Does protruding headless cannulated screw reduce fixation stability in tension band wiring technique for patella fractures? a biomechanical study

被引:0
|
作者
Maden, Mehmet [1 ]
Bayraktar, Omer Berkay [2 ]
Bacaksiz, Tayfun [2 ]
Akan, Ihsan [2 ]
Uzun, Bora [3 ]
Kazimoglu, Cemal [2 ]
机构
[1] Ataturk Training & Res Hosp, Dept Orthopaed & Traumatol, Izmir, Turkiye
[2] Izmir Katip Celebi Univ, Dept Orthopaed & Traumatol, Izmir, Turkiye
[3] Dokuz Eylul Univ, Dept Biomech, Izmir, Turkiye
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2025年 / 20卷 / 01期
关键词
Patella fracture; Tension band wiring; Headless cannulated screw; Biomechanic; FIXED-ANGLE PLATE; INTERNAL-FIXATION; TRANSVERSE FRACTURES; NONUNION;
D O I
10.1186/s13018-025-05567-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe selection of an implant is a critical factor in the surgical treatment of patella fractures due to the risk of various complications, such as non-union, implant failure, and irritation. The present study evaluated and compared the biomechanical strength of headless cannulated screws about screw length using the tension band wiring technique.MethodsForty-eight sawbone patellas with transverse fractures were divided into three fixation groups based on the screw length used in tension band wiring. Overall, three different fixation groups were determined: Group 1 (recessed headless cannulated screw fixation), Group 2 (full-length headless cannulated screw fixation), and Group 3 (protruding headless cannulated screw fixation). A setup was used to simulate a knee with a flexion angle of 60 degrees. Specimens underwent biomechanical testing under axial traction (static test) and cyclic loading (dynamic test). Displacements at 300 Newtons (N), loads at 2 millimetres (mm) displacement, and failure loads were documented for each sample in the static test. In the dynamic test protocol, 10,000 repetitive cycles were performed under physiological load between 100 and 300 N, and final displacements were recorded.ResultsThere were significant differences in the loads achieved at 2 mm displacement levels, and Group 3 demonstrated lower force values compared to other constructs in the static test (P = 0.003). All groups revealed similar displacements at 300 N and failure load values under axial traction. In the dynamic test, Group 3 had significantly higher fracture displacement under cyclic loading compared to the other specimens (P = 0.006).ConclusionsThis study found headless cannulated screws for transverse patella fracture fixation provide sufficient stability; however, protruding headless screws reduce the fixation strength. Recessed or full-length screws may improve stability and bony healing, potentially preventing complications in patella fractures.Level of evidenceBiomechanical study N/A.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Intraprosthetic screw fixation increases primary fixation stability in periprosthetic fractures of the femur-A biomechanical study
    Brand, Stephan
    Klotz, Johannes
    Hassel, Thomas
    Petri, Maximilian
    Ettinger, Max
    Bach, Friedrich-Wilhelm
    Krettek, Christian
    Goesling, Thomas
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (02) : 239 - 243
  • [42] Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones
    Dominik Gruszka
    Charlotte Arand
    Julia Greenfield
    Tobias E. Nowak
    Raphael Kuechle
    Sebastian Kuhn
    Pol M. Rommens
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 1651 - 1658
  • [43] Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones
    Gruszka, Dominik
    Arand, Charlotte
    Greenfield, Julia
    Nowak, Tobias E.
    Kuechle, Raphael
    Kuhn, Sebastian
    Rommens, Pol M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (12) : 1651 - 1658
  • [44] A Comparative Study of Functional Outcome of Olecranon Fractures Managed with Tension band Wiring Using K Wires with Tension Band Wiring Using Cancellous Screws Fixation
    Parate, Ashutosh
    Gawande, Vasant
    Gupta, Suvarn
    Jaiwal, Ankit
    Chavan, Ashwin
    Saoji, Kunal
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (37A) : 193 - 198
  • [45] The effect of ding's screw and tension band wiring for treatment of olecranon fractures: a finite element study
    Yin, Nuo
    Pan, Mingmang
    Li, Chenglei
    Du, Li
    Ding, Liang
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [46] The effect of ding’s screw and tension band wiring for treatment of olecranon fractures: a finite element study
    Nuo Yin
    Mingmang Pan
    Chenglei Li
    Li Du
    Liang Ding
    BMC Musculoskeletal Disorders, 24
  • [47] Cyclic long-term loading of a bilateral fixed-angle plate in comparison with tension band wiring with K-wires or cannulated screws in transverse patella fractures
    Thelen, Simon
    Schneppendahl, Johannes
    Baumgaertner, Ralf
    Eichler, Christian
    Koebke, Juergen
    Betsch, Marcel
    Hakimi, Mohssen
    Windolf, Joachim
    Wild, Michael
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (02) : 311 - 317
  • [48] A Randomized Comparative Study of Functional and Radiological Outcome of Tension Band Wiring for Patella Fractures Using SS Wire Versus Fiberwire
    P. T. Noothan
    S. A. Somashekara
    S. R. Sunkappa
    B. Karthik
    K. Rameshkrishnan
    Indian Journal of Orthopaedics, 2023, 57 : 876 - 883
  • [50] Cyclic long-term loading of a bilateral fixed-angle plate in comparison with tension band wiring with K-wires or cannulated screws in transverse patella fractures
    Simon Thelen
    Johannes Schneppendahl
    Ralf Baumgärtner
    Christian Eichler
    Jürgen Koebke
    Marcel Betsch
    Mohssen Hakimi
    Joachim Windolf
    Michael Wild
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 311 - 317