Impact of molten salt inflow on the temperature distribution in thermal energy storage tanks at startup for central receiver concentrating solar power plants

被引:0
作者
Torres-Madronero, Jose L. [1 ,2 ]
Osorio, Julian D. [3 ]
Nieto-Londono, Cesar [1 ]
Ordonez, Juan C. [2 ]
机构
[1] Univ Pontificia Bolivariana, Escuela Ingn, Grp Energia & Termodinam, Medellin 050031, Colombia
[2] Florida State Univ, Ctr Adv Power Syst, Dept Mech Engn, Tallahassee, FL 32310 USA
[3] Natl Renewable Energy Lab, Ctr Energy Convers & Storage, Golden, CO 80401 USA
关键词
Thermal energy storage; Concentrating solar power; Molten salt storage tank; Sparger ring design; Temperature gradients; Startup operation conditions;
D O I
10.1016/j.est.2025.116069
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Concentrating Solar Power (CSP) systems with molten salt thermal energy storage (TES) tanks are one of the most promising, renewable-based energy conversion technologies for larger-scale power generation. The TES tank is one of the most critical components in CSP plants due to its high-temperature operation (up to 565 degrees C), daily thermal cycling, and intermittent solar radiation conditions. The plant startup is one of the most challenging operation conditions that could lead to damaging thermal gradients due to low salt inventory levels. In this study an analytical model for the sparger ring was developed and integrated with a detailed computational fluid dynamics model of a commercial-scaled molten salt tank. The integrated model allows an accurate representation of the tank operation to evaluate the effect of molten salt inflow on the mixing process. The tank filling process during plant startup was analyzed considering sparger rings with variations in design features, including inlet orifice configurations, number of orifices, direction of the inlets, and orifice diameter. The results demonstrated that higher temperature gradients are obtained in the tank floor during the plant startup. A sparger ring configuration with a predetermined orifice inlet inclination (30 degrees, 45 degrees and 60 degrees) leads to significant temperature differences in the floor, between 57 degrees C and 62 degrees C, but better homogeneity in the temperature of the salt inventory. Lower salt inflow velocities result in a more homogeneous floor temperature, with maximum temperature differences under 38 degrees C. The sparger ring configuration with 52 orifices of 1-in. diameter and vertical flow showed better homogeneity in the temperature differences as a function of the salt level and lower temperature gradients in the tank floor. Because large temperature gradients in the tank's floor have been identified as one of the main factors contributing to tank failures, assessing various sparger ring design features is fundamental to determining proper inflow conditions that lead to low-temperature gradients and reducing failure susceptibility.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Impact of Solar Salt aging on corrosion of martensitic and austenitic steel for concentrating solar power plants
    Bonk, Alexander
    Rueckle, Dagmar
    Kaesche, Stefanie
    Braun, Markus
    Bauer, Thomas
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2019, 203
  • [22] Molten salt corrosion mechanisms of nitrate based thermal energy storage materials for concentrated solar power plants: A review
    Fernandez, Angel G.
    Cabeza, Luisa F.
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2019, 194 : 160 - 165
  • [23] A Novel Modeling of Molten-Salt Heat Storage Systems in Thermal Solar Power Plants
    Peon Menendez, Rogelio
    Martinez, Juan A.
    Prieto, Miguel J.
    Barcia, Lourdes A.
    Martin Sanchez, Juan M.
    [J]. ENERGIES, 2014, 7 (10): : 6721 - 6740
  • [24] Development of solid particle thermal energy storage for concentrating solar power plants that use fluidized bed technology
    Ma, Z.
    Glatzmaier, G. C.
    Mehos, M.
    [J]. PROCEEDINGS OF THE SOLARPACES 2013 INTERNATIONAL CONFERENCE, 2014, 49 : 898 - 907
  • [25] A Review of High-Temperature Molten Salt for Third-Generation Concentrating Solar Power
    Liu, Xu
    Zhong, Yuan
    Li, Jinli
    Wang, Huaiyou
    Wang, Min
    [J]. ENERGY SCIENCE & ENGINEERING, 2025, 13 (02) : 456 - 474
  • [26] Techno-Economic Optimization of Molten Salt Concentrating Solar Power Parabolic Trough Plants With Packed-Bed Thermocline Tanks
    Klasing, Freerk
    Hirsch, Tobias
    Odenthal, Christian
    Bauer, Thomas
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (05):
  • [27] Metal hydrides for concentrating solar thermal power energy storage
    D. A. Sheppard
    M. Paskevicius
    T. D. Humphries
    M. Felderhoff
    G. Capurso
    J. Bellosta von Colbe
    M. Dornheim
    T. Klassen
    P. A. Ward
    J. A. Teprovich
    C. Corgnale
    R. Zidan
    D. M. Grant
    C. E. Buckley
    [J]. Applied Physics A, 2016, 122
  • [28] Economic Optimization of a Concentrating Solar Power Plant With Molten-Salt Thermocline Storage
    Flueckiger, Scott M.
    Iverson, Brian D.
    Garimella, Suresh V.
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (01):
  • [29] How Thermal Energy Storage Enhances the Economic Viability of Concentrating Solar Power
    Madaeni, Seyed Hossein
    Sioshansi, Ramteen
    Denholm, Paul
    [J]. PROCEEDINGS OF THE IEEE, 2012, 100 (02) : 335 - 347
  • [30] Techno-economic performance of the solar tower power plants integrating with 650 °C high-temperature molten salt thermal energy storage
    Chen, Xinyu
    Wang, Liang
    Li, Xiaojun
    Ji, Jianzhou
    Lin, Xipeng
    Zhang, Hualiang
    Liu, Feng
    Chen, Haisheng
    [J]. ENERGY, 2025, 324