Enhanced gait tracking measures for individuals with stroke using leg-worn inertial sensors

被引:0
|
作者
Lanotte, Francesco [1 ,2 ]
Okita, Shusuke [1 ,2 ]
O'Brien, Megan K. [1 ,2 ]
Jayaraman, Arun [1 ,2 ,3 ]
机构
[1] Max Nader Lab Rehabil Technol & Outcomes Res, Shirley Ryan AbilityLab, 355 E Erie St, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Phys Med & Rehabil, 710 N Lake Shore Dr, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Phys Therapy & Human Movement Sci, 710 N Lake Shore Dr, Chicago, IL 60611 USA
关键词
SPATIOTEMPORAL PARAMETERS; PARKINSONS-DISEASE; AMBULATORY SYSTEM; SYMMETRY;
D O I
10.1186/s12984-024-01521-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Clinical gait analysis plays a pivotal role in diagnosing and treating walking impairments. Inertial measurement units (IMUs) offer a low-cost, portable, and practical alternative to traditional gait analysis equipment, making these techniques more accessible beyond specialized clinics. Previous work and algorithms developed for specific clinical populations, like in individuals with Parkinson's disease, often do not translate effectively to other groups, such as stroke survivors, who exhibit significant variability in their gait patterns. The Salarian gait segmentation algorithm (SGSA) has demonstrated the potential to detect gait events and subsequently estimate clinical measures of gait speed, stride time, and other temporal parameters using two leg-worn IMUs in individuals with Parkinson's disease. However, the distinct gait impairments in stroke survivors, including hemiparesis, spasticity, and muscle weakness, can interfere with SGSA performance. Thus, the objective of this study was to develop and test an enhanced gait segmentation algorithm (EGSA) to capture temporal gait parameters in individuals with stroke. Methods Forty-one individuals with stroke were recruited from two acute rehabilitation settings and completed brief walking bouts with two leg-worn IMUs. We compared foot-off (FO), foot contact (FC), and temporal gait parameters computed from the SGSA and EGSA against ground truth measurements from an instrumented mat. Results The EGSA demonstrated greater accuracy than the SGSA when detecting gait events within one second, for both FO (96% vs. 90%) and FC (94% vs. 91%). The EGSA also demonstrated lower error than the SGSA when detecting paretic FC, and FO events in slow, asymmetrical, and non-paretic footfalls. Temporal gait parameters from the EGSA had high reliability (ICC > 0.90) for stride time, step time, stance time, and double support time across gait speeds and levels of asymmetry. Conclusion This approach has the potential to enhance the accuracy and validity of IMU-based gait analysis in individuals with stroke, thereby enhancing clinicians' ability to monitor and intervene for gait impairments in a rehabilitation setting and beyond.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Validation of shoe-worn Gait Up Physilog®5 wearable inertial sensors in adolescents
    Carroll, K.
    Kennedy, R. A.
    Koutoulas, V.
    Bui, M.
    Kraan, C. M.
    GAIT & POSTURE, 2022, 91 : 19 - 25
  • [22] Kinematic Gait Analysis Using Inertial Sensors with Subjects after Stroke in Two Different Arteries
    Mazuquin, Bruno Fles
    Batista Junior, Joao Pedro
    Pereira, Ligia Maxwell
    Dias, Josilainne Marcelino
    Silva, Mariana Felipe
    Carregaro, Rodrigo Luiz
    Garcia Lucareli, Paulo Roberto
    Moura, Felipe Arruda
    Cardoso, Jefferson Rosa
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2014, 26 (08) : 1307 - 1311
  • [23] Functional Gait Measures Prediction by Spatiotemporal and Gait Symmetry in Individuals Post Stroke
    Yonah Ofran
    Naama Karniel
    Jeanna Tsenter
    Isabella Schwartz
    Sigal Portnoy
    Journal of Developmental and Physical Disabilities, 2019, 31 : 611 - 622
  • [24] Functional Gait Measures Prediction by Spatiotemporal and Gait Symmetry in Individuals Post Stroke
    Ofran, Yonah
    Karniel, Naama
    Tsenter, Jeanna
    Schwartz, Isabella
    Portnoy, Sigal
    JOURNAL OF DEVELOPMENTAL AND PHYSICAL DISABILITIES, 2019, 31 (05) : 611 - 622
  • [25] Gait Analysis Using Floor Markers and Inertial Sensors
    Tri Nhut Do
    Suh, Young Soo
    SENSORS, 2012, 12 (02) : 1594 - 1611
  • [26] Gait Cycle Validation and Segmentation Using Inertial Sensors
    Prateek, G., V
    Mazzoni, Pietro
    Earhart, Gammon M.
    Nehorai, Arye
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (08) : 2132 - 2144
  • [27] Assessing the Impact of Fatigue on Gait Using Inertial Sensors
    Ameli, Sina
    Stirling, David
    Naghdy, Fazel
    Naghdy, Golshah
    Aghmesheh, Morteza
    2013 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM): MECHATRONICS FOR HUMAN WELLBEING, 2013, : 307 - 312
  • [28] Motor control complexity estimation using gait measures in individuals post-stroke
    Asadi, Azarang
    Higginson, Jill S.
    Reinbolt, Jeffrey A.
    JOURNAL OF BIOMECHANICS, 2025, 182
  • [29] Estimating fall risk with inertial sensors using gait stability measures that do not require step detection
    Riva, F.
    Toebes, M. J. P.
    Pijnappels, M.
    Stagni, R.
    van Dieen, J. H.
    GAIT & POSTURE, 2013, 38 (02) : 170 - 174
  • [30] Spatial-Temporal Analysis of Gait in Amyotrophic Lateral Sclerosis Using Foot-Worn Inertial Sensors: An Observational Study
    Lukac M.
    Luben H.
    Martin A.E.
    Simmons Z.
    Geronimo A.
    Digital Biomarkers, 2023, 8 (01) : 22 - 29