Does protruding headless cannulated screw reduce fixation stability in tension band wiring technique for patella fractures? a biomechanical study

被引:0
|
作者
Maden, Mehmet [1 ]
Bayraktar, Omer Berkay [2 ]
Bacaksiz, Tayfun [2 ]
Akan, Ihsan [2 ]
Uzun, Bora [3 ]
Kazimoglu, Cemal [2 ]
机构
[1] Ataturk Training & Res Hosp, Dept Orthopaed & Traumatol, Izmir, Turkiye
[2] Izmir Katip Celebi Univ, Dept Orthopaed & Traumatol, Izmir, Turkiye
[3] Dokuz Eylul Univ, Dept Biomech, Izmir, Turkiye
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2025年 / 20卷 / 01期
关键词
Patella fracture; Tension band wiring; Headless cannulated screw; Biomechanic; FIXED-ANGLE PLATE; INTERNAL-FIXATION; TRANSVERSE FRACTURES; NONUNION;
D O I
10.1186/s13018-025-05567-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe selection of an implant is a critical factor in the surgical treatment of patella fractures due to the risk of various complications, such as non-union, implant failure, and irritation. The present study evaluated and compared the biomechanical strength of headless cannulated screws about screw length using the tension band wiring technique.MethodsForty-eight sawbone patellas with transverse fractures were divided into three fixation groups based on the screw length used in tension band wiring. Overall, three different fixation groups were determined: Group 1 (recessed headless cannulated screw fixation), Group 2 (full-length headless cannulated screw fixation), and Group 3 (protruding headless cannulated screw fixation). A setup was used to simulate a knee with a flexion angle of 60 degrees. Specimens underwent biomechanical testing under axial traction (static test) and cyclic loading (dynamic test). Displacements at 300 Newtons (N), loads at 2 millimetres (mm) displacement, and failure loads were documented for each sample in the static test. In the dynamic test protocol, 10,000 repetitive cycles were performed under physiological load between 100 and 300 N, and final displacements were recorded.ResultsThere were significant differences in the loads achieved at 2 mm displacement levels, and Group 3 demonstrated lower force values compared to other constructs in the static test (P = 0.003). All groups revealed similar displacements at 300 N and failure load values under axial traction. In the dynamic test, Group 3 had significantly higher fracture displacement under cyclic loading compared to the other specimens (P = 0.006).ConclusionsThis study found headless cannulated screws for transverse patella fracture fixation provide sufficient stability; however, protruding headless screws reduce the fixation strength. Recessed or full-length screws may improve stability and bony healing, potentially preventing complications in patella fractures.Level of evidenceBiomechanical study N/A.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Treatment of longitudinal fractures of patella by percutaneous cannulated screws with tension band wiring technique
    Cheng, Anyuan
    Xu, Fusheng
    Huang, Zifeng
    Xu, Li
    Shi, Chen
    Zhang, Wei
    Song, Qi
    MINERVA ORTHOPEDICS, 2021, 72 (04): : 407 - 411
  • [2] Comparison of Cannulated Screw With Tension Band Wiring Versus Compressive Cannulated Locking Bolt and Nut Device (CompresSURE) in Patella Fractures-A Cadaveric Biomechanical Study
    Domby, Brian
    Henderson, Eric
    Nayak, Aniruddh
    Erdogan, Murat
    Gutierrez, Sergio
    Santoni, Brandon G.
    Sagi, H. Claude
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (12) : 678 - 683
  • [3] Cannulated compression screws with cable technique leads to a dramatic reduction in patella fracture fixation complications compared to tension band wiring
    Poh, Jane Wenjin
    Li, Zongxian
    Koh, Don Thong Siang
    Tay, Kenny Xian Khing
    Goh, Seo Kiat
    Woo, Yew Lok
    Xia, Zhan
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (09) : 4333 - 4341
  • [4] Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation in transverse patella fractures
    Thelen, Simon
    Schneppendahl, Johannes
    Jopen, Eva
    Eichler, Christian
    Koebke, Juergen
    Schoenau, Eckhard
    Hakimi, Mohssen
    Windolf, Joachim
    Wild, Michael
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (08): : 1290 - 1295
  • [5] Biomechanical Comparison of Tension Band Fixation of Patella Transverse Fracture: Headless Screws Versus Headed Screws
    Martin, Jill M.
    Applin, Dylan T.
    McGrady, Linda M.
    Wang, Mei
    Schmeling, Gregory J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (06) : E240 - E245
  • [6] Comparative study of locking neutralization plate construct versus tension band wiring with a cannulated screw for patella fractures: experimental and finite element analysis
    Kim, Sunjung
    Mungalpara, Nirav
    Wangikar, Rohan
    Tarabichi, Majd
    Karam, Joseph
    Bedi, Asheesh
    Koh, Jason
    Amirouche, Farid
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01)
  • [7] Biomechanical analysis of tension band wiring (TBW) of transverse fractures of patella
    Ali, Mohammed
    Kuiper, Jan
    John, Joby
    CHINESE JOURNAL OF TRAUMATOLOGY, 2016, 19 (05) : 255 - 258
  • [8] Suture tension band fixation vs. metallic tension band wiring for patella fractures - A biomechanical study on 19 human cadaveric patellae
    Adjal, Jonas
    Haugaard, Asger
    Vesterby, Liv
    Ibrahim, Huda Muhudin
    Sert, Kevser
    Thomsen, Morten Grove
    Tengberg, Peter Toft
    Ban, Ilija
    Ohrt-Nissen, Soren
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (08): : 2749 - 2753
  • [9] Biomechanical analysis of tension band wiring (TBW) of transverse fractures of patella
    Ali Mohammed
    Kuiper Jan
    John Joby
    中华创伤杂志英文版, 2016, 19 (05) : 255 - 258
  • [10] Biomechanical comparison of tension band suture fixation and tension band wiring in olecranon fractures
    Vesterby, Liv
    Haugaard, Asger Martin
    Adjal, Jonas
    Muhudin, Huda Ibrahim
    Sert, Kevser
    Thomsen, Morten Grove
    Ban, Ilija
    Ohrt-Nissen, Soren
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (08):