Direct multi-element analysis of biological samples in dry matrix spots by PIXE

被引:1
|
作者
Krmpotic, Matea [1 ]
Telkhozhayeva, Madina [2 ]
Tsubery, Merav Nadav [3 ]
Goldenberg-Cohen, Nitza [4 ]
Girshevitz, Olga [2 ]
机构
[1] Rudjer Boskovic Inst, Div Expt Phys, Zagreb 10000, Croatia
[2] Bar Ilan Univ, Bar Ilan Inst Nanotechnol & Adv Mat, IL-5290002 Ramat Gan, Israel
[3] Bar Ilan Univ, Dept Chem, IL-5290002 Ramat Gan, Israel
[4] Technion Israel Inst Technol, Rappaport Fac Med, Krieger Eye Res Lab, Haifa, Israel
关键词
Dried matrix spots; PIXE; Blood; Serum; Plasma; DRIED BLOOD SPOTS; DROPLET LASER-ABLATION; FILTER-PAPER; MULTIPLE ELEMENTS; QUANTIFICATION; SPECTROMETRY; LEAD; MS;
D O I
10.1016/j.talanta.2024.127394
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The dried matrix spot (DMS) method, initially developed for neonatal blood screening, has gained prevalence in various research fields for its efficiency in handling small sample volumes and its adaptability to diverse analytical techniques. This study presents the results of the first systematic investigation of direct multi-element analysis in DMS of human blood and plasma samples with Particle Induced X-ray Emission (PIXE). Internal standard addition was used to address the issue of DMS heterogeneity and to eliminate the need for determining the sample volume equivalent, allowing a single-spot (single-punch) measurement. The method was tested for linearity, accuracy, precision and limit of detection (LOD) using reference materials. It was applied to samples from healthy volunteers and compared to analysis results obtained by ICP-OES showing good agreement. Sample volumes as low as 50 mu L were sufficient for the quantification of Na, Mg, P, S, K, Ca, Fe, and Zn in whole blood, and Na, Mg, P, S, K, and Ca in plasma samples without significant matrix effects being observed. Chlorine, which is also an electrolyte element present in high enough concentrations for determination by PIXE, was not addressed in this study due to a lack of reference materials. The results highlight PIXE as a viable alternative to other techniques that are sensitive to matrix issues, require larger sample volumes and/or sample treatment. Overall, this work establishes DMS sampling as being suitable for direct multi-element analysis of biological samples by PIXE, offering detection limits at the mg/L level which is sufficient for determination of electrolyte and essential trace elements and paving the way for its broader application in clinical and research settings.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] MULTI-ELEMENT PROTON-INDUCED X-RAY-EMISSION (PIXE) ANALYSIS OF MOLLUSCAN HEARTS
    KOCH, RA
    COURTNEY, WJ
    KAUFMANN, HC
    GREENBERG, MJ
    AMERICAN ZOOLOGIST, 1976, 16 (02): : 256 - 256
  • [22] PIXE application for multi-element analysis of marine micro-algae and measurement of the concentration factor of zinc
    Iwata, Y
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2001, 249 (02) : 343 - 348
  • [23] PIXE application for multi-element analysis of marine micro-algae and measurement of the concentration factor of zinc
    Y. Iwata
    Journal of Radioanalytical and Nuclear Chemistry, 2001, 249 : 343 - 348
  • [24] CONTRIBUTION TO THE PREPARATION OF TRACE CONCENTRATE TARGETS FOR PIXE MULTI-ELEMENT ANALYSIS .2. EXAMPLES OF APPLICATION
    BRUGGERHOFF, S
    JACKWERTH, E
    RAITH, B
    DIVOUX, S
    GONSIOR, B
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1983, 316 (02): : 221 - 226
  • [25] QUANTITATIVE-ANALYSIS OF MULTI-ELEMENT SAMPLES WHEN MEASURED INTENSITIES ARE BIASED
    BIRKS, LS
    X-RAY SPECTROMETRY, 1981, 10 (03) : 152 - 153
  • [26] Comparison of two wet digestion procedures for multi-element analysis of plant samples
    Oliva, SR
    Raitio, H
    Mingorance, MD
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 2003, 34 (19-20) : 2913 - 2923
  • [27] Prompt gamma neutron activation analysis for multi-element measurement with series samples
    Yang, J. B.
    Yang, Y. G.
    Li, Y. J.
    Tuo, X. G.
    Li, Z.
    Cheng, Y.
    Mou, Y. F.
    Huang, W. Q.
    LASER PHYSICS LETTERS, 2013, 10 (05)
  • [28] LEAD SOURCE IDENTIFICATION BY MULTI-ELEMENT ANALYSIS OF DIURNAL SAMPLES OF AMBIENT AIR
    WESOLOWSKI, JJ
    JOHN, W
    KAIFER, R
    ADVANCES IN CHEMISTRY SERIES, 1973, (123): : 1 - 16
  • [29] MULTI-ELEMENT TRACE ANALYSIS OF TUNGSTEN
    SCHERER, V
    HIRSCHFELD, D
    MIKROCHIMICA ACTA, 1987, 1 (1-6) : 261 - 268
  • [30] MULTI-ELEMENT ANALYSIS OF FRUIT KERNELS
    FURR, AK
    PARKINSON, TF
    BACHE, CA
    GUTENMANN, WH
    PAKKALA, IS
    STOEWSAND, GS
    LISK, DJ
    NUTRITION REPORTS INTERNATIONAL, 1979, 20 (06): : 841 - 844