Direct versus fully digital indirect bracket bonding: a split-mouth randomized clinical trial on accuracy

被引:1
作者
Hoekstra-van Hout, Pauline M. J. [1 ]
Hoekstra, Jan Willem M. [1 ]
Bruggink, Robin [2 ]
Bronkhorst, Ewald M. [1 ]
Ongkosuwito, Edwin M. [1 ]
机构
[1] Radboud Univ Nijmegen Med Ctr, Dept Dent Sect Orthodont & Craniofacial Biol, POB 9101,THK 309, NL-6500 HB Nijmegen, Netherlands
[2] Radboud Univ Nijmegen Med Ctr, Radboudumc 3DLab, Nijmegen, Netherlands
关键词
Orthodontics; Bracket placement; Indirect bracket bonding; Computer-aided design; Chairside time; Fixed appliances; PLACEMENT; SYSTEM;
D O I
10.1007/s00784-024-05950-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The primary aim is to assess differences in accuracy of orthodontic bracket positioning between fully digital indirect bracket bonding (IDB) and conventional direct bracket bonding (DBB). The secondary aims are to assess differences in bracket bonding failures, bracket repositioning need, clinician experience and patient satisfaction. Materials and methods This prospective study was designed as a split-mouth randomized clinical trial. In total, 35 patients were analyzed with a six month follow-up period. Translational and orientational deviations from the planned bracket position were determined. Clinician experience and patient satisfaction were evaluated by means of a survey. Results The difference in translation was 0.34 mm (95% CI: 0.238-0.352, p = 0.017), the difference in orientation was 4.80 & ring; (95% CI: 3.858-5.727, p < 0.001), both in favour of IDB. IDB showed significantly more immediate (IDB: 3.9%, DBB: 0%) and late (IDB: 5.4%, DBB: 2.5%, p = 0.008) bonding failures. Clinicians and patients experienced a shorter clinical chair time with indirect bonding over direct bonding. Conclusions IDB bracket positioning leads to significant smaller translation and orientation deviations from digital IDB planning, than DBB bracket positioning. However, IDB leads to more immediate bonding failures than DBB. The majority of patients preferred IDB over DBB, due to a shorter clinical chair time. Clinical relevance This study adds to the knowledge of IDB in orthodontics and contributes to evidence on this technique. This evidence is applicable in everyday orthodontics, with respect to patient satisfaction and technical limits of IDB.
引用
收藏
页数:12
相关论文
共 21 条
  • [11] McLaughlin R P, 1995, J Clin Orthod, V29, P302
  • [12] PREADJUSTED EDGEWISE APPLIANCES - THEORY AND PRACTICE
    MEYER, M
    NELSON, G
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1978, 73 (05) : 485 - 498
  • [13] Effect of variation in tooth morphology and bracket position on first and third order correction with preadjusted appliances
    Miethke, RR
    Melsen, B
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1999, 116 (03) : 329 - 335
  • [14] Oliveira Natalice Sousa de, 2019, Dental Press J. Orthod., V24, P46, DOI 10.1590/2177-6709.24.4.046-053.oar
  • [15] Accuracy of indirect bracket placement with medium-soft, transparent, broad-coverage transfer trays fabricated using computer-aided design and manufacturing: An in-vivo study
    Palone, Mario
    Koch, Petra-Julia
    Jost-Brinkmann, Paul -Georg
    Spedicato, Giorgio Alfredo
    Verducci, Alessandro
    Pieralli, Patrizia
    Lombardo, Luca
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2023, 163 (01) : 33 - 46
  • [16] Three-Dimensional Digital Superimposition of Orthodontic Bracket Position by Using a Computer-Aided Transfer Jig System: An Accuracy Analysis
    Park, Jae-Hyun
    Choi, Jin-Young
    Oh, Song Hee
    Kim, Seong-Hun
    [J]. SENSORS, 2021, 21 (17)
  • [17] Rachala Madhukar Reddy, 2010, Int J Orthod Milwaukee, V21, P31
  • [18] Schulz KF, 2010, BMJ-BRIT MED J, V340, DOI [10.1136/bmj.c869, 10.1136/bmj.c332, 10.1016/j.ijsu.2011.09.004, 10.1016/j.jclinepi.2010.02.005, 10.1186/1741-7015-8-18, 10.4103/0976-500X.72352]
  • [19] UNIVERSAL DIRECT BONDING SYSTEM FOR BOTH METAL AND PLASTIC BRACKETS
    SILVERMAN, E
    DIETZ, VS
    GIANELLY, AA
    COHEN, M
    [J]. AMERICAN JOURNAL OF ORTHODONTICS, 1972, 62 (03): : 236 - +
  • [20] A clinical comparison of bracket bond failures in association with direct and indirect bonding
    Thiyagarajah, S.
    Spary, D. J.
    Rock, W. P.
    [J]. JOURNAL OF ORTHODONTICS, 2006, 33 (03) : 198 - 204