Visual and patient reported outcomes provided by a refractive multifocal intraocular lens based on continuous transitional focus

被引:0
作者
Alio, Jorge L. [1 ,2 ,8 ]
Martinez-Abad, Antonio [1 ]
Ruiz-Mesa, Ramon [3 ]
Kim, Hyo Myung [4 ]
Mendicute, Javier [5 ]
Ribeiro, Filomena J. [6 ]
Holzer, Mike P. [7 ]
Canto-Cerdan, Mario [1 ]
机构
[1] Vissum Miranza, Avda Denia S-N Edificio Vissum, Alicante 03016, Spain
[2] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
[3] Oftalvist CIO Jerez, Cadiz, Spain
[4] Korea Univ, Anam Hosp, Dept Ophthalmol, Seoul, South Korea
[5] Hosp Univ Donostia, Dept Ophthalmol, San Sebastian, Spain
[6] Univ Lisbon, Hosp Luz Lisboa, Dept Oftalmol, Lisbon, Portugal
[7] Heidelberg Univ, Int Vis Correct Res Ctr IVCRC, Dept Ophthalmol, Heidelberg, Germany
[8] Avda Denia S-N,Edificio Vissum, Alicante 03016, Spain
关键词
BILATERAL IMPLANTATION; EXTENDED DEPTH; CLINICAL-OUTCOMES; ACRYSOF RESTOR; CATARACT; QUALITY; PERFORMANCE; ASTIGMATISM; VISION;
D O I
10.1186/s40662-024-00408-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo analyze the quality of vision of patients implanted bilaterally with the multifocal Precizon Presbyopic intraocular lens (IOL), as well as to evaluate the visual performance provided by the lens.SettingVissum Miranza Alicante.DesignProspective multicenter study.Methods56 patients (mean age 65.0 +/- 8.7 years old) underwent bilateral implantation with multifocal Precizon Presbyopic IOL. The quality of vision was assessed by a quality of vision questionnaire at 6 months after the implantation procedure, a complete eye examination was also performed including visual and refractive measurements, defocus curve and contrast sensitivity assessment. Visual and refractive variables were compared in preoperative, 3-month postoperative and 6-month postoperative visits by Wilcoxon test.ResultsThe quality of vision analysis showed the absence of severe glare and severe haloes in all evaluated patients. Likewise, non-symptoms of glare, haloes and starbursts were seen in 75%, 68%, and 55% of subjects, respectively. Efficacy and safety index was 1.26 and 1.42, respectively. The 6-month postoperative binocular uncorrected distance visual acuity and near uncorrected visual acuity were 0.00 +/- 0.09 and 0.20 +/- 0.13 logMAR, respectively. Mean spherical equivalent was 0.29 +/- 0.45 D.ConclusionsThe Precizon Presbyopic NVA IOL (OPHTEC BV) provides a suitable quality of vision with a low rate of disturbance photic phenomena induction, as well as an excellent visual performance at main distances of sight accomplishing the visual demands of the majority of patients.
引用
收藏
页数:10
相关论文
共 33 条
[1]   Clinical Retinal Image Quality of a Non-diffractive Wavefront-Shaping Extended Depth of Focus (Vivity) Intraocular Lens [J].
Al-Amri, Saad Abdulrahman J. ;
Alio, Jorge L. ;
Milan-Castillo, Roberto ;
D'Oria, Francesco ;
Martinez-Abad, Antonio ;
Yebana, Pilar ;
Subirana, Nuria ;
Al-Harbi, Ziyad ;
Plaza-Puche, Ana B. ;
Alio del Barrio, Jorge L. .
JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (02) :103-+
[2]   Multifocal intraocular lens exchange to monofocal for the management of neuroadaptation failure [J].
Al-Shymali, Olena ;
Alio del Barrio, Jorge L. ;
McAlinden, Colm ;
Canto, Mario ;
Primavera, Laura ;
Alio, Jorge L. .
EYE AND VISION, 2022, 9 (01)
[3]   Patients' dissatisfaction with multifocal intraocular lenses managed by exchange with other multifocal lenses of different optical profiles [J].
Al-Shymali, Olena ;
McAlinden, Colm ;
Alio del Barrio, Jorge L. ;
Canto-Cerdan, Mario ;
Alio, Jorge L. .
EYE AND VISION, 2022, 9 (01)
[4]   Contrast Sensitivity Comparison Between AcrySof ReSTOR and Acri.LISA Aspheric Intraocular Lenses [J].
Alfonso, Jose F. ;
Puchades, Cristina ;
Fernandez-Vega, Luis ;
Merayo, Carmen ;
Montes-Mico, Robert .
JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (07) :471-477
[5]   Retinal image quality with multifocal, EDoF, and accommodative intraocular lenses as studied by pyramidal aberrometry [J].
Alio, Jorge L. ;
D'Oria, Francesco ;
Toto, Francesca ;
Balgos, Joan ;
Palazon, Antonio ;
Versaci, Francesco ;
Alio del Barrio, Jorge L. .
EYE AND VISION, 2021, 8 (01)
[6]   Clinical outcomes with a new design in multifocal intraocular lens: a pilot study [J].
Alio, Jorge L. ;
Yebana, Pilar ;
Canto, Mario ;
Plaza, Ana B. ;
Vega, Alfredo ;
Alio del Barrio, Jorge L. ;
Lugo, Francisco .
EYE AND VISION, 2020, 7 (01)
[7]   Clinical outcomes with a diffractive trifocal intraocular lens [J].
Alio, Jorge L. ;
Plaza-Puche, Ana B. ;
Alio del Barrio, Jorge L. ;
Amat-Peral, Pedro ;
Ortuno, Vicente ;
Yebana, Pilar ;
Al-Shymali, Olena ;
Vega-Estrada, Alfredo .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (04) :419-424
[8]   Multifocal intraocular lenses: An overview [J].
Alio, Jorge L. ;
Plaza-Puche, Ana B. ;
Fernandez-Buenaga, Roberto ;
Pikkel, Joseph ;
Maldonado, Miguel .
SURVEY OF OPHTHALMOLOGY, 2017, 62 (05) :611-634
[9]   Visual Outcomes of a Trifocal Aspheric Diffractive Intraocular Lens With Microincision Cataract Surgery [J].
Alio, Jorge L. ;
Montalban, Raul ;
Pena-Garcia, Pablo ;
Soria, Felipe A. ;
Vega-Estrada, Alfredo .
JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (11) :756-761
[10]   Visual outcomes with a single-optic accommodating intraocular lens and a low-addition-power rotational asymmetric multifocal intraocular lens [J].
Alio, Jorge L. ;
Plaza-Puche, Ana B. ;
Montalban, Raul ;
Javaloy, Jaime .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06) :978-985