Does protruding headless cannulated screw reduce fixation stability in tension band wiring technique for patella fractures? a biomechanical study

被引:0
|
作者
Maden, Mehmet [1 ]
Bayraktar, Omer Berkay [2 ]
Bacaksiz, Tayfun [2 ]
Akan, Ihsan [2 ]
Uzun, Bora [3 ]
Kazimoglu, Cemal [2 ]
机构
[1] Ataturk Training & Res Hosp, Dept Orthopaed & Traumatol, Izmir, Turkiye
[2] Izmir Katip Celebi Univ, Dept Orthopaed & Traumatol, Izmir, Turkiye
[3] Dokuz Eylul Univ, Dept Biomech, Izmir, Turkiye
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2025年 / 20卷 / 01期
关键词
Patella fracture; Tension band wiring; Headless cannulated screw; Biomechanic; FIXED-ANGLE PLATE; INTERNAL-FIXATION; TRANSVERSE FRACTURES; NONUNION;
D O I
10.1186/s13018-025-05567-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe selection of an implant is a critical factor in the surgical treatment of patella fractures due to the risk of various complications, such as non-union, implant failure, and irritation. The present study evaluated and compared the biomechanical strength of headless cannulated screws about screw length using the tension band wiring technique.MethodsForty-eight sawbone patellas with transverse fractures were divided into three fixation groups based on the screw length used in tension band wiring. Overall, three different fixation groups were determined: Group 1 (recessed headless cannulated screw fixation), Group 2 (full-length headless cannulated screw fixation), and Group 3 (protruding headless cannulated screw fixation). A setup was used to simulate a knee with a flexion angle of 60 degrees. Specimens underwent biomechanical testing under axial traction (static test) and cyclic loading (dynamic test). Displacements at 300 Newtons (N), loads at 2 millimetres (mm) displacement, and failure loads were documented for each sample in the static test. In the dynamic test protocol, 10,000 repetitive cycles were performed under physiological load between 100 and 300 N, and final displacements were recorded.ResultsThere were significant differences in the loads achieved at 2 mm displacement levels, and Group 3 demonstrated lower force values compared to other constructs in the static test (P = 0.003). All groups revealed similar displacements at 300 N and failure load values under axial traction. In the dynamic test, Group 3 had significantly higher fracture displacement under cyclic loading compared to the other specimens (P = 0.006).ConclusionsThis study found headless cannulated screws for transverse patella fracture fixation provide sufficient stability; however, protruding headless screws reduce the fixation strength. Recessed or full-length screws may improve stability and bony healing, potentially preventing complications in patella fractures.Level of evidenceBiomechanical study N/A.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Tension band wiring through double-cannulated screws as a new internal fixation method for treatment of olecranon fractures: a randomized comparative study
    Lu, Qi-feng
    Tang, Gen-ling
    Zhao, Xi-jiang
    Zhang, Wen-jie
    Guo, Shu-guang
    Wang, Hang-zhou
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2015, 49 (06) : 654 - 660
  • [22] Olecranon fractures: A biomechanical comparison of three tension band wiring fixation methods on bone models
    Calisal, Emre
    Ugur, Levent
    JOURNAL OF ORTHOPAEDIC SURGERY, 2023, 31 (03)
  • [23] Biomechanical comparison of tension band wiring and plate fixation with locking screws in transverse olecranon fractures
    Midtgaard, Kaare Sourin
    Soreide, Endre
    Brattgjerd, Jan Egil
    Moatshe, Gilbert
    Madsen, Jan Erik
    Flugsrud, Gunnar B.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (06) : 1242 - 1248
  • [24] Transverse patella fracture fixation: A cadaveric biomechanical comparison of cannulated screws and anterior tension band versus low-profile, multiplanar mesh plating
    Garner, Matthew R.
    Homcha, Brittany
    Cowman, Trevin
    Goss, Madison
    Reid, J. Spence
    Lewis, Gregory S.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (06):
  • [25] Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study
    Stephen Warner
    Christoph Sommer
    Ivan Zderic
    William Woodburn
    Richard Castle
    Jessica Penman
    Eladio Saura-Sanchez
    David L. Helfet
    Boyko Gueorguiev
    Karl Stoffel
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 2131 - 2140
  • [26] Does pin configuration matter in modified tension band wiring for transverse patellar fracture? A biomechanical study
    Maden, Mehmet
    Dulgeroglu, Ali Murat
    Bacaksiz, Tayfun
    Kazimoglu, Cemal
    KNEE, 2022, 39 : 300 - 307
  • [27] Cannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study
    Gardner, A. W.
    Toh, M. Z.
    Yew, K. S. A.
    Lie, D. T. T.
    Chou, S. M.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (01) : 41 - 46
  • [28] Fixation of Transverse Olecranon Fractures by Suture Bridge Method Using Suture Anchor: Biomechanical Comparison with Tension Band Wiring Technique
    Lee, Hyun Il
    Cho, Jin Ho
    Choi, Jun Young
    Lee, Sung Sahn
    Cho, Sung Tan
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2021, 26 (04) : 563 - 570
  • [29] Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study
    Warner, Stephen
    Sommer, Christoph
    Zderic, Ivan
    Woodburn, William
    Castle, Richard
    Penman, Jessica
    Saura-Sanchez, Eladio
    Helfet, David L.
    Gueorguiev, Boyko
    Stoffel, Karl
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (05) : 2131 - 2140
  • [30] Treatment of displaced fractures of the patella: Tension band wiring technique with the one-end or both-ends K-wire bending fixation method
    Huang, Po-Hua
    Hsu, Chi-Hsiang
    Hsu, Shan-Ling
    Liu, Hao-Chen
    JOURNAL OF ORTHOPAEDIC SURGERY, 2021, 29 (01)