Use of double short tandem scleral tunnels for repairing eroded ahmed glaucoma valve tubes

被引:0
作者
Yu, Jun [1 ]
Dai, Xiangjun [1 ]
Chen, Xiaohua [1 ]
Gao, Xiaoming [2 ]
Pan, Weihua [3 ]
机构
[1] Zhejiang Yiwu Aier Eye Hosp, Dept Ophthalmol, Jinhua 322000, Peoples R China
[2] Zhejiang Ningbo Aier Eye Hosp, Dept Ophthalmol, Ningbo 315100, Peoples R China
[3] Zhejiang Hangzhou Aier Eye Hosp, Dept Ophthalmol, Hagzhou 311200, Peoples R China
关键词
Ahmed glaucoma valve; Double short tandem scleral tunnels; Tube erosion; EXPOSURE; IMPLANT; MEMBRANE;
D O I
10.1186/s12886-024-03694-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo evaluate the effectiveness and safety of a method for repairing an eroded Ahmed glaucoma valve (AGV) tube using two short scleral tunnels made in tandem with a 22G needle instead of covering the eroded tube with another scleral graft.MethodsFrom May 12, 2015, to July 27, 2019, we retrospectively reviewed eight patients at Ningbo Aier Eye Hospital who developed AGV tube erosion secondary to necrosis of their overlying conjunctiva and scleral grafts. This defect was repaired in all the patients using the double short tandem scleral tunnel technique, which involved the creation of double short tandem scleral tunnels made by a 22G needle. Two parallel-to-limbus scleral incisions were made 3 mm and 6 mm from the limbus first, then a curved 22G needle was inserted between the two scleral cuts to make one scleral tunnel, the other scleral tunnel was completed during the first surgery, inserted the tube into the two tunnels. The mean length of time between the AGV placement and the first erosion was 12.25 +/- 6.36 months (3-24 months). The mean age of the patients was 65.50 +/- 11.70 years (49-78 years).ResultsThe surgical outcome was assessed in terms of the tectonic integrity of the conjunctiva over the follow-up period (12 months). There was no AGV tube erosion, scleral thinning, or ocular infection after a mean of 41.25 +/- 26.54 months of follow-up in all eight patients.ConclusionAGV tube erosion following shunt surgery can be successfully managed using the improved double short tandem scleral tunnel technique.
引用
收藏
页数:6
相关论文
共 22 条
  • [21] Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study
    San Pedro, Marie Jeremy B.
    Gomez, James Paul S.
    Leuenberger, Edgar U.
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 1691 - 1699
  • [22] Bleb Analysis and Short- Term Results of Biodegradable Collagen Matrix-Augmented Ahmed Glaucoma Valve Implantation: 6-Month Follow-up
    Rho, Seungsoo
    Sung, Youngje
    Ma, Kyoung Tak
    Rho, Sae Heun
    Kim, Chan Yun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (10) : 5896 - 5903