Non-invasive in vitro NAM for the detection of reversible and irreversible eye damage after chemical exposure for GHS classification purposes (ImAi)

被引:0
作者
Knetzger, Nicola [1 ]
Ertych, Norman [2 ]
Burgdorf, Tanja [2 ]
Beranek, Joelle [2 ]
Oelgeschlaeger, Michael [2 ]
Waechter, Jana [3 ]
Horchler, Annika [3 ]
Gier, Stefanie [3 ]
Windbergs, Maike [3 ]
Fayyaz, Susann [4 ]
Grimm, Fabian A. [4 ]
Wiora, Georg [5 ]
Lotz, Christian [1 ,6 ]
机构
[1] Fraunhofer Inst Silicate Res ISC, Translat Ctr Regenerat Therapies TLC RT, Rontgenring 12, D-97070 Wurzburg, Germany
[2] German Fed Inst Risk Assessment BfR, German Ctr Protect Lab Anim Bf3R, Dept Expt Toxicol & ZEBET, Berlin, Germany
[3] Goethe Univ Frankfurt GU, Inst Pharmaceut Technol, Frankfurt, Germany
[4] Clariant Prod Deutschland GmbH, Frankfurt, Germany
[5] Courage Khazaka Elect GmbH CK, Cologne, Germany
[6] Univ Hosp Wurzburg, Tissue Engn & Regenerat Med TERM, Wurzburg, Germany
关键词
Eye irritation; NAM; Non-invasive; Impedance spectroscopy; HAZARD IDENTIFICATION; IRRITATION; SELECTION;
D O I
10.1007/s00204-024-03940-x
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
The potential risk of chemicals to the human eye is assessed by adopted test guidelines (TGs) for regulatory purposes to ensure consumer safety. Over the past decade, the Organization for Economic Co-operation and Development (OECD) has approved new approach methodologies (NAMs) to predict chemical eye damage. However, existing NAMs remain associated with limitations: First, no full replacement of the in vivo Draize eye test due to limited predictability of severe/mild damage was reached. Second, the existing NAMs do not allow reliable differentiation between reversible and irreversible eye damage. Especially the prediction of tissue recovery remains challenging in vitro. Existing in vitro NAMs are based on destructive analysis with no consideration of tissue recovery. In this study, we developed a standalone eye-irritation test method based on non-invasive impedance spectroscopy (ImAi) to discriminate between damaging and irritating chemicals. Tissue effects were analyzed via transepithelial electrical resistance (TEER) measurements of human in vitro epithelial models over 14 days. The TEER was performed using a developed impedance spectrometer. For development of the EIT, a chemical reference list of 329 chemicals was compiled. The applicability of the ImAi-test was exemplified by the discrimination of Cat. 1 vs. Cat. 2 for 23 reference chemicals. Correct classification was achieved for 90.9% of Cat. 1 and 83.3% of Cat. 2 chemicals. Our non-invasive in vitro test overcomes the limitations of Cat. 2 classification of the existing in vitro methods and provides for the first time a non-animal test method that can fully replace the Draize eye test.
引用
收藏
页码:1011 / 1028
页数:18
相关论文
共 51 条
[21]   Development of the EpiOcular™ Eye Irritation Test for Hazard Identification and Labelling of Eye Irritating Chemicals in Response to the Requirements of the EU Cosmetics Directive and REACH Legislation [J].
Kaluzhny, Yulia ;
Kandarova, Helena ;
Hayden, Patrick ;
Kubilus, Joseph ;
d'Argembeau-Thornton, Laurence ;
Klausner, Mitchell .
ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2011, 39 (04) :339-364
[22]   Reepithelialization in focus: Non-invasive monitoring of epidermal wound healing in vitro [J].
Kiesewetter, Lisa ;
Littau, Laura ;
Walles, Heike ;
Boccaccini, Aldo R. ;
Groeber-Becker, Florian .
BIOSENSORS & BIOELECTRONICS, 2019, 142
[23]   Same-chemical comparison of nonanimal eye irritation test methods: Bovine corneal opacity and permeability, EpiOcular™, isolated chicken eye, ocular Irritection®, OptiSafe™, and short time exposure [J].
Lebrun, Stewart ;
Nguyen, Linda ;
Chavez, Sara ;
Chan, Roxanne ;
Le, Debby ;
Minh Nguyen ;
Jester, James, V .
TOXICOLOGY IN VITRO, 2021, 72
[24]   Modeling the antioxidant properties of the eye reduces the false-positive rate of a nonanimal eye irritation test (OptiSafe) [J].
Lebrun, Stewart J. ;
Chavez, Sara ;
Chan, Roxanne ;
Nguyen, Linda ;
Jester, James, V .
TOXICOLOGY IN VITRO, 2021, 76
[25]   Cell barrier characterization in transwell inserts by electrical impedance spectroscopy [J].
Linz, Georg ;
Djeljadini, Suzana ;
Steinbeck, Lea ;
Koese, Gurbet ;
Kiessling, Fabian ;
Wessling, Matthias .
BIOSENSORS & BIOELECTRONICS, 2020, 165 (165)
[26]   Real-time measurement of the trans-epithelial electrical resistance in an organ-on-a-chip during cell proliferation [J].
Liu, Jinlong ;
Zhao, Wenjie ;
Qin, Meiyan ;
Luan, Xiaofeng ;
Li, Yuang ;
Zhao, Yang ;
Huang, Chengjun ;
Zhang, Lingqian ;
Li, Mingxiao .
ANALYST, 2023, 148 (03) :516-524
[27]   Utilization of ex vivo tissue model to study skin regeneration following microneedle stimuli [J].
Liu, Xue ;
Barresi, Rebecca ;
Kaminer, Michael ;
Qian, Kun ;
Thillou, Fabienne ;
Bataillon, Michel ;
Liao, I-Chien ;
Zheng, Qian ;
Bouez, Charbel .
SCIENTIFIC REPORTS, 2022, 12 (01)
[28]   Replacing the Draize eye test: Impedance spectroscopy as a 3R method to discriminate between all GHS categories for eye irritation [J].
Lotz, C. ;
Kiesewetter, L. ;
Schmid, F. F. ;
Hansmann, J. ;
Walles, H. ;
Groeber-Becker, F. .
SCIENTIFIC REPORTS, 2018, 8
[29]   The last resort requirement under REACH: From principle to practice [J].
Macmillan, Donna S. ;
Bergqvist, Anders ;
Burgess-Allen, Eleanor ;
Callan, Ian ;
Dawick, James ;
Carrick, Benjamin ;
Ellis, Graham ;
Ferro, Roberto ;
Goyak, Katy ;
Smulders, Chantal ;
Stackhouse, Ricky A. ;
Troyano, Espe ;
Westmoreland, Carl ;
Ramon, Blanca Serrano ;
Rocha, Vanessa ;
Zhang, Xiaoling .
REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2024, 147
[30]   Human skin explant model for the investigation of topical therapeutics [J].
Neil, Jessica E. ;
Brown, Marc B. ;
Williams, Adrian C. .
SCIENTIFIC REPORTS, 2020, 10 (01)