AI-driven high-throughput droplet screening of cell-free gene expression

被引:0
|
作者
Zhu, Jiawei [1 ]
Meng, Yaru [1 ]
Gao, Wenli [1 ]
Yang, Shuo [1 ]
Zhu, Wenjie [1 ]
Ji, Xiangyang [1 ]
Zhai, Xuanpei [1 ]
Liu, Wan-Qiu [1 ]
Luo, Yuan [2 ]
Ling, Shengjie [1 ,3 ,4 ,5 ]
Li, Jian [1 ,3 ,4 ]
Liu, Yifan [1 ,3 ,4 ]
机构
[1] ShanghaiTech Univ, Sch Phys Sci & Technol, Shanghai, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Lab Transducer Technol, Shanghai, Peoples R China
[3] ShanghaiTech Univ, State Key Lab Adv Med Mat & Devices, Shanghai, Peoples R China
[4] Shanghai Clin Res & Trial Ctr, Shanghai, Peoples R China
[5] Fudan Univ, Dept Macromol Sci, State Key Lab Mol Engn Polymers, Lab Adv Mat, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
MICROFLUIDICS; OPTIMIZATION;
D O I
10.1038/s41467-025-58139-0
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Cell-free gene expression (CFE) systems enable transcription and translation using crude cellular extracts, offering a versatile platform for synthetic biology by eliminating the need to maintain living cells. However, Such systems are constrained by cumbersome composition, high costs, and limited yields due to numerous additional components required to maintain biocatalytic efficiency. Here, we introduce DropAI, a droplet-based, AI-driven screening strategy designed to optimize CFE systems with high throughput and economic efficiency. DropAI employs microfluidics to generate picoliter reactors and utilizes a fluorescent color-coding system to address and screen massive chemical combinations. The in-droplet screening is complemented by in silico optimization, where experimental results train a machine-learning model to estimate the contribution of the components and predict high-yield combinations. By applying DropAI, we significantly simplified the composition of an Escherichia coli-based CFE system, achieving a fourfold reduction in the unit cost of expressed superfolder green fluorescent protein (sfGFP). This optimized formulation was further validated across 12 different proteins. Notably, the established E. coli model is successfully adapted to a Bacillus subtilis-based system through transfer learning, leading to doubled yield through prediction. Beyond CFE, DropAI offers a high-throughput and scalable solution for combinatorial screening and optimization of biochemical systems.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Droplet-based microfluidics for high-throughput screening of a metagenomic library for isolation of microbial enzymes
    Hosokawa, Masahito
    Hoshino, Yuri
    Nishikawa, Yohei
    Hirose, Tomotada
    Yoon, Dong Hyun
    Mori, Tetsushi
    Sekiguchi, Tetsushi
    Shoji, Shuichi
    Takeyama, Haruko
    BIOSENSORS & BIOELECTRONICS, 2015, 67 : 379 - 385
  • [22] Robot Cookies - Plant Cell Packs as an Automated High-Throughput Screening Platform Based on Transient Expression
    Gengenbach, Benjamin Bruno
    Opdensteinen, Patrick
    Buyel, Johannes Felix
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2020, 8
  • [23] High-throughput screening for improved microbial cell factories, perspective and promise
    Leavell, Michael D.
    Singh, Amoolya H.
    Kaufmann-Malaga, Benjamin B.
    CURRENT OPINION IN BIOTECHNOLOGY, 2020, 62 (62) : 22 - 28
  • [24] Miniaturized microfluidic formats for cell-based high-throughput screening
    Upadhaya, Sarvesh
    Selvaganapathy, Ponnambalam Ravi
    Critical Reviews in Biomedical Engineering, 2009, 37 (03) : 193 - 257
  • [25] Linked optical and gene expression profiling of single cells at high-throughput
    Jesse Q. Zhang
    Christian A. Siltanen
    Leqian Liu
    Kai-Chun Chang
    Zev J. Gartner
    Adam R. Abate
    Genome Biology, 21
  • [26] Tackling Heterogeneity: A Leaf Disc-Based Assay for the High-Throughput Screening of Transient Gene Expression in Tobacco
    Piotrzkowski, Natalia
    Schillberg, Stefan
    Rasche, Stefan
    PLOS ONE, 2012, 7 (09):
  • [27] Linked optical and gene expression profiling of single cells at high-throughput
    Zhang, Jesse Q.
    Siltanen, Christian A.
    Liu, Leqian
    Chang, Kai-Chun
    Gartner, Zev J.
    Abate, Adam R.
    GENOME BIOLOGY, 2020, 21 (01)
  • [28] Mass Activated Droplet Sorting (MADS) Enables High-Throughput Screening of Enzymatic Reactions at Nanoliter Scale
    Holland-Moritz, Daniel A.
    Wismer, Michael K.
    Mann, Benjamin F.
    Farasat, Iman
    Devine, Paul
    Guetschow, Erik D.
    Mangion, Ian
    Welch, Christopher J.
    Moore, Jeffrey C.
    Sun, Shuwen
    Kennedy, Robert T.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2020, 59 (11) : 4470 - 4477
  • [29] Single-cell microliter-droplet screening system (MISS Cell): An integrated platform for automated high-throughput microbial monoclonal cultivation and picking
    Jian, Xingjin
    Guo, Xiaojie
    Cai, Zhengshuo
    Wei, Longfeng
    Wang, Liyan
    Xing, Xin-hui
    Zhang, Chong
    BIOTECHNOLOGY AND BIOENGINEERING, 2023, 120 (03) : 778 - 792
  • [30] Calibration-free quantification and automated data analysis for high-throughput reaction screening
    Katzenburg, Felix
    Boser, Florian
    Schaefer, Felix R.
    Pfluger, Philipp M.
    Glorius, Frank
    DIGITAL DISCOVERY, 2025, 4 (02): : 384 - 392