Deep-learning-based attenuation map generation in kidney single photon emission computed tomography

被引:0
|
作者
Kwon, Kyounghyoun [1 ,2 ]
Oh, Dongkyu [2 ,3 ]
Kim, Ji Hye [2 ]
Yoo, Jihyung [2 ]
Lee, Won Woo [1 ,2 ,3 ,4 ]
机构
[1] Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Dept Hlth Sci & Technol, Gwanggyo Ro 145, Suwon 16229, South Korea
[2] Seoul Natl Univ, Dept Nucl Med, Coll Med, Bundang Hosp, 82 Gumi Ro,173 Beon Gil,Gyeonggi Do, Seongnam 13620, South Korea
[3] Seoul Natl Univ, Coll Med, Dept Nucl Med, 103 Daehak Ro, Seoul 03080, South Korea
[4] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, 101 Daehak Ro, Seoul 03080, South Korea
来源
EJNMMI PHYSICS | 2024年 / 11卷 / 01期
基金
新加坡国家研究基金会;
关键词
Attenuation correction; Deep learning; SPECT/CT; Kidney imaging; Quantitative imaging; GLOMERULAR-FILTRATION-RATE; NEURAL-NETWORK; TC-99M DTPA;
D O I
10.1186/s40658-024-00686-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Accurate attenuation correction (AC) is vital in nuclear medicine, particularly for quantitative single-photon emission computed tomography/computed tomography (SPECT/CT) imaging. This study aimed to establish a CT-free quantification technology in kidney SPECT imaging using deep learning to generate synthetic attenuation maps (mu-maps) from SPECT data, thereby reducing radiation exposure and eliminating the need for CT scans. Results A dataset of 1000 Tc-99m DTPA SPECT/CT scans was analyzed for training (n = 800), validation (n = 100), and testing (n = 100) using a modified 3D U-Net for deep learning. The study investigated the use of primary emission and scattering SPECT data, normalization methods, loss function optimization, and up-sampling techniques for optimal mu-map generation. The problem of checkerboard artifacts, unique to mu-map generation from SPECT signals, and the effects of iodine contrast media were evaluated. The addition of scattering SPECT to primary emission SPECT imaging, logarithmic maximum normalization, the combination of absolute difference loss (L1) and three times the absolute gradient difference loss (3 x LGDL), and the nearest-neighbor interpolation significantly enhanced AI performance in mu-map generation (p < 0.00001). Checkerboard artifacts were effectively eliminated using the nearest-neighbor interpolation technique. The developed AI algorithm produced mu-maps neutral to the presence of iodine contrast and showed negligible contrast effects on quantitative SPECT measurement, such as glomerular filtration rate (GFR). The potential reduction in radiation exposure by transitioning to AI-based CT-free SPECT imaging ranges from 45.3 to 78.8%. Conclusion The study successfully developed and optimized a deep learning algorithm for generating synthetic mu-maps in kidney SPECT images, demonstrating the potential to transition from conventional SPECT/CT to CT-free SPECT imaging for GFR measurement. This advancement represents a significant step towards enhancing patient safety and efficiency in nuclear medicine.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    KNOLL, GF
    PROCEEDINGS OF THE IEEE, 1983, 71 (03) : 320 - 329
  • [42] Single photon emission computed tomography in tuberculous meningitis
    Misra, UK
    Kalita, J
    Das, BK
    POSTGRADUATE MEDICAL JOURNAL, 2000, 76 (900) : 642 - 645
  • [43] SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    UREN, RF
    MAGISTRETTI, PL
    ROYAL, HD
    PARKER, JA
    FRONT, D
    HILL, TC
    HOLMAN, BL
    JONES, AG
    KOLODNY, GM
    MEDICAL JOURNAL OF AUSTRALIA, 1983, 1 (09) : 411 - 413
  • [44] Prognostic impact of myocardial perfusion single photon emission computed tomography in patients with major extracardiac findings by computed tomography for attenuation correction
    Charline Zadro
    Noé Roussel
    Emmanuelle Cassol
    Pierre Pascal
    Antoine Petermann
    Olivier Meyrignac
    Marion Jaffro
    Pauline Fournier
    Maxime Cournot
    Michel Galinier
    Didier Carrié
    Hervé Rousseau
    Isabelle Berry
    Olivier Lairez
    Journal of Nuclear Cardiology, 2018, 25 : 1574 - 1583
  • [45] Deep-learning-based model observer for a lung nodule detection task in computed tomography
    Gong, Hao
    Hu, Qiyuan
    Walther, Andrew
    Koo, Chi Wan
    Takahashi, Edwin A.
    Levin, David L.
    Johnson, Tucker F.
    Hora, Megan J.
    Leng, Shuai
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Yu, Lifeng
    JOURNAL OF MEDICAL IMAGING, 2020, 7 (04)
  • [46] Prognostic impact of myocardial perfusion single photon emission computed tomography in patients with major extracardiac findings by computed tomography for attenuation correction
    Zadro, Charline
    Roussel, Noe
    Cassol, Emmanuelle
    Pascal, Pierre
    Petermann, Antoine
    Meyrignac, Olivier
    Jaffro, Marion
    Fournier, Pauline
    Cournot, Maxime
    Galinier, Michel
    Carrie, Didier
    Rousseau, Herve
    Berry, Isabelle
    Lairez, Olivier
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (05) : 1574 - 1583
  • [47] Single-photon emission computed tomography/computed tomography: Basic instrumentation and innovations
    O'Connor, Michael K.
    Kemp, Brad J.
    SEMINARS IN NUCLEAR MEDICINE, 2006, 36 (04) : 258 - 266
  • [48] Single photon emission computed tomography/computed tomography of the skull in malignant otitis externa
    Chakraborty, Dhritiman
    Bhattacharya, Anish
    Kamaleshwaran, Koramadai Karuppusamy
    Agrawal, Kanhaiyalal
    Gupta, Ashok Kumar
    Mittal, Bhagwant Rai
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2012, 33 (01) : 128 - 129
  • [49] Deep learning-based generation of SPECT Emission only attenuation "μ"-map depends on the specific of the tracer uptake
    Ding, Xinhong
    Vija, Alexander Hans
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [50] Endocrine radionuclide scintigraphy with fusion single photon emission computed tomography/computed tomography
    Wong, Ka-Kit
    Gandhi, Arpit
    Viglianti, Benjamin L.
    Fig, Lorraine M.
    Rubello, Domenico
    Gross, Milton D.
    WORLD JOURNAL OF RADIOLOGY, 2016, 8 (06): : 635 - 655