Power-energy decoupling with source-typed flexible load: an optimal scheduling strategy for integrated energy systems with multi-flexibility resources

被引:0
|
作者
Shi, Pingyuan [1 ]
Wang, Xingce [1 ]
Hao, Junhong [1 ]
Hong, Feng [2 ]
Liu, Hongtao [3 ]
Du, Xiaoze [1 ]
机构
[1] North China Elect Power Univ, Sch Energy Power & Mech Engn, Key Lab Power Stn Energy Transfer Convers & Syst, Minist Educ, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, Sch Control & Comp Engn, State Key Lab Alternate Elect Power Syst Renewable, Beijing 102206, Peoples R China
[3] North China Elect Power Univ, Natl Inst Energy Dev Strategy, Beijing 102206, Peoples R China
来源
CARBON NEUTRALITY | 2025年 / 4卷 / 01期
基金
中国国家自然科学基金;
关键词
Integrated energy system; Heat current method; Optimal scheduling strategy; Demand side response; Flexible load; HEAT-TRANSFER; OPTIMIZATION; MODEL;
D O I
10.1007/s43979-024-00115-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Deep exploration of user-side flexibility resources is crucial for large-scale renewable energy consumption. This paper proposed a typical integrated energy system (IES) that comprehensively includes wind power, photovoltaic, thermal power, combined heat and power, hybrid energy storage, and flexible load and constructed the system's unified power flow model based on the heat current method. On this basis, the regulation capabilities of different typical industrial and residential flexible loads were considered the symmetrical source-type load, which can transfer load and align user demand with the peaks and valleys of renewable energy generation, thus achieving power-energy decoupling. This contributes effectively to renewable energy accommodation capacity when the total electrical energy consumption remains constant. In both typical industrial and residential load scenarios, flexible load reduces integrated costs, increases renewable energy consumption, lowers peak thermal power generation, and decreases the requirement for a battery energy storage system (BESS). Besides, on typical industrial and residential load days, smoothing thermal power generation necessitates 12% and 18% flexible load, respectively, while replacing BESS requires 18% and 23% flexible load, respectively. Therefore, we can obtain the feasible operation ranges of symmetrical source-type load and provide suggestions for configuration capacity design of demand response in integrated energy systems.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Two-stage optimal scheduling of integrated energy system considering source-load uncertainty
    Zhu X.
    Jiang Q.
    Liu M.
    Luo H.
    Long W.
    Huang L.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2023, 43 (08): : 9 - 16and32
  • [22] Optimal planning method of multi-energy storage systems based on the power response analysis in the integrated energy system
    Gao, Mingfei
    Han, Zhonghe
    Zhao, Bin
    Li, Peng
    Wu, Di
    Li, Peng
    JOURNAL OF ENERGY STORAGE, 2023, 73
  • [23] A novel trend and periodic characteristics enhanced decoupling framework for multi-energy load prediction of regional integrated energy systems
    Zhuang, Wei
    Xi, Qingyu
    Lu, Chenxi
    Liu, Ran
    Qiu, Shu
    Xia, Min
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 237
  • [24] Optimal scheduling and routing for integrated power-hydrogen systems in day-ahead energy and flexible ramp product markets
    Habibifar, Reza
    Awad, Ahmed S. A.
    Azzouz, Maher A.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2025, 98 : 1415 - 1429
  • [25] Day-Ahead and Intra-Day Optimal Scheduling of Integrated Energy System Considering Uncertainty of Source & Load Power Forecasting
    Li, Zhengjie
    Zhang, Zhisheng
    ENERGIES, 2021, 14 (09)
  • [26] A two-stage optimal coordinated scheduling strategy for micro energy grid integrating intermittent renewable energy sources considering multi-energy flexible conversion
    Ju, Liwei
    Tan, Qinliang
    Lin, Hongyu
    Mei, Shufang
    Li, Nan
    Lu, Yan
    Wang, Yao
    ENERGY, 2020, 196 (196)
  • [27] Optimization Scheduling Model Based on Source-Load-Energy Storage Coordination in Power Systems
    Li, Yaowang
    Miao, Shihong
    Luo, Xing
    Wang, Jihong
    2016 22ND INTERNATIONAL CONFERENCE ON AUTOMATION AND COMPUTING (ICAC), 2016, : 120 - 125
  • [28] Robust optimal scheduling for integrated energy systems based on multi-objective confidence gap decision theory
    Dong, Yingchao
    Zhang, Hongli
    Wang, Cong
    Zhou, Xiaojun
    EXPERT SYSTEMS WITH APPLICATIONS, 2023, 228
  • [29] Optimal scheduling of park-level integrated energy system considering ladder-type carbon trading mechanism and flexible load
    Sun, Hongbin
    Sun, Xinmei
    Kou, Lei
    Zhang, Benfa
    Zhu, Xiaodan
    ENERGY REPORTS, 2023, 9 : 3417 - 3430
  • [30] Multi-time scale optimal scheduling of integrated energy system considering real-time balancing of multi-energy load fluctuation
    Hu G.
    Li Y.
    Cao Y.
    Zhong J.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2024, 44 (05): : 120 - 126