GUIDELINES; DIAGONAL HORN APPLICATORS; WATER BOLUS TEMPERATURE; LOADED LENS APPLICATOR; ANTENNA DESIGN; PATCH ANTENNA; LOCAL HYPERTHERMIA; SAR DISTRIBUTIONS; PHASED-ARRAYS;
D O I
10.1007/s42452-025-06621-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The continuous evolution of technology leads to increased application in health care. In recent years various efforts have been made in the treatment of cancer, including hyperthermia, but cancer remains a research subject worldwide. However, microwave hyperthermia has been an active area of research due to its advantages of focused heating of cancerous tissue while minimally affecting normal tissue. External hyperthermia applicators are designed and optimized to non-invasively couple microwave energy to the human body or other biological systems to kill cancerous cells and enhance the efficacy of radiation therapy and chemotherapy. These applicators need to meet various characteristics to make them suitable for the said applications, the most essential of which are applicator size, minimum leakage radiation, focused near field, and deep penetration. Many works are available in the literature for the hyperthermia applicator design, but none explores the large number of external applicators for hyperthermia treatment of cancer. This paper presents an extensive exploration of the development of external applicators (i.e., waveguide and planar) with a detailed investigation of the antenna element performance available for hyperthermia applications. This study attempts to identify the physiological and biological factors that affect the efficacy of efficient hyperthermia applicator design.
引用
收藏
页数:25
相关论文
共 144 条
  • [1] Amplitude analysis of B0? D0Ds+p - and B plus ? D -Ds plus p plus decays
    Aaij, R.
    Abdelmotteleb, A. S. W.
    Beteta, C. Abellan
    Abudinen, F.
    Ackernley, T.
    Adeva, B.
    Adinolfi, M.
    Afsharnia, H.
    Agapopoulou, C.
    Aidala, C. A.
    Aiola, S.
    Ajaltouni, Z.
    Akar, S.
    Akiba, K.
    Albrecht, J.
    Alessio, F.
    Alexander, M.
    Alfonso Albero, A.
    Aliouche, Z.
    Cartelle, P. Alvarez
    Amalric, R.
    Amato, S.
    Amey, J. L.
    Amhis, Y.
    An, L.
    Anderlini, L.
    Andersson, M.
    Andreianov, A.
    Andreotti, M.
    Andreou, D.
    Ao, D.
    Archilli, F.
    Artamonov, A.
    Artuso, M.
    Aslanides, E.
    Atzeni, M.
    Audurier, B.
    Bachmann, S.
    Bachmayer, M.
    Back, J. J.
    Bailly-reyre, A.
    Baladron Rodriguez, P.
    Balagura, V.
    Baldini, W.
    Baptista de Souza Leite, J.
    Barbetti, M.
    Barlow, R. J.
    Barsuk, S.
    Barter, W.
    Bartolini, M.
    [J]. PHYSICAL REVIEW D, 2023, 108 (01)
  • [2] FIELD ANALYSIS OF DIELECTRIC-LOADED LENS APPLICATOR FOR MICROWAVE HYPERTHERMIA
    ALEXANDER, PH
    LIU, JF
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1993, 41 (05) : 792 - 796
  • [3] HIGH PERMITTIVITY PATCH RADIATOR FOR SINGLE AND MULTIELEMENT HYPERTHERMIA APPLICATORS
    ANDREUCCETTI, D
    BINI, M
    IGNESTI, A
    OLMI, R
    PRIORI, S
    VANNI, R
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (07) : 711 - 715
  • [4] An ultra-wideband compact design for hyperthermia: Open ridged-waveguide antenna
    Aram, Morteza Ghaderi
    Aliakbarian, Hadi
    Trefna, Hana Dobsicek
    [J]. IET MICROWAVES ANTENNAS & PROPAGATION, 2022, 16 (2-3) : 137 - 152
  • [5] A phased array applicator based on open ridged-waveguide antenna for microwave hyperthermia
    Aram, Morteza Ghaderi
    Aliakbarian, Hadi
    Trefna, Hana Dobsicek
    [J]. MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2021, 63 (12) : 3086 - 3091
  • [6] FOCUSING OF 915 MHZ ELECTROMAGNETIC POWER ON DEEP HUMAN-TISSUES - A MATHEMATICAL-MODEL STUDY
    ARCANGELI, G
    LOMBARDINI, PP
    LOVISOLO, GA
    MARSIGLIA, G
    PIATTELLI, M
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (01) : 47 - 52
  • [7] Flexible Microwave Antenna Applicator for Chemo-Thermotherapy of the Breast
    Asili, Mustafa
    Chen, Pu
    Hood, Aaron Z.
    Purser, Anna
    Hulsey, Robert
    Johnson, Layne
    Ganesan, Adarsh Venkataraman
    Demirci, Utkan
    Topsakal, Erdem
    [J]. IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2015, 14 : 1778 - 1781
  • [8] NEW MICROSTRIP SLOT RADIATOR FOR MEDICAL APPLICATIONS
    BAHL, IJ
    STUCHLY, SS
    STUCHLY, MA
    [J]. ELECTRONICS LETTERS, 1980, 16 (19) : 731 - 732
  • [9] MICROSTRIP LOOP RADIATORS FOR MEDICAL APPLICATIONS
    BAHL, IJ
    STUCHLY, SS
    LAGENDIJK, JJW
    STUCHLY, MA
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1982, 30 (07) : 1090 - 1093
  • [10] A NEW MICROSTRIP RADIATOR FOR MEDICAL APPLICATIONS
    BAHL, IJ
    STUCHLY, SS
    STUCHLY, MA
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1980, 28 (12) : 1464 - 1468