Does protruding headless cannulated screw reduce fixation stability in tension band wiring technique for patella fractures? a biomechanical study

被引:0
|
作者
Maden, Mehmet [1 ]
Bayraktar, Omer Berkay [2 ]
Bacaksiz, Tayfun [2 ]
Akan, Ihsan [2 ]
Uzun, Bora [3 ]
Kazimoglu, Cemal [2 ]
机构
[1] Ataturk Training & Res Hosp, Dept Orthopaed & Traumatol, Izmir, Turkiye
[2] Izmir Katip Celebi Univ, Dept Orthopaed & Traumatol, Izmir, Turkiye
[3] Dokuz Eylul Univ, Dept Biomech, Izmir, Turkiye
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2025年 / 20卷 / 01期
关键词
Patella fracture; Tension band wiring; Headless cannulated screw; Biomechanic; FIXED-ANGLE PLATE; INTERNAL-FIXATION; TRANSVERSE FRACTURES; NONUNION;
D O I
10.1186/s13018-025-05567-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe selection of an implant is a critical factor in the surgical treatment of patella fractures due to the risk of various complications, such as non-union, implant failure, and irritation. The present study evaluated and compared the biomechanical strength of headless cannulated screws about screw length using the tension band wiring technique.MethodsForty-eight sawbone patellas with transverse fractures were divided into three fixation groups based on the screw length used in tension band wiring. Overall, three different fixation groups were determined: Group 1 (recessed headless cannulated screw fixation), Group 2 (full-length headless cannulated screw fixation), and Group 3 (protruding headless cannulated screw fixation). A setup was used to simulate a knee with a flexion angle of 60 degrees. Specimens underwent biomechanical testing under axial traction (static test) and cyclic loading (dynamic test). Displacements at 300 Newtons (N), loads at 2 millimetres (mm) displacement, and failure loads were documented for each sample in the static test. In the dynamic test protocol, 10,000 repetitive cycles were performed under physiological load between 100 and 300 N, and final displacements were recorded.ResultsThere were significant differences in the loads achieved at 2 mm displacement levels, and Group 3 demonstrated lower force values compared to other constructs in the static test (P = 0.003). All groups revealed similar displacements at 300 N and failure load values under axial traction. In the dynamic test, Group 3 had significantly higher fracture displacement under cyclic loading compared to the other specimens (P = 0.006).ConclusionsThis study found headless cannulated screws for transverse patella fracture fixation provide sufficient stability; however, protruding headless screws reduce the fixation strength. Recessed or full-length screws may improve stability and bony healing, potentially preventing complications in patella fractures.Level of evidenceBiomechanical study N/A.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Biomechanical comparison of a 3.5 mm anterior locking plate to cannulated screws with anterior tension band wiring in comminuted patellar fractures
    Wagner, Ferdinand C.
    Neumann, Mirjam, V
    Wolf, Steffen
    Jonaszik, Alexander
    Izadpanah, Kaywan
    Piatek, Stefan
    Suedkamp, Norbert P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (06): : 1281 - 1287
  • [32] Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation
    Zderic, Ivan
    Stoffel, Karl
    Sommer, Christoph
    Hoentzsch, Dankward
    Gueorguiev, Boyko
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (08): : 1749 - 1757
  • [33] Anterior variable-angle locked plating versus tension band wiring of simple and complex patella fractures - a biomechanical investigation
    Stoffel, Karl
    Zderic, Ivan
    Pastor, Torsten
    Woodburn, William
    Castle, Richard
    Penman, Jessica
    Saura-Sanchez, Eladio
    Gueorguiev, Boyko
    Sommer, Christoph
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [34] Anterior variable-angle locked plating versus tension band wiring of simple and complex patella fractures – a biomechanical investigation
    Karl Stoffel
    Ivan Zderic
    Torsten Pastor
    William Woodburn
    Richard Castle
    Jessica Penman
    Eladio Saura-Sanchez
    Boyko Gueorguiev
    Christoph Sommer
    BMC Musculoskeletal Disorders, 24
  • [35] The effect of Ding's screws and tension band wiring for treatment of olecranon fractures: a biomechanical study
    Zhao, Yong
    Tian, Hongbo
    Yin, Nuo
    Du, Li
    Pan, Mingmang
    Ding, Liang
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [36] INTERNAL-FIXATION OF PROXIMAL HUMERUS FRACTURES USING THE SCREW-TENSION BAND TECHNIQUE
    CORNELL, CN
    LEVINE, D
    PAGNANI, MJ
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1994, 8 (01) : 23 - 27
  • [37] Tension band wiring versus screw fixation for the treatment of medial malleolar fractures: A systematic review and meta-analysis
    Kim, Chul-Ho
    Ma, Dae Sung
    Yoon, Yong-Cheol
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2023, 109 (05)
  • [38] A Randomized Comparative Study of Functional and Radiological Outcome of Tension Band Wiring for Patella Fractures Using SS Wire Versus Fiberwire
    Noothan, P. T.
    Somashekara, S. A.
    Sunkappa, S. R.
    Karthik, B.
    Rameshkrishnan, K.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2023, 57 (06) : 876 - 883
  • [39] Titanium mesh as a low-profile alternative for tension-band augmentation in patella fracture fixation: A biomechanical study
    Dickens, Aaron J.
    Salas, Christina
    Rise, LeRoy
    Murray-Krezan, Cristina
    Taha, Mahmoud Reda
    DeCoster, Thomas A.
    Gehlert, Rick J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (06): : 1001 - 1006
  • [40] Comparison of the outcomes of cannulated screws vs. modified tension band wiring fixation techniques in the management of mildly displaced patellar fractures
    Lin, Tao
    Liu, Junbin
    Xiao, Baojun
    Fu, Dehao
    Yang, Shuhua
    BMC MUSCULOSKELETAL DISORDERS, 2015, 16