A modified Radiographic Union Score for Tibia (RUST) scoring system for patella fractures treated with osteosynthesis shows excellent intra und interobserver reliability

被引:0
|
作者
Lenz, Julia Elisabeth [1 ]
Huber, Lorenz [1 ]
Szymski, Dominik [1 ]
Alt, Volker [1 ]
Rupp, Markus [1 ]
Weber, Johannes [1 ]
机构
[1] Univ Hosp Regensburg, Regensburg, Germany
关键词
RUST; Patella; Fracture; Osteosynthesis; Reliability; COMPUTED-TOMOGRAPHY; PLAIN RADIOGRAPHY;
D O I
10.1007/s00402-024-05736-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Patellar fractures are rare at 1% incidence of all fractures. However, they can cause significant functional impairments due to the patella's role in knee joint extension. Current scoring systems lack objectivity in assessing patellar healing. This study aims to validate the Radiographic Union Score for Tibia (RUST) using biplanar radiographs for assessing surgically treated patellar fractures.Materials and methods A retrospective analysis of radiological follow-up examinations was conducted on patients undergoing surgical treatment for patellar fractures from January 1st 2013, to June 30th 2023. Thirty patients were randomly selected, yielding 105 postoperative X-rays representing various healing stages. The modified Radiographic Union Score for Tibia (RUST) was applied to these X-rays by three independent trauma surgeons. Radiological follow-up examinations were randomized, pseudonymized, and stored on a hospital server for blinded assessment by three raters. The modified RUST assessed continuity of patellar borders and cortexes, assigning scores based on cortical bridging. Interobserver and intraobserver reliability were evaluated using intraclass correlation coefficients (ICC), adhering to recommended sample size criteria and interpretation guidelines.Results The mean modified RUST was 9.1 +/- 2.2 points, with scores ranging from 4 to 12 points. The interobserver intraclass correlation coefficient (ICC) was 0.88 (95% CI, 0.81-0.92) and the intraobserver ICC were 0.6 (95% CI, 0.65-0.84), 0.80 (95% CI, 0.71-0.87) and 0.98 (0.98-0.99) respectively, which indicated good to excellent agreement.Conclusions This study validated the Radiographic Union Score for Tibia (RUST) for evaluating bone healing in patellar fractures treated with osteosynthesis, demonstrating good intra- and interobserver reliability. The modified RUST can provide a standardized method for assessing healing in patellar fractures, benefiting both clinical practice and clinical trials.
引用
收藏
页数:5
相关论文
共 5 条
  • [1] Radiographic union score for tibia (RUST) scoring system in adult diaphyseal femoral fractures treated with intramedullary nailing: an assessment of interobserver and intraobserver reliability
    Pravesh Panchoo
    Maritz Laubscher
    Michael Held
    Sithombo Maqungo
    Nando Ferreira
    Hamish Simpson
    Simon Matthew Graham
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 1555 - 1559
  • [2] Radiographic union score for tibia (RUST) scoring system in adult diaphyseal femoral fractures treated with intramedullary nailing: an assessment of interobserver and intraobserver reliability
    Panchoo, Pravesh
    Laubscher, Maritz
    Held, Michael
    Maqungo, Sithombo
    Ferreira, Nando
    Simpson, Hamish
    Graham, Simon Matthew
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (08) : 1555 - 1559
  • [3] Reliability of the Modified Radiographic Union Score for Tibia Fractures (mRUST) for Femoral Shaft Fractures
    Schmidt, Gregory
    Foley, David
    Simpson, Austin
    Farooq, Hassan
    Sharma, Ishani
    Slaven, James
    Lopas, Luke
    Jang, Yohan
    McKinley, Todd
    Mullis, Brian
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (04) : E143 - E146
  • [4] Evaluation of Fracture and Osteotomy Union in the Setting of Osteogenesis Imperfecta: Reliability of the Modified Radiographic Union Score for Tibial Fractures (RUST)
    Franzone, Jeanne M.
    Finkelstein, Mark S.
    Rogers, Kenneth J.
    Kruse, Richard W.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2020, 40 (01) : 48 - 52
  • [5] Reliability of Modified Radiographic Union Score for Tibia Scores in the Evaluation of Femoral Shaft Fractures in a Low-resource Setting
    Urva, Mayur
    Challa, Sravya T.
    Haonga, Billy T.
    Eliezer, Edmund
    Working, Zachary M.
    El Naga, Ashraf
    Morshed, Saam
    Shearer, David W.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS GLOBAL RESEARCH AND REVIEWS, 2022, 6 (05):