Direct multi-element analysis of biological samples in dry matrix spots by PIXE

被引:1
作者
Krmpotic, Matea [1 ]
Telkhozhayeva, Madina [2 ]
Tsubery, Merav Nadav [3 ]
Goldenberg-Cohen, Nitza [4 ]
Girshevitz, Olga [2 ]
机构
[1] Rudjer Boskovic Inst, Div Expt Phys, Zagreb 10000, Croatia
[2] Bar Ilan Univ, Bar Ilan Inst Nanotechnol & Adv Mat, IL-5290002 Ramat Gan, Israel
[3] Bar Ilan Univ, Dept Chem, IL-5290002 Ramat Gan, Israel
[4] Technion Israel Inst Technol, Rappaport Fac Med, Krieger Eye Res Lab, Haifa, Israel
关键词
Dried matrix spots; PIXE; Blood; Serum; Plasma; DRIED BLOOD SPOTS; DROPLET LASER-ABLATION; FILTER-PAPER; MULTIPLE ELEMENTS; QUANTIFICATION; SPECTROMETRY; LEAD; MS;
D O I
10.1016/j.talanta.2024.127394
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The dried matrix spot (DMS) method, initially developed for neonatal blood screening, has gained prevalence in various research fields for its efficiency in handling small sample volumes and its adaptability to diverse analytical techniques. This study presents the results of the first systematic investigation of direct multi-element analysis in DMS of human blood and plasma samples with Particle Induced X-ray Emission (PIXE). Internal standard addition was used to address the issue of DMS heterogeneity and to eliminate the need for determining the sample volume equivalent, allowing a single-spot (single-punch) measurement. The method was tested for linearity, accuracy, precision and limit of detection (LOD) using reference materials. It was applied to samples from healthy volunteers and compared to analysis results obtained by ICP-OES showing good agreement. Sample volumes as low as 50 mu L were sufficient for the quantification of Na, Mg, P, S, K, Ca, Fe, and Zn in whole blood, and Na, Mg, P, S, K, and Ca in plasma samples without significant matrix effects being observed. Chlorine, which is also an electrolyte element present in high enough concentrations for determination by PIXE, was not addressed in this study due to a lack of reference materials. The results highlight PIXE as a viable alternative to other techniques that are sensitive to matrix issues, require larger sample volumes and/or sample treatment. Overall, this work establishes DMS sampling as being suitable for direct multi-element analysis of biological samples by PIXE, offering detection limits at the mg/L level which is sufficient for determination of electrolyte and essential trace elements and paving the way for its broader application in clinical and research settings.
引用
收藏
页数:9
相关论文
共 37 条
  • [21] Energy dispersive X-ray fluorescence spectrometry for the direct multi-element analysis of dried blood spots
    Margui, E.
    Queralt, I.
    Garcia-Ruiz, E.
    Garcia-Gonzalez, E.
    Rello, L.
    Resano, M.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 139 : 13 - 19
  • [22] What a drop can do: Dried blood spots as a minimally invasive method for integrating biomarkers into population-based research
    Mcdade, Thomas W.
    Williams, Sharon
    Snodgrass, J. Josh
    [J]. DEMOGRAPHY, 2007, 44 (04) : 899 - 925
  • [23] Use of filter paper for the collection and analysis of human whole blood specimens
    Mei, JV
    Alexander, JR
    Adam, BW
    Hannon, WH
    [J]. JOURNAL OF NUTRITION, 2001, 131 (05) : 1631S - 1636S
  • [24] Optimisation of Almeria-type greenhouse ventilation performance with computational fluid dynamics
    Molina-Aiz, FD
    Valera, DL
    Peña, AA
    Gil, JA
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SUSTAINABLE GREENHOUSE SYSTEMS, VOLS 1 AND 2, 2005, (691): : 433 - 440
  • [25] Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks
    Nischkauer, Winfried
    Vanhaecke, Frank
    Bernacchi, Sebastien
    Hervvig, Christoph
    Limbeck, Andreas
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 101 : 123 - 129
  • [26] A critical review of the analysis of dried blood spots for characterizing human exposure to inorganic targets using methods based on analytical atomic spectrometry
    Parsons, Patrick J.
    Galusha, Aubrey L.
    Cui, Yuxia
    Faustman, Elaine M.
    Falman, Jill C.
    Meeker, John D.
    Kannan, Kurunthachalam
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (10) : 2092 - 2112
  • [27] Liquid Wicking in a Paper Strip: An Experimental and Numerical Study
    Patari, Subhashis
    Mahapatra, Pallab Sinha
    [J]. ACS OMEGA, 2020, 5 (36): : 22931 - 22939
  • [28] Pawly J., 2019, PeerJ Analytical Chemistry, V1, pe1, DOI [10.7717/peerj-achem.1, DOI 10.7717/PEERJ-ACHEM.1]
  • [29] Quantification of multiple elements in dried blood spot samples
    Pedersen, Lise
    Andersen-Ranberg, Karen
    Hollergaard, Mads
    Nybo, Mads
    [J]. CLINICAL BIOCHEMISTRY, 2017, 50 (12) : 703 - 709
  • [30] Development of dried serum spot sampling techniques for the assessment of trace elements in serum samples by LA-ICP-MS
    Pilar Chantada-Vazquez, Maria
    Moreda-Pineiro, Jorge
    Cantarero-Roldan, Alicia
    Bermejo-Barrera, Pilar
    Moreda-Pineiro, Antonio
    [J]. TALANTA, 2018, 186 : 169 - 175