Shear capacity analysis of fiber reinforced polymer concrete beams

被引:0
作者
Mohammed Sharif [1 ]
机构
[1] Jamia Millia Islamia Central University,Department of Civil Engineering
来源
Discover Civil Engineering | / 1卷 / 1期
关键词
Carbon; Glass; Fiber; Reinforcement; Shear; Capacity; Design standards;
D O I
10.1007/s44290-024-00127-2
中图分类号
学科分类号
摘要
In recent years, fiber reinforced polymer (FRP) reinforcement has garnered significant interest in the construction industry, particularly in concrete beam construction. Determining the shear capacity of FRP-reinforced beams is, however, an intricate task. The shear capacity of FRP-reinforced concrete beams can be estimated using design equations from various international standards of practice. However, these equations are often adaptations of those used for conventional steel reinforcement, resulting in unreliable estimates. This research compares design equation predictions with experimental data, utilizing test results from 48 carbon FRP-reinforced and 73 glass FRP-reinforced concrete beams. The results reveal significant differences in the accuracy and reliability of shear capacity predictions using American (ACI), Canadian (CSA), and Japanese (JSCE) design standards for both types of concrete beams. The ACI standard has high underestimation and inconsistent predictions for carbon and glass FRP beams, making it unsuitable for shear design. The CSA standard provides consistent predictions with moderate underestimation for both types of FRP beams, but it shows overestimation in certain cases. The JSCE standard consistently shows moderate underestimation without any instances of overestimation, making it a reliable tool for engineers and practitioners to estimate the shear capacity of both types of FRP-reinforced beams.
引用
收藏
相关论文
共 70 条
[1]  
Akkaya HC(2022)Investigation on shear behavior of reinforced concrete deep beams without shear reinforcement strengthened with fiber reinforced polymers Case Stud Constr Mater 17 119-126
[2]  
Aydemir C(2022)Investigation on shear behavior of reinforced concrete deep beams without shear reinforcement strengthened with fiber reinforced polymers Case Stud Constr Mater 299 507-516
[3]  
Arslan G(2024)Evaluation of shear behavior of short-span reinforced concrete deep beams strengthened with fiber reinforced polymer strips Eng Struct 16 819-828
[4]  
Akkaya HC(2012)Effect of member depth on shear strength of high strength fiber-reinforced polymer–reinforced concrete beams J Compos Constr 17 15-24
[5]  
Aydemir C(2013)Size effect on shear strength of FRP-reinforced concrete beams without stirrups J Compos Constr 154 37-42
[6]  
Arslan G(2017)Relationship between the shear capacity and the flexural cracking load of FRP reinforced concrete beams Constr Build Mater 72 1005-1015
[7]  
Akkaya HC(2014)Shear behavior of concrete beams reinforced with carbon fiber-reinforced polymer (CFRP) stirrups Constr Build Mater 25 4710-4717
[8]  
Aydemir C(2003)Strengthening of concrete structures using FRP composites Concr Int 20 1903-1915
[9]  
Arslan G(2006)Flexural and shear capacities of concrete beams reinforced with GFRP bars Constr Build Mater 23 383-389
[10]  
Alam MS(2019)Experimental study on the flexural behaviour of a novel concrete filled hybrid beams reinforced with GFRP and steel bars KSCE J Civ Eng 279 235-243