Simplified Second-Order Analysis of Slender FRP-Reinforced Concrete Columns Using the Nominal Curvature Method

被引:1
作者
Syed, Ahmed Usama [1 ]
Goldack, Arndt [1 ]
机构
[1] Univ Wuppertal, Fac Architecture & Civil Engn, D-42119 Wuppertal, Germany
关键词
Slender columns; Fiber-reinforced polymer (FRP) bars; FRP bar-RC; Second-order analysis; Nominal curvature; Stability; RC COLUMNS; DESIGN;
D O I
10.1061/JCCOF2.CCENG-4944
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The nominal curvature method is one of the simplified methods for the second-order analysis of steel-RC columns in design codes. The two parameters that are important in the application of this method are the total curvature distribution factor and the nominal curvature. Generally, for steel-RC columns, nominal curvature can be reasonably estimated from the curvature of the cross section for a balanced failure and linear interpolation is performed for load values other than the balanced failure load. However, when fiber-reinforced polymer (FRP) bars are used as a reinforcement for concrete columns, the balance point may not appear in the load-moment capacity curve or may appear at a very low load value and not at the knee bend of the load-moment capacity curve. Due to such behavior of FRP bar-RC (FRP-RC) columns, the estimation of nominal curvature is complex. This work examines the application of the nominal curvature method for the second-order analysis of FRP-RC columns and presents an equation based on a parametric study to estimate the nominal curvature of FRP-RC columns. In addition, when applying the nominal curvature method, the total curvature distribution factor is normally assumed as 10, which may be unconservative in some cases. In this work, an equation is presented to reasonably estimate the total curvature distribution factor, both for steel-RC and FRP-RC columns. Furthermore, a worked-out example and load-moment capacity curves for cross-sectional analysis are presented for FRP-RC columns. The outcomes would be of benefit for developing the design standards for FRP-RC structures and the simplified second-order analysis of RC columns.
引用
收藏
页数:16
相关论文
共 33 条
[1]   Proposed Flexural Stiffness of Slender Concrete Columns Reinforced with Glass Fiber-Reinforced Polymer Bars [J].
Abdelazim, Waseem ;
Mohamed, Hamdy M. ;
Benmokrane, Brahim .
ACI STRUCTURAL JOURNAL, 2021, 118 (01) :227-240
[2]   Experimental Investigation of Large-Scale Eccentrically Loaded GFRP-Reinforced High-Strength Concrete Columns [J].
Almomani, Mu'taz ;
Mahmoud, Karam ;
El-Salakawy, Ehab F. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2022, 26 (02)
[3]  
[Anonymous], 2022, Matlab version: 9.13.0 (r2022b)
[4]  
[Anonymous], 2022, Building Code Requirements for Structural Concrete and Commentary
[5]  
[Anonymous], 2008, 318 ACI
[6]  
[Anonymous], 2013, fib model code for concrete structures 2010
[7]  
[Anonymous], 2005, EN 1992-1-1:2005
[8]  
Beeby A. W., 2005, Design of concrete structures: General rules and rules for buildings and structural fire design
[9]  
Broms BB, 1956, Ultimate Strength of Long Reinforced Concrete Columns
[10]  
CARRASQUILLO RL, 1981, J AM CONCRETE I, V78, P171