Enhanced gait tracking measures for individuals with stroke using leg-worn inertial sensors

被引:0
|
作者
Lanotte, Francesco [1 ,2 ]
Okita, Shusuke [1 ,2 ]
O'Brien, Megan K. [1 ,2 ]
Jayaraman, Arun [1 ,2 ,3 ]
机构
[1] Max Nader Lab Rehabil Technol & Outcomes Res, Shirley Ryan AbilityLab, 355 E Erie St, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Phys Med & Rehabil, 710 N Lake Shore Dr, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Phys Therapy & Human Movement Sci, 710 N Lake Shore Dr, Chicago, IL 60611 USA
关键词
SPATIOTEMPORAL PARAMETERS; PARKINSONS-DISEASE; AMBULATORY SYSTEM; SYMMETRY;
D O I
10.1186/s12984-024-01521-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Clinical gait analysis plays a pivotal role in diagnosing and treating walking impairments. Inertial measurement units (IMUs) offer a low-cost, portable, and practical alternative to traditional gait analysis equipment, making these techniques more accessible beyond specialized clinics. Previous work and algorithms developed for specific clinical populations, like in individuals with Parkinson's disease, often do not translate effectively to other groups, such as stroke survivors, who exhibit significant variability in their gait patterns. The Salarian gait segmentation algorithm (SGSA) has demonstrated the potential to detect gait events and subsequently estimate clinical measures of gait speed, stride time, and other temporal parameters using two leg-worn IMUs in individuals with Parkinson's disease. However, the distinct gait impairments in stroke survivors, including hemiparesis, spasticity, and muscle weakness, can interfere with SGSA performance. Thus, the objective of this study was to develop and test an enhanced gait segmentation algorithm (EGSA) to capture temporal gait parameters in individuals with stroke. Methods Forty-one individuals with stroke were recruited from two acute rehabilitation settings and completed brief walking bouts with two leg-worn IMUs. We compared foot-off (FO), foot contact (FC), and temporal gait parameters computed from the SGSA and EGSA against ground truth measurements from an instrumented mat. Results The EGSA demonstrated greater accuracy than the SGSA when detecting gait events within one second, for both FO (96% vs. 90%) and FC (94% vs. 91%). The EGSA also demonstrated lower error than the SGSA when detecting paretic FC, and FO events in slow, asymmetrical, and non-paretic footfalls. Temporal gait parameters from the EGSA had high reliability (ICC > 0.90) for stride time, step time, stance time, and double support time across gait speeds and levels of asymmetry. Conclusion This approach has the potential to enhance the accuracy and validity of IMU-based gait analysis in individuals with stroke, thereby enhancing clinicians' ability to monitor and intervene for gait impairments in a rehabilitation setting and beyond.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Validation of an algorithm to assess regular and irregular gait using inertial sensors in healthy and stroke individuals
    Ensink, Carmen
    Smulders, Katrijn
    Warnar, Jolien
    Keijsers, Noel
    PEERJ, 2023, 11
  • [2] Objective Measures of Ataxic Gait Using Wearable Inertial Sensors
    El-Gohary, M.
    Horak, L.
    Gomez, C.
    MOVEMENT DISORDERS, 2018, 33 : S292 - S292
  • [3] Gait and Axial Spondyloarthritis: Comparative Gait Analysis Study Using Foot-Worn Inertial Sensors
    Soulard, Julie
    Vaillant, Jacques
    Baillet, Athan
    Gaudin, Philippe
    Vuillerme, Nicolas
    JMIR MHEALTH AND UHEALTH, 2021, 9 (11):
  • [4] Human Gait Monitoring Using Body-Worn Inertial Sensors and Kinematic Modelling
    Ahmadi, Amin
    Destelle, Francois
    Monaghan, David
    Moran, Kieran
    O'Connor, Noel E.
    Unzueta, Luis
    Teresa Linaza, Maria
    2015 IEEE SENSORS, 2015, : 540 - 543
  • [5] Quaternion Based Gesture Recognition Using Worn Inertial Sensors in a Motion Tracking System
    Arsenault, Dennis L.
    Whitehead, Anthony D.
    2014 IEEE GAMES, MEDIA, ENTERTAINMENT (GEM), 2014,
  • [6] Modeling, Detecting, and Tracking Freezing of Gait in Parkinson Disease Using Inertial Sensors
    Prateek, G., V
    Skog, Isaac
    McNeely, Marie E.
    Duncan, Ryan P.
    Earhart, Gammon M.
    Nehorai, Arye
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (10) : 2152 - 2161
  • [7] Foot worn inertial sensors for gait assessment and rehabilitation based on motorized shoes
    Aminian, K.
    Mariani, B.
    Paraschiv-Ionescu, A.
    Hoskovec, C.
    Buela, C.
    Penders, J.
    Tacconi, C.
    Marcellini, F.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 5820 - 5823
  • [8] Calibration-Free Gait Assessment by Foot-Worn Inertial Sensors
    Laidig, Daniel
    Jocham, Andreas J.
    Guggenberger, Bernhard
    Adamer, Klemens
    Fischer, Michael
    Seel, Thomas
    FRONTIERS IN DIGITAL HEALTH, 2021, 3
  • [9] Activity Recognition using Head Worn Inertial Sensors
    Wolff, Johann P.
    Gruetzmacher, Florian
    Wellnitz, Arne
    Haubelt, Christian
    5TH INTERNATIONAL WORKSHOP ON SENSOR-BASED ACTIVITY RECOGNITION AND INTERACTION (IWOAR 2018), 2018,
  • [10] Using Body-Worn Sensors for Preliminary Rehabilitation Assessment in Stroke Victims With Gait Impairment
    Qiu, Sen
    Wang, Zhelong
    Zhao, Hongyu
    Liu, Long
    Jiang, Yongmei
    IEEE ACCESS, 2018, 6 : 31249 - 31258