Agreement of intraocular pressure measurement by scleral Schiotz and Goldmann applanation tonometer

被引:0
|
作者
Shaikh, Zeba Muzammil [1 ]
Rajalakshmi, A. R. [1 ]
Nagarajan, Swathi [1 ]
Lokeshmaran, A. [2 ]
机构
[1] Deemed Be Univ, Sri Balaji Vidyapeeth SBV, Mahatma Gandhi Med Coll & Res Inst, Dept Ophthalmol, Pondicherry, India
[2] Deemed Be Univ, Sri Balaji Vidyapeeth SBV, Mahatma Gandhi Med Coll & Res Inst, Dept Community Med, Pondicherry, India
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
Corneal IOP; Intraocular pressure estimation; Ocular rigidity; Predictive formula for IOP; Schiotz tonometer; Scleral biomechanics; Scleral IOP; CORNEAL; PNEUMATONOMETRY; THICKNESS;
D O I
10.1038/s41598-024-79403-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Aim & background : Intraocular pressure (IOP) measured through the sclera has some advantages over IOP measured through cornea. This study aimed to determine the agreement between IOP as estimated by scleral Schiotz (SS) tonometer and Goldmann applanation tonometer (GAT). Methods: In this cross-sectional observational study, IOP was measured by GAT on the cornea and Schiotz tonometer on the temporal sclera. Axial length and central corneal thickness (CCT) were noted. IOP was then estimated from SS IOP as eGAT using a predictive formula. Agreement of IOP corrected for CCT (cGAT) with eGAT and SS IOP were assessed. The effects of age, axial length, refraction, CCT, gender, and ocular and systemic comorbidity on measured IOP were also assessed. Results: The study included 155 patients with a mean age of 54.27 +/- 10.02 years. Mean IOP measured by GAT and scleral Schiotz were 16.58 +/- 2.76 mm Hg and 16.10 +/- 2.96 mm Hg, respectively. The mean IOP by cGAT and eGAT were 16.70 +/- 2.80 mm Hg and 17.07 +/- 3.10 mm Hg, respectively. Both eGAT & SS IOP had good agreement with cGAT on the Bland-Altmann plot (p = 0.96 & 0.51, respectively). Further, SS IOP showed good agreement even with GAT IOP (p = 0.78). Age, axial length, refraction, central corneal thickness, gender, and ocular and systemic comorbidity did not show significant correlation with IOP measurement. Conclusion: Estimated GAT IOP showed good agreement with measured GAT values. SS IOP also agreed well with GAT IOP. Clinical significance IOP measurement on the sclera using Schiotz can be used as an alternative to GAT.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Accurate intraocular pressure prediction from applanation response data using genetic algorithm and neural networks
    Ghaboussi, Jamshid
    Kwon, Tae-Hyun
    Pecknold, David A.
    Hashash, Youssef M. A.
    JOURNAL OF BIOMECHANICS, 2009, 42 (14) : 2301 - 2306
  • [42] Correlation Between Corneal and Sclera! Pneumatonometry: An Alternative Method for Intraocular Pressure Measurement
    Kapamajian, Michael A.
    de la Cruz, Jose
    Hallak, Joelle A.
    Vajaranant, Thasarat S.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (05) : 902 - 906
  • [43] The Effect of Scleral Buckle Surgery on Tonographic Outflow Facility, Positional Intraocular Pressure, and Ocular Biomechanics
    Lyons, Lance J.
    Kazemi, Arash
    Bakn, Sophie J.
    Barkmeier, Andrew J.
    Iezzi, Raymond
    Olsen, Timothy W.
    Hodge, David O.
    Sit, Arthur J.
    OPHTHALMOLOGY GLAUCOMA, 2024, 7 (01): : 1 - 7
  • [44] Intraocular Pressure Values Obtained by Ocular Response Analyzer, Dynamic Contour Tonometry, and Goldmann Tonometry in Keratokonic Corneas
    Bayer, Atilla
    Sahin, Afsun
    Hurmeric, Volkan
    Ozge, Gokhan
    JOURNAL OF GLAUCOMA, 2010, 19 (08) : 540 - 545
  • [45] Corneal biomechanical properties and intraocular pressure measurement in patients with nanophthalmos
    Altan, Cigdem
    Kara, Necip
    Baz, Okkes
    Satana, Banu
    Demirok, Ahmet
    Yilmaz, Omer Faruk
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (06) : 806 - 810
  • [46] Effect of diabetes mellitus on corneal biomechanics and measurement of intraocular pressure
    Scheler, Annabelle
    Spoerl, Eberhard
    Boehm, Andreas G.
    ACTA OPHTHALMOLOGICA, 2012, 90 (06) : e447 - e451
  • [47] Corneal biomechanical properties and intraocular pressure measurement in Marfan patients
    Kara, Necip
    Bozkurt, Ercument
    Baz, Okkes
    Altinkaynak, Hasan
    Dundar, Huseyin
    Yuksel, Kemal
    Yazici, Ahmet Taylan
    Demirok, Ahmet
    Candan, Sukru
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (02) : 309 - 314
  • [48] Changes in intraocular pressure values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology tonometer (CST) in the early phase after small incision lenticule extraction (SMILE)
    Shen, Yang
    Su, Xiangjian
    Liu, Xiu
    Miao, Huamao
    Fang, Xuejun
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2016, 16 : 1 - 8
  • [49] Corneal Biomechanical Changes After Trabeculectomy and the Impact on Intraocular Pressure Measurement
    Pillunat, Karin R.
    Spoerl, Eberhard
    Terai, Naim
    Pillunat, Lutz E.
    JOURNAL OF GLAUCOMA, 2017, 26 (03) : 278 - 282
  • [50] Comparison of intraocular pressure measurements using rebound (TonoVet®) and applanation (TonoPen-XL®) tonometry in clinically normal alpacas (Vicugna pacos)
    McDonald, Jessica E.
    Knollinger, Amy M.
    Dees, D. Dustin
    MacLaren, Nicole E.
    VETERINARY OPHTHALMOLOGY, 2017, 20 (02) : 155 - 159