Impact of molten salt inflow on the temperature distribution in thermal energy storage tanks at startup for central receiver concentrating solar power plants

被引:0
|
作者
Torres-Madronero, Jose L. [1 ,2 ]
Osorio, Julian D. [3 ]
Nieto-Londono, Cesar [1 ]
Ordonez, Juan C. [2 ]
机构
[1] Univ Pontificia Bolivariana, Escuela Ingn, Grp Energia & Termodinam, Medellin 050031, Colombia
[2] Florida State Univ, Ctr Adv Power Syst, Dept Mech Engn, Tallahassee, FL 32310 USA
[3] Natl Renewable Energy Lab, Ctr Energy Convers & Storage, Golden, CO 80401 USA
关键词
Thermal energy storage; Concentrating solar power; Molten salt storage tank; Sparger ring design; Temperature gradients; Startup operation conditions;
D O I
10.1016/j.est.2025.116069
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Concentrating Solar Power (CSP) systems with molten salt thermal energy storage (TES) tanks are one of the most promising, renewable-based energy conversion technologies for larger-scale power generation. The TES tank is one of the most critical components in CSP plants due to its high-temperature operation (up to 565 degrees C), daily thermal cycling, and intermittent solar radiation conditions. The plant startup is one of the most challenging operation conditions that could lead to damaging thermal gradients due to low salt inventory levels. In this study an analytical model for the sparger ring was developed and integrated with a detailed computational fluid dynamics model of a commercial-scaled molten salt tank. The integrated model allows an accurate representation of the tank operation to evaluate the effect of molten salt inflow on the mixing process. The tank filling process during plant startup was analyzed considering sparger rings with variations in design features, including inlet orifice configurations, number of orifices, direction of the inlets, and orifice diameter. The results demonstrated that higher temperature gradients are obtained in the tank floor during the plant startup. A sparger ring configuration with a predetermined orifice inlet inclination (30 degrees, 45 degrees and 60 degrees) leads to significant temperature differences in the floor, between 57 degrees C and 62 degrees C, but better homogeneity in the temperature of the salt inventory. Lower salt inflow velocities result in a more homogeneous floor temperature, with maximum temperature differences under 38 degrees C. The sparger ring configuration with 52 orifices of 1-in. diameter and vertical flow showed better homogeneity in the temperature differences as a function of the salt level and lower temperature gradients in the tank floor. Because large temperature gradients in the tank's floor have been identified as one of the main factors contributing to tank failures, assessing various sparger ring design features is fundamental to determining proper inflow conditions that lead to low-temperature gradients and reducing failure susceptibility.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] An experimental investigation of temperature distribution and heat loss in molten salt tanks in concentrating solar power plants
    Zhou, Hao
    Shi, Hua
    Zhu, Yifan
    Fang, Wenfeng
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2020, 12 (01)
  • [2] Corrosion mechanisms in molten salt thermal energy storage for concentrating solar power
    Bell, S.
    Steinberg, T.
    Will, G.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2019, 114
  • [3] Effect of operating parameters on thermal performance of molten salt packed-bed thermocline thermal energy storage system for concentrating solar power plants
    Abdulla, Ajas
    Reddy, K. S.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2017, 121 : 30 - 44
  • [4] Thermal stability of granite for high temperature thermal energy storage in concentrating solar power plants
    Li, Baiyi
    Ju, Feng
    APPLIED THERMAL ENGINEERING, 2018, 138 : 409 - 416
  • [5] Evaluation of annual efficiencies of high temperature central receiver concentrated solar power plants with thermal energy storage
    Ehrhart, B.
    Gill, D.
    PROCEEDINGS OF THE SOLARPACES 2013 INTERNATIONAL CONFERENCE, 2014, 49 : 752 - 761
  • [6] Cyclic thermal characterization of a molten-salt packed-bed thermal energy storage for concentrating solar power
    Zhao, Bing-chen
    Cheng, Mao-song
    Liu, Chang
    Dai, Zhi-min
    APPLIED ENERGY, 2017, 195 : 761 - 773
  • [7] LCOE Analysis of Tower Concentrating Solar Power Plants Using Different Molten-Salts for Thermal Energy Storage in China
    Zhuang, Xiaoru
    Xu, Xinhai
    Liu, Wenrui
    Xu, Wenfu
    ENERGIES, 2019, 12 (07)
  • [8] System-level performance optimization of molten-salt packed-bed thermal energy storage for concentrating solar power
    Zhao, Bing-chen
    Cheng, Mao-song
    Liu, Chang
    Dai, Zhi-min
    APPLIED ENERGY, 2018, 226 : 225 - 239
  • [9] Optimization of thermal energy storage integration strategies for peak power production by concentrating solar power plants
    Guedez, R.
    Spelling, J.
    Laumert, B.
    Fransson, T.
    PROCEEDINGS OF THE SOLARPACES 2013 INTERNATIONAL CONFERENCE, 2014, 49 : 1642 - 1651
  • [10] Mixing enhancement in thermal energy storage molten salt tanks
    Iranzo, Alfredo
    Suarez, Christian
    Guerra, Jose