Advancing patient safety in interventional radiology: effective dose evaluation and LDRL

被引:0
作者
Alvarez, M. [1 ]
Guassu, R. A. C. [2 ]
Rosa, A. A. [3 ]
de Sousa, R. R. [2 ]
de Pina, D. R. [4 ]
机构
[1] Botucatu Med Sch, Clin Hosp, Med Phys & Radioprotect Nucleus, Botucatu, Brazil
[2] Sao Paulo State Univ, Inst Biosci, Botucatu, Brazil
[3] Botucatu Med Sch, Hosp Clin, Med Phys Radiodiag, Botucatu, Brazil
[4] Sao Paulo State Univ, Botucatu Med Sch, Dept Infect Dis Dermatol Diagnost Imaging & Radiot, Botucatu, Brazil
关键词
radiation protection; fluoroscopy; radiation dose; DIAGNOSTIC REFERENCE LEVELS; RADIATION-EXPOSURE; FLUOROSCOPY; ACQUISITION; REDUCTION;
D O I
10.1051/radiopro/2024031
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study highlights the significance of radioprotection in interventional radiology, focusing on the assessment of Effective Dose values to which patients are exposed. To facilitate this, we developed a semi-automatic software employing Optical Character Recognition technology. This software analysed 1334 interventional procedures conducted between January 2021 and September 2023 at a large Brazilian hospital. The database includes the type of procedure, Air Kerma value, Kerma-Area Product, number of cineangiography images, and exposure duration, all realized on an Artis Zee (R) (Siemens Healthineers, Germany) C-arm. We established Local Diagnostic Reference Levels (LDRLs) and calculated Effective Dose values using the PCXMC 2.0 Monte Carlo simulation software. These calculations were based on data from the hospital and LDRLs determined in subsequent studies. The findings reveal that both the LDRLs and the calculated Effective Dose generally fall below the values reported in existing literature. This underscores the efficacy of our methodology in enhancing radioprotection and dose monitoring within the studied hemodynamics sector.
引用
收藏
页码:28 / 36
页数:9
相关论文
共 23 条
[1]  
[Anonymous], 2007, The 2007 Recommendations of the International Commission on Radiological Protection, DOI [DOI 10.1016/J.ICRP.2007.10.005.ANN.ICRP37, DOI 10.1016/J.ICRP.2007.10.003]
[2]   How to set up and apply reference levels in fluoroscopy at a national level [J].
Aroua, A. ;
Rickli, H. ;
Stauffer, J.-C. ;
Schnyder, P. ;
Trueb, P. R. ;
Valley, J.-F. ;
Vock, P. ;
Verdun, F. R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1621-1633
[3]   Does cardiologist- or radiographer-operated fluoroscopy and image acquisition influence optimization of patient radiation exposure during routine coronary angiography? [J].
Arthur, WR ;
Dhawan, J ;
Norell, MS ;
Hunter, AJ ;
Clark, AL .
BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (897) :748-753
[4]   The growing potential of diagnostic reference levels as a dynamic tool for dose optimization [J].
Damilakis, J. ;
Vassileva, J. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 84 :285-287
[5]   Patient dosimetry in arteriography of the lower limbs. Part I: Quantification of exposure [J].
Kicken, PJH ;
Kemerink, GJ ;
van Engelshoven, JMA .
RADIATION PROTECTION DOSIMETRY, 1999, 81 (01) :25-36
[6]   OCCUPATIONAL RADIATION DOSES TO OPERATORS PERFORMING FLUOROSCOPICALLY-GUIDED PROCEDURES [J].
Kim, Kwang Pyo ;
Miller, Donald L. ;
de Gonzalez, Amy Berrington ;
Balter, Stephen ;
Kleinerman, Ruth A. ;
Ostroumova, Evgenia ;
Simon, Steven L. ;
Linet, Martha S. .
HEALTH PHYSICS, 2012, 103 (01) :80-99
[7]  
Laura, 2015, NCRP Report 160-NCRP | Bethesda, MD
[8]   Effective Dose Assessment for Patients Undergoing Contemporary Fluoroscopically Guided Interventional Procedures [J].
Li, Xinhua ;
Hirsch, Joshua A. ;
Rehani, Madan M. ;
Yang, Kai ;
Liu, Bob .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (01) :158-170
[9]   Radiation dose management systems-requirements and recommendations for users from the ESR EuroSafe Imaging initiative [J].
Loose, Reinhard W. ;
Vano, Eliseo ;
Mildenberger, Peter ;
Tsapaki, Virginia ;
Caramella, Davide ;
Sjoberg, Johan ;
Paulo, Graciano ;
Torresin, Alberto ;
Schindera, Sebastian ;
Frija, Guy ;
Damilakis, John .
EUROPEAN RADIOLOGY, 2021, 31 (04) :2106-2114
[10]  