A prospective observation study of the dynamic monitoring of transcutaneous arterial blood oxygen saturation and carbon dioxide during bronchoscopy

被引:0
|
作者
Shinozaki, Yusuke [1 ]
Morikawa, Kei [1 ]
Hirotaka, Kida [1 ]
Nishiyama, Kazuhiro [1 ]
Tanaka, Satoshi [1 ]
Tsuruoka, Hajime [1 ]
Matsuzawa, Shin [1 ]
Handa, Hiroshi [1 ]
Nishine, Hiroki [1 ]
Mineshita, Masamichi [1 ]
机构
[1] St Marianna Univ, Dept Resp Med, Sch Med, 2-16-1 Sugao,Miyamae Ku, Kawasaki 2168511, Japan
关键词
Bronchoscopy; Dynamic monitoring; Saturation of percutaneous oxygen (SpO(2)); Transcutaneous carbon dioxide partial pressure (tcPCO(2)); FLEXIBLE BRONCHOSCOPY; SEDATION; ANESTHESIA; ACCURACY; PRESSURE;
D O I
10.1186/s12931-024-02990-0
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background and Aims Because bronchoscopy is an invasive procedure, sedatives and analgesics are commonly administered, which may suppress the patient's spontaneous breathing and can lead to hypoventilation and hypoxemia. Few reports exist on the dynamic monitoring of oxygenation and ventilation during bronchoscopy. This study aimed to prospectively monitor and evaluate oxygenation and ventilation during bronchoscopy using transcutaneous arterial blood oxygen saturation and carbon dioxide. Methods We included patients who required pathological diagnosis using fluoroscopic bronchoscopy at our hospital between March 2021 and April 2022. Midazolam was intravenously administered to all patients as a sedative during bronchoscopy, and fentanyl was administered in addition to midazolam when necessary. A transcutaneous blood gas monitor was used to measure dynamic changes, including arterial blood partial pressure of carbon dioxide (tcPCO(2)), transcutaneous arterial blood oxygen saturation (SpO(2)), pulse rate, and perfusion index during bronchoscopy. Quantitative data of tcPCO(2) and SpO(2) were presented as mean +/- standard deviation (SD) (min-max), while the quantitative data of midazolam plus fentanyl and midazolam alone were compared. Similarly, data on sex, smoking history, and body mass index were compared. Subgroup comparisons of the difference (Delta value) between baseline tcPCO(2) at the beginning of bronchoscopy and the maximum value of tcPCO(2) during the examination were performed. Results Of the 117 included cases, consecutive measurements were performed in 113 cases, with a success rate of 96.6%. Transbronchial lung biopsy was performed in 100 cases, whereas transbronchial lung cryobiopsy was performed in 17 cases. Midazolam and fentanyl were used as anesthetics during bronchoscopy in 46 cases, whereas midazolam alone was used in 67 cases. The median Delta value in the midazolam plus fentanyl and midazolam alone groups was 8.10 and 4.00 mmHg, respectively, indicating a significant difference of p < 0.005. The mean +/- standard deviation of tcPCO(2) in the midazolam plus fentanyl and midazolam alone groups was 44.8 +/- 7.83 and 40.6 +/- 4.10 mmHg, respectively. The SpO(2) in the midazolam plus fentanyl and midazolam alone groups was 94.4 +/- 3.37 and 96.2 +/- 2.61%, respectively, with a larger SD and greater variability in the midazolam plus fentanyl group. Conclusion A transcutaneous blood gas monitor is non-invasive and can easily measure the dynamic transition of CO2. Furthermore, tcPCO(2) can be used to evaluate the ventilatory status during bronchoscopy easily. A transcutaneous blood gas monitor may be useful to observe regarding respiratory depression during bronchoscopy, particularly when analgesics are used.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Are Transcutaneous Oxygen and Carbon Dioxide Determinations of Value in Pulmonary Arterial Hypertension?
    Tonelli, Adriano R.
    Alkukhun, Laith
    Cikach, Frank
    Ahmed, Mostafa
    Dweik, Raed A.
    MICROCIRCULATION, 2015, 22 (04) : 249 - 256
  • [22] EFFECTS OF ARTERIAL CARBON DIOXIDE TENSION AND OXYGEN SATURATION ON CEREBRAL BLOOD FLOW AUTOREGULATION IN DOGS
    HAGGENDAL, E
    JOHANSSO.B
    ACTA PHYSIOLOGICA SCANDINAVICA, 1965, S 66 : 27 - +
  • [23] Transcutaneous carbon dioxide monitoring during prolonged apnoea with high-flow nasal oxygen
    Pape, Pernille
    Piosik, Zofia M.
    Kristensen, Camilla M.
    Dirks, Jesper
    Rasmussen, Lars S.
    Kristensen, Michael S.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2023, 67 (05) : 649 - 654
  • [24] Monitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport
    Tingay, DG
    Stewart, MJ
    Morley, CJ
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2005, 90 (06): : F523 - F526
  • [25] A COMPARISON OF ARTERIAL BLOOD GAS SAMPLING AND TRANSCUTANEOUS MONITORING OF OXYGEN (PO2) AND CARBON DIOXIDE (PCO2) DURING THE HYPOXIC ALTITUDE SIMULATION TEST (HAST): A PILOT STUDY
    Jurisevic, M.
    Liu, X.
    Esterman, A.
    Smith, B.
    RESPIROLOGY, 2014, 19 : 130 - 130
  • [26] Transcutaneous carbon dioxide monitoring and capnography during pediatric polysomnography
    Kirk, Valerie G.
    Batuyong, Eldridge D.
    Bohn, Shelly G.
    SLEEP, 2006, 29 (12) : 1601 - 1608
  • [27] OXYGEN AND CARBON DIOXIDE CONTENT OF ARTERIAL BLOOD BEFORE AND DURING SPINAL ANALGESIA
    LATTERELL, KE
    LUNDY, JS
    ANESTHESIOLOGY, 1949, 10 (06) : 677 - 689
  • [28] Transcutaneous carbon dioxide monitoring and capnography during pediatric polysomnography
    Bohn, S
    Kirk, VG
    SLEEP, 2004, 27 : 115 - 115
  • [29] OXYGEN AND CARBON DIOXIDE TENSIONS OF ARTERIAL BLOOD DURING HEAVY AND EXHAUSTIVE EXERCISE
    HOLMGREN, A
    LINDERHOLM, H
    ACTA PHYSIOLOGICA SCANDINAVICA, 1958, 44 (3-4): : 203 - 215
  • [30] OXYGEN CARBON DIOXIDE AND HYDROGEN ION CONCENTRATIONS IN ARTERIAL BLOOD DURING PREGNANCY
    BLECHNER, JN
    COTTER, JR
    STENGER, VG
    HINKLEY, CM
    PRYSTOWS.H
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1968, 100 (01) : 1 - &